Extron STP24LC - Manual

Extron STP24LC

Extron STP24LC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

13 April, 2005

110

24 AWG

(7/32)

0.024"

0.61 mm,

Tinned Cu

24 ohms/

1k ft,

79 ohms

1 km

Alum. in

Polyester Foil

with 24 AWG

Tinned Cu

Drain Wire

(100%)

15 ohms/

1k ft,

49 ohms/

1 km

Alum. in

Polyester Foil

with 24 AWG

Tinned Cu

Drain Wire

(100%)

15 ohms/

1k ft,

49 ohms/

1 km

22-173-03 (1000')

STP24LC

1

shielded

twisted

pair

17

1000

304.8

0.061

1.5

7.7

Single:

blue, white

Overall:

0.190 4.83

gray

NEC CM

UL 1581

AWM 2919

75 °C

110

Same as

above

Same as

above

Same as

above

2

shielded

twisted

pairs

1000 304.8

0.070

1.8

NEC CM

UL 1581

AWM 2919

75 °C

22-174-03 (1000')

STP24LC-2

27

12.2

Single:

red, black;

blue, white

Overall:

0.240 6.10

gray

110

24 AWG

(7/32)

0.024"

0.61 mm,

Tinned Cu

24 ohms/

1k ft,

79 ohms

1 km

22-179-03 (1000')

STP24LCP

1

shielded

twisted

pair

14

1000 304.8

0.057

1.4

6.4

Single:

blue, white

Overall:

0.145 3.68

blue

NEC CMP

UL 910

75 °C

110

Same as

above

Same as

above

2

shielded

twisted

pairs

1000 304.8

0.066

1.7

NEC CMP

UL 910

75 °C

22-180-03 (1000')

STP24LC-2P

23

10.4

Single:

red, black;

blue, white

Overall:

0.205 5.21

blue

conductor-

conductor

conductor-

conductor,

connected to

shield

13

43

25

82

conductor-

conductor

conductor-

conductor,

connected to

shield

13

43

25

82

Same as

above

78%

78%

78%

78%

Specifications — STP24LC Cable

Specifications — STP24LC Cable

Part No. (length)

Model

Description

Nominal

Capacitance

Nom.

Vel.

of

Prop.

Shipping
Weights

Standard

Lengths

Conductor

(stranding)

Diameter

Nom. DCR

Shielding
Materials

(% coverage)

Nom. DCR

UL NEC/

C(UL) CEC

UL AWM

Temp.

Nom.

Imp.

(ohms)

No.

of

Cond.

Ft.

m

Nominal

OD

Inch

mm

Nominal

Core OD

Inch

mm

pF/ft

pF/m

Lbs. kg

(1 or 2 pairs) 24 AWG Shielded Twisted Pairs • Aluminum Foil (100%) Shield

Nonplenum Cable

• Gas Injected Foamed HDPE Insulation • Gray PVC Outer Jacket

Plenum Cable

• Gas Injected Foamed FEP Insulation • Blue Flame Retardant PVC Outer Jacket

dB/

100 m

MHz

dB/

100 ft

Nominal

Attenuation

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Extron Models

All Extron Other