Extron MLS 608 D - Manual

Extron MLS 608 D

Extron MLS 608 D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – MLS 608 D Series • Setup Guide (Continued); Twisted Pair (TP) Cable Transmission Distance; do not connect a LAN cable to any MTP or digital video output port.; same spec at 75 Hz; card, and display used in the system.; Maximum Transmission Distance for Digital Signals at 60 Hz
  • Page 3 – CAUTION; DO NOT; Installation and Cabling; Step 1 — Mount the Switcher; Unbalanced Input; Step 3 — Connect MLS 608 D Outputs; • Do not short the “ +” and “
  • Page 4 – Step 4 — Connect Outputs from MTP/HDMI U R; • 38400 baud •1 stop bit • no parity • 8 data bits • no flow control; Step 6 — Connect Power; Optional — Connect the 2-pole power connector (see; Host; NOTE: If you use cable that has
  • Page 5 – Optimizing Video; Setting the Peaking and Level on the MTP/HDMI U R; Adjusting output skew between the; Selecting the MLS 608 D Output Prepeaking; Adjusting level and peaking between the MLS 608 D and the receiver; See page 7
  • Page 6 – Front Panel Features; Front Panel Operation; VOLUME; LED equivalent
  • Page 7 – = Incremental or decremental value in; Using the DSP Configurator; Download; Extron S3 Sales and Technical Support Hotline.; Basic Simple Instruction Set (SIS) Commands
  • Page 8 – Typical Application for MLS 608 D Series, Showing the MLS 608 D SA; Receiver; Extron; MediaLink Switcher; GlobalViewer; Connector and Cable Information; Twisted Pair RJ-45 Cabling; HD15 Pin Locations
Loading the manual

1

MLS 608 D Series • Setup Guide

Rear Panel Features — MLS 608 D and MTP HDMI U R

NOTE:

The MLS 608 D SA, as shown below, is representative of the MLS 608 D Series. It has the maximum number and type of
connectors and features of the three models. The MLS 608 D model lacks the power amplifier output.

The Extron MLS 608 D Series are eight input, multi-format AV switchers with ProDSP

audio

and are able to integrate analog and digital sources. There are three models:

• MLS 608 D (with variable preamp output - no amplifier)

• MLS 608 D MA (with 40 watt 70 volt mono power amplifier)

• MLS 608 D SA (with 2 x 20 watt stereo power amplifier)

This guide allows you to easily and quickly setup and configure your MLS 608 D using step by step instructions. It covers performing
basic operations using the front panel controls and selected Simple Instruction Set (SIS

) commands.

It also gives connection information for the MTP HDMI U R twisted pair receiver, which is supplied with the MLS 608 D Series unit.
See rear cover for a diagram of a typical MLS 608 D application, showing the MLS 608 D SA model.

NOTE:

For full installation, configuration, and operation details for all MLS 608 D models, see the MLS 608 D Series User Guide,
and for complete details on the MTP HDMI U R, see the MTP HDMI U R User Guide, both available at

www.extron.com

.

1

BUFFERED OUTPUT

MTP

+

AUDIO

+12 V OUT

PWR OUT=

12W

2

3

6

L

R

1

L

R

2

L

R

3

L

R

5

L

R

7

L

R

8

1

2

1

2

MIC/LINE

+ 48V

1

2

L

R

L

R

Tx

+12V

Rx

8

4 (MTP)

CONFIGURABLE ANALOG INPUTS

AUDIO INPUTS

AUDIO OUTPUTS

RS-232

HOST

PWR OUT = 7.2 W

DIGITAL OUTPUT

VIDEO + RS-232

ANALOG OUTPUT

DIGITAL INPUTS

5

7

L

R

6

Tx

N/

A

N/

A

Rx

RS-232 INSERT

MLS 608 D SA

100-240V 50/60 Hz

1.2A MAX

1

2

4/8 OHM - 20W x 2

1

4

7

8

5

13

12

11

9

14

MLS 608 D SA

2

3

10

6

Power input

MTP input

RS-232 port (analog side), not used in MLS 608 D system

Digital signal inputs (1 and 2)

