First Alert UL217 - Manual

First Alert UL217

First Alert UL217 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
Page: / 11

Table of Contents:

  • Page 2 – INSTALLATION; WHERE TO INSTALL THIS ALARM; Recommended Placement; WHERE THIS ALARM SHOULD NOT BE INSTALLED; AVOIDING DEAD AIR SPACES
  • Page 3 – BEFORE YOU BEGIN INSTALLATION; • Make sure the alarm is not receiving excessively noisy power.; HOW TO INSTALL THIS SMOKE/CO ALARM; PARTS OF THIS SMOKE/CO ALARM
  • Page 4 – Compatible Interconnected Units; INSTALLATION, Continued
  • Page 5 – Tools you will need: • Needle-nose pliers or utility knife; USING THE OPTIONAL LOCKING FEATURES; THE BATTERY COMPARTMENT LOCK; TO LOCK THE BATTERY COMPARTMENT:; THE MOUNTING BRACKET LOCK; TO UNLOCK THE BATTERY COMPARTMENT:
  • Page 6 – HOW YOUR SMOKE/CO ALARM WORKS; THE COVER OF YOUR SMOKE/CO ALARM; WHAT TO DO IF CARBON MONOXIDE IS DETECTED; IF YOUR SMOKE/CO ALARM SOUNDS; WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM
  • Page 7 – WEEKLY TESTING; • NEVER use an open flame of any kind to test this unit. You; REGULAR MAINTENANCE; WHAT TO DO IN CASE OF FIRE
  • Page 8 – WHAT LEVELS OF CO CAUSE AN ALARM?; WHAT YOU NEED TO KNOW ABOUT CO; SYMPTOMS OF CO POISONING
  • Page 9 – REGULATORY INFORMATION FOR SMOKE ALARMS; RECOMMENDED LOCATIONS FOR SMOKE ALARMS; AGENCY PLACEMENT RECOMMENDATIONS
  • Page 10 – GENERAL LIMITATIONS OF SMOKE/CO ALARMS; TROUBLESHOOTING GUIDE
  • Page 11 – LIMITED WARRANTY; How to Obtain Warranty Service
Loading the manual

1

INTRODUCTION

Thank you for choosing BRK Brands, Inc. for your Smoke and Carbon
Monoxide Alarm needs. You have purchased a state-of-the-art Smoke &
CO Alarm designed to provide you with early warning of a fire or Carbon
Monoxide. Key features include:
Smoke & Carbon Monoxide Combination Alarm.
One alarm protects
against two deadly household threats.

Intelligent Sensing Technology designed to help reduce unwanted or
nuisance alarms.

Smart Interconnect can be interconnected to BRK Smoke Alarms.
One interconnect wire carries both smoke and CO alarm signals.

Single Button Test/Silence eliminates confusion. Depending on what
mode the alarm is in, pushing the button provides different functions
such as testing the alarm, silencing the alarm, re-testing the alarm
when in silence and clearing the Latching feature.

Latching Alarm Indicator easily identifies initiating alarm even after the
alarm condition has subsided.

Perfect Mount System includes a gasketless base for easy installation
and a new mounting bracket that keeps the alarm secure over a wide
rotation range to allow for perfect alignment.

Dust Cover is included to keep the alarm clean during construction.

Easy Installation/Maintenance features include a large opening in
the mounting bracket for easy access to wiring. A battery pull tab that
keeps the battery fresh until the home is occupied. A Side Load Battery
Drawer allows for easy battery replacement without removing the alarm
from the ceiling or wall.

Improved UV Resistance keeps the alarm from discoloring over time.

All BRK

®

and First Alert

®

Smoke Alarms conform to regulatory

requirements, including UL217 and are designed to detect particles
of combustion. Smoke particles of varying number and size are
produced in all fires.

Ionization technology is generally more sensitive than photo-
electric technology at detecting small particles, which tend to be
produced in greater amounts by flaming fires, which consume

combustible materials rapidly and spread quickly. Sources of these
fires may include paper burning in a wastebasket, or a grease fire in
the kitchen.

Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for

hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.

For maximum protection, use both types of Smoke Alarms on
each level and in every bedroom of your home.

