1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – PRELIMINAR; PCM 340 Installation Notes; all wiring; Secure the PCM base plate to the ceiling.; Figure 5 — Install Raco box and plaster ring
  • Page 3 – The four hanging wires should be taut,; Threaded rod installation; The trim piece can be cut to the desired length.; PCM; Figure 7 — Adjust turnbuckles; Attach washer and nut and secure.; Figure 8 — Threaded rod installation
  • Page 4 – 009 Extron Electronics. All rights reserved.; Europe; Asia; Japan; Middle East; Specifications; Drop distances are measured from the bottom of the hanger plate.
Loading the manual

PRELIMINAR

Y

1

PCM 340 Installation Notes

The Extron PCM 340 Drop Ceiling Projector Mount is used for

hanging PoleVault

System AV products and various projectors.

The PCM is installed above the drop ceiling and secures the

adjustable pipe in a pass-through pipe adapter plate. The pipe

then supports the mounting of the Extron PMK 550 and UPB 25

projector bracket.

C

Maximum load for the PCM is 50 lbs (22.7 kg)

.

The key components of the PCM 340 are shown in figure 1.

Also included in the kit are:

4 turnbuckles, 5 lag eye bolts, 5 concrete anchors, 2 cable clamps,

1 safety wire – 15 ft., 2 tie wire – 30 ft., 4 T-frame screws, 2 set screws,

1 location screw, 4 adhesive pads, 11 hole plugs, 1 escutcheon ring,

(1) 25 inch slotted projector pipe with 1 snap-in trim piece.

Installation

N

Refer to local building standards and codes to verify that the

installation will meet the regulatory requirements.

Observe all local and national building and safety codes,

UL requirements, and ADA Accessibility Guidelines.

1. Install the projector to verify the location.

a.

At the predetermined location for the projector,

identify the

ceiling tile and T-frame where the PCM will be installed

.

b.

Remove the ceiling tile, and

mark the projector's maximum

and minimum throw distances

on the T-frame (see figure 2).

N

Refer to the projector manufacturer's manual for details.

c

.

Place the PCM base plate over the T-frame

, between the two

marks. Lightly tighten the T-frame securing screws (which

can be inserted on the inside or outside of the PCM).

d

. Back out the Pipe Adapter set screws on the adapter plate.

Slide the slotted pipe into the adapter

, aligning the holes

in the pipe with those in the adapter (see figure 3). Tighten

the pipe location screw and the set screws to secure the pipe.

e

.

Install the UPB 25 projector bracket

and the projector onto

the end of the pipe. Refer to the

UPB 25 User Manual

for details.

2. Verify the image location.

a

. Turn on the projector, loosen the wing nuts and slide the base plate

and projector left and right, viewing the image to

verify the proper

location for a centered image

.

T

Remember to use the vertical and horizontal offsets when

aligning the projector. Adjust pipe height if needed.
Refer to the projector manual for details.

b.

When image location is verified,

lock down the wing nuts

.

3. Cut the ceiling tile.

a. Mark the location of the PCM base plate

on the T-frame, before

removing it, to aid in replacing it in the correct location

.

T

Mark the screen direction on the back of the tile to help with orientation of the tile when replacing it after cutting.

N

With assistance, carefully remove the UPB 25 with the projector still attached from the slotted pipe.

Remove the slotted pipe.

PCM 340 Installation Notes

Figure 1 — PCM 340 parts

68-1573-01

Rev B

05 09

Align Pipe holes with
location screw holes.

Insert location screw
and secure.

Figure 3 — Insert pipe into adapter

T-frame

X"

Y"

Minimum and
Maximum
Throw Distance Marks

Projector
Front

Figure 2 — Minimum and maximum
throw distances

T-frame
Securing
Screws (4)

1-gang and 2-gang Accessory Mounting
Points (e.g., Power Sockets)

Pipe Adapter Plate
Wing Nuts (4)

Pipe
Adapter

Base
Plate

Pipe Adapter
Set Screws (2)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PRELIMINAR; PCM 340 Installation Notes; all wiring; Secure the PCM base plate to the ceiling.; Figure 5 — Install Raco box and plaster ring

PRELIMINAR Y PCM 340 Installation Note, cont'd 2 PCM 340 Installation Notes b. Measure the distances X and Y (see figure 2) from the inner vertical section of the front and left T-frame runners to the center of the Pipe Adapter Plate. c. Using these dimensions, mark and cut a hole (using a 2 inch ho...

Page 3 - The four hanging wires should be taut,; Threaded rod installation; The trim piece can be cut to the desired length.; PCM; Figure 7 — Adjust turnbuckles; Attach washer and nut and secure.; Figure 8 — Threaded rod installation

PRELIMINAR Y 3 PCM 340 Installation Notes h. Cut appropriate lengths of the supplied tie wire. Loop the wire through the anchors or lag eye bolts and the turnbuckles, then twist the wire around itself at least five times. i. Tighten the turnbuckles by hand (see figure 7), and level the plate so that...

Page 4 - 009 Extron Electronics. All rights reserved.; Europe; Asia; Japan; Middle East; Specifications; Drop distances are measured from the bottom of the hanger plate.

4 PCM 340 Installation Notes © © 2009 Extron Electronics. All rights reserved. Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FA X Extron USA - East +800.633.9876 Inside USA / Canada Only +1.919.863.1794 +1.919.863.1797 FA X Extron Europe +800.3...

Other Extron Models

All Extron Other