I N S T A L L A T I O N I N S T R U C T I O N

P R O D U C T D I M E N S I O N S

PLEASE READ THE ENTIRE INSTRUCTIONS BEFORE INSTALLING THE CANOPY

Ti ta n C a n o p y

8 8 7 9 5 ( U K )

R H 3 6 1
R H 3 6 1 M
R H 3 6 1
R H 3 6 1 M

8 8 7 9 6 ( U K )
8 7 9 7 8 ( N Z / A U S )
8 7 9 7 9 ( N Z / A U S )

914mm (36”)

364mm

(14 ~ 5/16”)

320mm

(12 ~ 5/8”)

465mm

(18 ~ 5/16”)

min 615mm

(24 ~ 3/16”)

max 895mm

(35 ~ 1/4”)

120mm

(4 ~ 3/4”)

565mm (22 ~ 1/4”)

a ) Switch off the power to rangehood.
b ) U s e a s m a l l b l a d e d s c r e w d r i v e r t o p r i s e o ff t h e l i g h t c o v e r.
c ) U s e a c l o t h t o r e m o v e t h e b u l b . D o n o t t o u c h t h e b u l b w i t h

fingers.

d ) Replace with a new bulb using a cloth. Do not touch the bulb

with fingers. “Snap” the cover back in place.

e ) Halogen bulb 12Volt/20Watt required.

104735 issue E
ECN: 04 101

For other accessories, parts or service, please contact your local supplier
(Refer to the Warranty Certificate).

BULB

CONTROL PANEL

LIGHT REPLACEMENT

I

I I

I I I

Fan On/Off

Mid Speed

High Speed Delay Switch

Light On/Off

Delay switch - Fan will remain on at low, mid or high speed for 5 mins. before
switching off automatically.

MANUFACTURED FOR

BY:

ROBINH O O D LIMITED

6 ZELANIAN DRIVE, EAST TAMAKI

AUCKLAND, NEW ZEALAND

ISO9001 Certified

E l e c t r i c a l R a t i n g :
3 4 6 W ( 1 . 4 4 A )
M a x a t 2 3 0 - 2 4 0 V 5 0 H z

WARNINGS

C a r e s h o u l d b e ta k e n w h e n r e m o v i n g f i l t e r s i n o r d e r t o p r e v e n t t h e f i l t e r
f a l l i n g a n d c a u s i n g d a m a g e t o t h e h o b t o p .

R e m o v e t r a n s p o r t ta p e f r o m t h e l i g h ts a n d f i l t e r s b e f o r e u s e .

This appliance is not intended for use by young children or infirm persons without
supervision.

Young children should be supervised to ensure that they do not play with the
appliance.

U p o n i n s ta l l a t i o n t h e a p p l i a n c e m u s t b e p o s i t i o n e d s o t h a t t h e p l u g i s
accessible.

There should be adequate ventilation of the room when the rangehood is used at
the same time as appliances burning gas or other fuels.

You must read the details concerning the method and frequency of cleaning.

There is a fire risk if cleaning is not carried out in accordance with the instructions.

Do not flambé under the rangehood.

Exhaust air must not be discharged into an existing flue used for exhausting
fumes from appliances burning gas or other fuels.

The recomended minimum distance between the hob surface and the lowest part
of the rangehood is 610mm (24”). This should be increased to at least 660mm
(26”) (preferably 685mm (27”)) if installed over a gas hob.

Attention should be given to ensure that any applicable regulations concerning
the discharge of exhaust air is fulfilled.

If the supply cord of this equipment is damaged, it must only be replaced by the
manufacturer or it’s service agent, or a similarly qualified person in order to
avoid a hazard.

C a r e s h o u l d b e ta k e n w h e n s e r v i c i n g t h e l i g h t pa n e l d u e t o a s h o r t
s w i t c h w i r e .