Extron RG6 - Manual
Extron RG6 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
24 November, 2008
75
83%
27
18 AWG
(solid)
0.040"
1.02 mm,
Solid Cu
6.6 ohms/
1k ft
22 ohms/
1 km
18 AWG
(solid)
0.040"
1.02 mm,
Solid Cu
6.4 ohms/
1k ft
21 ohms/
1 km
Bonded Alum.
Foil and
Tinned Cu
Braid (95%)
2.4 ohms/
1k ft,
7.9 ohms/
1 km
Alum. Foil and
Tinned Cu
Braid (95%)
2.4 ohms/
1k ft,
7.9 ohms/
1 km
22-098-02 (500')
22-098-03 (1000')
RG6-1
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
-0.3
-0.5
-0.7
-1.0
-1.5
-1.6
-1.9
-2.1
-2.6
-2.8
-3.0
-3.8
-5.0
-5.9
-10.7
-1.0
-1.8
-2.3
-3.3
-5.0
-5.2
-6.2
-6.9
-8.5
-9.2
-9.8
-12.5
-16.4
-19.4
-35.1
-0.2
-0.5
-0.8
-1.2
-1.5
-1.8
-2.1
-2.4
-2.5
-2.7
-3.1
-4.8
-7.3
-7.8
-13.7
-0.8
-1.5
-2.5
-2.9
-3.8
-5.8
-6.9
-7.9
-8.2
-8.9
-10.2
-15.7
-23.9
-25.6
-44.9
1
coax
500 152.4
12.2
58
1000
304.8
0.180 4.57
26.3
Overall:
0.264 6.70
gray
53.1
75
83%
NEC CM
UL 1581
CSA FT-4
75 °C
NEC CMP
UL 910
75 °C
500 152.4
1000 304.8
0.170 4.32
16.2
53.1
16.2
53.1
16.2
22-164-02 (500')
22-164-03 (1000')
RG6-1P
23
1
coax
10.4
46
20.9
5.9
Overall:
0.234
75
83%
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
-0.3
-0.5
-0.8
-1.0
-1.5
-1.8
-2.1
-2.4
-2.7
-2.9
-3.4
-4.6
-6.5
-7.5
-16.9
-0.8
-1.8
-2.5
-3.3
-5.0
-5.8
-6.8
-7.8
-9.0
-9.5
-11.2
-15.0
-21.2
-24.6
-55.4
22-100-02 (500')
RG6-5
175
Same as
above
Same as
above
5
coax
500 152.4
79.4
0.180 4.57
Single:
0.253 6.43
red, green,
blue, black, yellow
Overall:
0.792 20.12
gray
NEC CM
UL 1581
CSA FT-4
75 °C
reflex blue
Min. bend radius: 9.0"
Sweep tested 5 MHz to 1 GHz.
Sweep tested 5 MHz to 1 GHz.
Sweep tested 5 MHz to 1 GHz.
Min. bend radius: 2.5"
Min. bend radius: 4.5"
Specifications — RG6 Cable
Specifications — RG6 Cable
Part No. (length)
Model
Description
dB/
100 m
MHz
Nominal
Capacitance
dB/
100 ft
Nominal
Attenuation
Nom.
Vel.
of
Prop.
Shipping
Weights
Standard
Lengths
Conductor
(stranding)
Diameter
Nom. DCR
Shielding
Materials
(% coverage)
Nom. DCR
UL NEC/
C(UL) CEC
UL AWM
Temp.
Nom.
Imp.
(ohms)
No.
of
Cond.
Ft.
m
Nominal
OD
Inch
mm
Nominal
Core OD
Inch mm
pF/ft pF/m
Lbs. kg
(1 or 5) 18 AWG Coax • Aluminum Foil (100%) + Tinned Copper Braid Shield
Plenum Cable
• Gas-injected Foamed FEP Insulation • Blue Fire-resistant PVC Outer Jacket
Nonplenum Cable
• Gas-injected Foamed Polyethylene Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
Nonplenum Cable
• Gas-injected Foamed Polyethylene Insulation • Gray PVC Outer Jacket
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.