Extron MLC 64 RS VC D - Manual

Extron MLC 64 RS VC D

Extron MLC 64 RS VC D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – MLC 60 Decora Series • Setup Guide (Continued); Change the faceplate, buttons, and volume control knob as; If desired, replace the buttons in the faceplate as follows:; Connect the cables to the rear panel ports.; Connect a display device or switcher to; MLC RS D Rear Panel; Peg; MUTE; Turn Knob to
  • Page 3 – Product Category; Connect a display device, switcher, or up to two IR emitters to; IR Emitter; — The Digital Input port enables you to connect a switch or sensor to; logic low; Wire the volume control module (MLC 64 RS VC D only); Choose an Extron amplifier that is capable of; Rear Panel; A B C
  • Page 4 – 011 Extron Electronics All rights reserved.; Connect and apply power.; all devices in the system.; SECTION A–A; Power Supply; Configure the MLC buttons and ports; MLC 60 Series Configuration; Test the system; to ensure that the MLC is functioning properly.; Mount the MLC to an electrical box or a Decora mounting bracket.; Mount the MLC to a Decora mounting bracket (see the
Loading the manual

Product Category

IMPOR

TANT

:

Go to www

.extron.com for the

complete user guide and installation

instructions befor

e connecting the

product to the power sour

ce.

MLC 60 Series • Setup Guide

for the MLC 62 RS D, MLC 62 IR D, and MLC 64 RS VC D

The MLC 60 D Series are keypad controllers for use
in classrooms and meeting facilities. They mount
to Decora

®

-style wallplates and therefore may be

referred to as “D” models. The controllers have
backlit soft touch buttons and can control common
AV functions, including power, input switching,
and volume. The MLC RS series provides RS-232
serial and IR ports for universal display control. In
addition, a digital input and two relays are included
for monitoring and controlling other systems in the
room. The MLC 64 RS VC D has a volume control
module that lets you raise and lower the volume on
an Extron amplifier with a remote volume control
port, such as the MPA 122 or MPA 401. The MLC 62 IR D provides IR control only. These products mount in one-gang or
two-gang junction boxes and include black and white color options.

NOTES:

Installation and service must be performed by authorized personnel only.

Check that the installation meets the local and state regulatory requirements, including building, electrical,
and safety codes, as well as UL and ADA accessibility requirements.

For full installation, configuration, and operation details, see the

MLC 60 Series User Guide

, available at

www.extron.com

.

Installation Steps

Rx

Tx

GROUND

Tx/IR

COMMON

1

1

2

HOST/

CONFIG

PORT

A

RS-232

PORT

B

IR/

S

DIGITA

L

INPU

T

Tx

PW

R

12

V

0.4 A MA

X

RELAYS

N/

O

GROUND

GROUND

GROUND

GROUND

+12 VDC

Rx

GROUND

IR OUT

HOST/

CONFIG

PORT

A

IR

Tx

PW

R

12V

0.4 A MA

X

GROUND

GROUND

+12 VDC

MLC 62 RS D

MLC 62 IR D

MLC 64 RS VC D

GND

VOL

10V

Rear Panels

Rx

Tx

GROUND

Tx/IR

COMMON

1

1

2

HOST/

CONFIG

PORT

A

RS-232

PORT

B

IR/

S

DIGITAL

INPU

T

Tx

PW

R

12

V

0.4 A MA

X

RELAYS

N/

O

GROUND

GROUND

GROUND

GROUND

+12 VDC

1.

Prepare the installation site.

The MLC 60 D models can be installed in a standard US one-gang or two-gang electrical

wall box or mounting bracket (“mud ring”).

a.

Install the electrical box, following the instructions provided with it, or the provided mounting bracket.

CAUTION:

Ensure that the electrical box is properly grounded.

b.

Prepare and pull the cables through the electrical box or mounting bracket.

1

VOLUME

Extron

DISPLAY

ON

OFF

VIDEO

PC

VOLUME

Extron

DISPLAY

ON

OFF

PC

VIDEO

LAPTOP

MUTE

MLC 62 RS D

MLC 62 IR D

AUX

LAPTOP

PC

MUTE

Extron

DISPLAY

VOLUME

ON

OFF

MUTE

VOLUME

FF

VIDEO

MLC 64 RS VC D

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MLC 60 Decora Series • Setup Guide (Continued); Change the faceplate, buttons, and volume control knob as; If desired, replace the buttons in the faceplate as follows:; Connect the cables to the rear panel ports.; Connect a display device or switcher to; MLC RS D Rear Panel; Peg; MUTE; Turn Knob to

MLC 60 Decora Series • Setup Guide (Continued) 2. Change the faceplate, buttons, and volume control knob as needed. a. (MLC 64 RS VC D only) If changing the faceplate on the MLC 64 volume control module, first remove the volume knob: 1. Rotate the knob until the dot on the knob is aligned with the b...

Page 3 - Product Category; Connect a display device, switcher, or up to two IR emitters to; IR Emitter; — The Digital Input port enables you to connect a switch or sensor to; logic low; Wire the volume control module (MLC 64 RS VC D only); Choose an Extron amplifier that is capable of; Rear Panel; A B C

Product Category z Port B IR/S (RS models) or Port A IR (IR models): Connect a display device, switcher, or up to two IR emitters to this port. On RS models, you can configure Port B IR/S for either serial or IR communication, using the MLC 60 Series configuration program. On IR-only models, Port A ...

Page 4 - 011 Extron Electronics All rights reserved.; Connect and apply power.; all devices in the system.; SECTION A–A; Power Supply; Configure the MLC buttons and ports; MLC 60 Series Configuration; Test the system; to ensure that the MLC is functioning properly.; Mount the MLC to an electrical box or a Decora mounting bracket.; Mount the MLC to a Decora mounting bracket (see the

68-2166-50 Rev. A 11 11 Extron USA - West Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500+1.714.491.1517 FAX Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794+1.919.863.1797 FAX Extron Europe +800.3987.6673 Inside Europe Only +31.33.453.4040+31.33.453.4050 FAX...

Other Extron Models

All Extron Other