RGBHV, RGBS output*

Composite video output*

Digital (HDMI) output

S-video output*

Component video (R-Y, Y, B-Y) output*

RS-232 pass-through connector

Mono audio output

* = Analog outputs

DIGITAL OUTPUT

DIGITAL INPUT

POWER

12V

0.8A MAX

1

2

HDMI

RS-232

PASS THRU

Tx Rx

RGB

VID

Y/C

B-Y

Y

R-Y

ANALOG OUTPUTS

RS-232

Tx Rx

SPARE

MTP INPUT

1

MONO AUDIO

2

MTP/HDMI U R

A

B

C

F

D

A

G

H

E

K

I

J

Pin T568A Wire Color

T568B Wire Color

1

White-green

White-orange

2

Green

Orange

3

White-orange

White-green

4

Blue

Blue

5

White-blue

White-blue

6

Orange

Green

7

White-brown

White-brown

8

Brown

Brown

Power, Analog, and Digital Connections

Audio and RS-232 Connections

a

AC power connector

i

Audio inputs: 5-pole captive screw connectors (inputs 1-3, 5-8)

b

RGB, component/S-video/composite inputs: 15-pin HD

connectors (inputs 1-3, see rear page for pinout details)

j

Mic/line level audio inputs (1-2): 3-pole captive screw connectors

and phantom power LEDs

c

Buffered output: 15-pin HD connector (tied only to input 1)

k

Line level audio output: 5-pole captive screw connectors

(audio outputs 1-2)

d

Universal MTP RJ-45 connector (input 4, see rear page for

pinout details)

l

Power amplifier output connector (MA and SA units only)

e

12 V output MTP/HDMI U R power source: 2-pole captive

screw connector

m

RS-232 control/configuration port and +12 V power output

(for optional MLC power source): 5-pole captive screw connector

f

Analog video and audio MTP output: RJ-45 connector

n

RS-232 insertion pass-through port: 5-pole captive screw connector

g

Digital inputs: HDMI connectors (inputs 5-8)

h

Digital video and RS-232 outputs: RJ-45 connectors

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MLS 608 D Series • Setup Guide (Continued); Twisted Pair (TP) Cable Transmission Distance; do not connect a LAN cable to any MTP or digital video output port.; same spec at 75 Hz; card, and display used in the system.; Maximum Transmission Distance for Digital Signals at 60 Hz

2 MLS 608 D Series • Setup Guide (Continued) Twisted Pair (TP) Cable Transmission Distance CAUTION: Do not connect the MTP cable to any LAN port, telecommunications network, or digital video output port. Likewise, do not connect a LAN cable to any MTP or digital video output port. There are differen...

Page 3 - CAUTION; DO NOT; Installation and Cabling; Step 1 — Mount the Switcher; Unbalanced Input; Step 3 — Connect MLS 608 D Outputs; • Do not short the “ +” and “

3 Unbalanced Output Balanced Output Tip NO Ground Here Sleeve(s) Tip NO Ground Here LR A UDIO Tip Ring Sleeve(s) Tip Ring LR A UDIO CAUTION For unbalanced audio, connectthe sleeve(s) to the ground contact. DO NOT connect the sleeve(s) to the negative (-) contacts. Installation and Cabling Step 1 — M...

Page 4 - Step 4 — Connect Outputs from MTP/HDMI U R; • 38400 baud •1 stop bit • no parity • 8 data bits • no flow control; Step 6 — Connect Power; Optional — Connect the 2-pole power connector (see; Host; NOTE: If you use cable that has

4 MLS 608 D Series • Setup Guide (Continued) RGB VID Y/C B-Y Y R-Y ANALOG OUTPUTS RS-232 Tx Rx SPARE 1 MONO AUDIO 2 Component Video –Connect to these 3 BNCs. Composite Video – Connect to this BNC. RGBHV and RGBS –Connect to this VGAconnector. S-video – Connect to this mini DIN connector. Mono Audio ...

Other Extron Models

All Extron Other