USER’S MANUAL

Smoke & Carbon

Monoxide Alarm

A

AC

C P

Po

ow

we

erre

ed

d S

Sm

mo

ok

ke

e &

&

C

Ca

arrb

bo

on

n M

Mo

on

no

ox

xiid

de

e A

Alla

arrm

m

w

wiitth

h B

Ba

atttte

erry

y B

Ba

ac

ck

k--u

up

p,,

S

Siille

en

nc

ce

e F

Fe

ea

attu

urre

e a

an

nd

d

L

La

attc

ch

h iin

n g

g A

Alla

a rrm

m

Model SC9120B

Input: 120V AC

~

60 Hz, 0.09A

IIM

MP

PO

OR

RT

TA

AN

NT

T!! P

PL

LE

EA

AS

SE

E R

RE

EA

AD

D C

CA

AR

RE

EF

FU

UL

LL

LY

Y A

AN

ND

D S

SA

AV

VE

E

This user’s manual contains important information about your Alarm’s
operation. If you are installing the Alarm for use by others, you must leave
this manual — or a copy of it — with the end user.

Model

SC9120B

Printed in Mexico
M08-0094-006 K1 08/08

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4

Where To Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where This Alarm Should Not Be Installed . . . . . . . . . . . . . . . . . . . .2
Before You Begin Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How To Install This Smoke/CO Alarm . . . . . . . . . . . . . . . . . . . . . .3-4

Using the Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . .5

How Your Smoke/CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . .6

Understanding the Light and Horn Patterns . . . . . . . . . . . . . . . . . . .6

If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . .6-7

What To Do First–Identify the Type of Alarm . . . . . . . . . . . . . . . . . . .6
What To Do if CO is Detected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
What To Do if Smoke is Detected . . . . . . . . . . . . . . . . . . . . . . . . .6-7
“Smart Interconnect” Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
The “Latching Alarm” Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . .8

What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . .8
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . .8
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . .8

Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . . .8-9

Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . .8
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . . . .9
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . .9

General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . .10

Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

© 2008 BRK Brands, Inc. All rights reserved.
Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005
www.brkelectronics.com • www.firstalert.com

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’t let rubbish accumulate.

Keep alarms clean, and test them weekly. Replace alarms immediately
if they are not working properly. Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every
floor, and an additional one in the kitchen. Have fire escape ladders or
other reliable means of escape from an upper floor in case stairs are
blocked.

BASIC SAFETY INFORMATION

• Dangers, Warnings, and Cautions alert you to important

operating instructions or to potentially hazardous situations.
Pay special attention to these items.

• This Smoke/CO Alarm is approved for use in single-family

residences. It is NOT designed for marine or RV use.

• This combination Smoke/Carbon Monoxide Alarm has two

separate alarms. The CO Alarm is not designed to detect fire
or any other gas. It will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
present in other areas. The Smoke Alarm will only indicate the
presence of smoke that reaches the sensor. The Smoke Alarm
is not designed to sense gas, heat or flames.

Continued...

LISTED TO

UL 217

and

UL 2034

STANDARDS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; WHERE TO INSTALL THIS ALARM; Recommended Placement; WHERE THIS ALARM SHOULD NOT BE INSTALLED; AVOIDING DEAD AIR SPACES

2 INSTALLATION WHERE TO INSTALL THIS ALARM Minimum coverage for Smoke Alarms, as recommended by theNational Fire Protection Association (NFPA), is one Smoke Alarm onevery floor, in every sleeping area, and in every bedroom (See“Regulatory Information For Smoke Alarms” for details on the NFPA recomme...

Page 3 - BEFORE YOU BEGIN INSTALLATION; • Make sure the alarm is not receiving excessively noisy power.; HOW TO INSTALL THIS SMOKE/CO ALARM; PARTS OF THIS SMOKE/CO ALARM

BEFORE YOU BEGIN INSTALLATION This unit is designed to be mounted on any standard wiring junctionbox up to a 4-inch (10 cm) size, on either the ceiling or wall. Read“Where to Install This Alarm” and “Where This Alarm Should Not BeInstalled ” before you begin installation. • Make sure the alarm is no...

Page 4 - Compatible Interconnected Units; INSTALLATION, Continued

SPECIAL REQUIREMENTS FOR INTERCONNECTED ALARMS • Failure to meet any of the above requirements could damage the units and cause them to malfunction, removing your protection. • AC and AC/DC Smoke/CO Alarms can be interconnected. Under AC power, all units will alarm when one senses smokeor CO. When p...

Other First Alert Models

All First Alert Other