FMI FVF30PW - Manual
FMI FVF30PW – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – DANGER: Carbon monoxide; Carbon Monoxide Poisoning:; WARNING: Any change to; WARNINGS
- Page 3 – OWNER’S MANUAL; LOCAL CODES; Where listed vented decorative logs; OPERATION; Figure 1 - Product Identification; Control Knob; UNPACKING; CAUTION: Do not remove the; Continued
- Page 4 – Unusually Tight Construction; per
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Ventilation Air From Outdoors; Do not provide openings for; Figure 3 - Ventilation Air from Outdoors
- Page 7 – LOG SIZING REQUIREMENTS; MINIMUM FIREPLACE; INSTALLATION; CHECK GAS TYPE; A. Clearances from the side of the fireplace; *Minimum 16 inches from Side Wall
- Page 8 – If Not Using Mantel; If using a mantel, proceed to If Using; Noncombustible; Noncombustible material OK.; Installing Damper; If Using Mantel; If you cannot meet these
- Page 9 – Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; flue damper open; FLOOR CLEARANCES; A. If installing appliance on the floor level,; Hearth
- Page 10 – Installation Items Needed; Fitting; Area of Various Standard; Figure 10 - Attaching Damper Clamp; Damper
- Page 11 – WARNING: A qualified service; CAUTION: Avoid damage to; External Regulator
- Page 12 – Figure 15 - Equipment Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.; Figure 14 - Gas Connection; * Minimum inlet pressure for purpose of input adjustment.
- Page 13 – Figure 16 - Checking Gas Joints; INSTALLING LOGS; Make sure log does not; One Piece Log Set; CAUTION: After installation; Items Included for Installation; • Switch; Connecting to Log Set; WARNING: Do not connect; The wire may be shortened; Figure 17 - Connecting the Wire Terminals; Wall Switch
- Page 14 – FOR YOUR SAFETY; • If fireplace has glass doors,
- Page 15 – Pilot Burner; CAUTION: Do not try to adjust; Shutting Off Heater; Lighting; Do not leave the se-; GHRC Series Operation:
- Page 16 – Figure 24 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; BURNER PRIMARY AIR HOLES; GHRCTA Series Operation:; • In the AUTO mode, the thermostat
- Page 17 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 18 – OBSERVED PROBLEM; nance, page 20) or replace burner orifice
- Page 19 – IMPORTANT
- Page 20 – PARTS UNDER WARRANTY; LOGS; Figure 27 - Pilot Inlet Air Hole
- Page 21 – SPECIFICATIONS; Remote Ready; ACCESSORIES; When Gas Pressure Is Too Low; FIREPLACE HOOD; WIRING DIAGRAM; Note
- Page 23 – PARTS LIST; KEY
- Page 24 – NOT A UPC; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
Heat Majic™
Models FVF18PW,
FVF24PW, and
FVF30PW (Millivolt)
Remote Ready
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
PIL
O T
O
F
F
O
N
LO
OFF
ON
AUTO
HI
Save this manual for future reference.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
Patent Pending
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 105194 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu,with headaches, dizziness, or nausea. If youhave these signs, t...
3 105194 OWNER’S MANUAL AUT O OF F ON O F F P IL OT O N H I L O H I L O PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANSI Z223.1/NFPA 54*. *Available from: American Nationa...
4 105194 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code ANSI Z223.1/NFPA 54, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilat...