Fluke 80 Series III - Manual

Fluke 80 Series III

Fluke 80 Series III – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
Page: / 58

Table of Contents:

  • Page 2 – Lifetime Limited Warranty
  • Page 3 – Table of Contents; Title
  • Page 4 – Users Manual; ii
  • Page 5 – iii; List of Tables; Table
  • Page 6 – iv
  • Page 7 – List of Figures; Figure Title
  • Page 9 – Introduction; Warning; This meter complies with:; Warning; identifies conditions and; Caution; Warning
  • Page 10 – Table 1. International Electrical Symbols
  • Page 12 – To protect yourself, use the following guidelines:; Your Meter’s Features; Terminal; mA; Input for 0; COM; NA; eG
  • Page 13 – mV; ReE
  • Page 17 – AUTO
  • Page 18 – nS; Percent. Used for duty cycle measurements.
  • Page 19 – Number; Displays the currently selected range.
  • Page 20 – Input AlertTM Feature; If a test lead is plugged into the mA/; Placing the probes across (in; Making Measurements; Measuring AC and DC Voltage
  • Page 21 – Switch Box; Figure 2. Measuring AC and DC Voltage
  • Page 22 – Testing for Continuity; Press
  • Page 23 – Figure 3. Testing for Continuity
  • Page 24 – Measuring Resistance; The meter’s resistance ranges are 400
  • Page 25 – Circuit Power; OFF; In-Circuit Resistance Measurements; Isolating a Potentiometer; Disconnect; Isolating a Resistor; Figure 4. Measuring Resistance
  • Page 26 – Measuring Capacitance
  • Page 27 – Figure 5. Measuring Capacitance
  • Page 29 – Testing Diodes; Forward Bias; Figure 6. Testing a Diode
  • Page 30 – Measuring AC or DC Current
  • Page 31 – Current through one component; Figure 7. Measuring Current
  • Page 33 – Measuring Frequency; switches the
  • Page 34 – ReEG
  • Page 35 – Measuring Duty Cycle; Trigger Point; Figure 8. Components of Duty Cycle Measurements
  • Page 36 – Determining Pulse Width; a second time to measure the signal’s; Analog Bar Graph; Model 87 Bar Graph
  • Page 37 – s and 100 ms MIN MAX modes.
  • Page 38 – MIN MAX Recording Mode
  • Page 39 – Table 8. MIN MAX Functions; s response time. (The 250 μs response time is
  • Page 40 – Relative Mode; Selecting relative mode (
  • Page 41 – Uses for the Zoom Mode (Models 83 and 85); Maintenance; General Maintenance
  • Page 42 – Testing the Fuses; to; Figure 9. Testing the Current Fuses
  • Page 43 – Replacing the Battery; Replacing the Fuses
  • Page 44 – Service and Parts
  • Page 45 – Figure 10. Battery and Fuse Replacement
  • Page 47 – Figure 11. Replaceable Parts
  • Page 48 – Alligator Clips for use with TL75 test lead set
  • Page 49 – Specifications; Maximum Voltage between any Terminal and Earth Ground:
  • Page 50 – Table 11. Models 85 and 87 AC Voltage Function Specifications; Function
  • Page 51 – Table 12. Model 83 AC Voltage Function Specifications
  • Page 53 – Table 14. Current Function Specifications; Accuracy
  • Page 55 – Table 15. Capacitance and Diode Function Specifications
  • Page 56 – Table 17. Frequency Counter Sensitivity and Trigger Levels; Approximate Trigger Level
  • Page 57 – Table 18. Electrical Characteristics of the Terminals
  • Page 58 – Table 19. MIN MAX Recording Specifications; Model
Loading the manual

®

80 Series III

Multimeters



Users Manual

October 1997 Rev.5, 12/03

1997-2003 Fluke Corporation, All rights reserved.

All product names are trademarks of their respective companies.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Lifetime Limited Warranty

Lifetime Limited Warranty Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used herein,“lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years ...

Page 3 - Table of Contents; Title

i Table of Contents Title Page Introduction.................................................................................................................... 1 Safety Information ......................................................................................................... 1 Your Meter’...

Page 4 - Users Manual; ii

80 Series III Users Manual ii Analog Bar Graph .......................................................................................................... 28 Model 87 Bar Graph .................................................................................................. 28Models 83 and 85 Bar Gr...

Other Fluke Models

All Fluke Other