Extron MHRVGA - Manual
Extron MHRVGA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
02 December, 2008
59.1
75
83%
26 AWG
(7/34)
0.019"
0.48 mm,
Tinned Cu
41 ohms/
1k ft,
135 ohms
1 km
Same as
above
Same as
above
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
Alum. Foil and
Tinned Cu
Braid (85%)
Alum. Foil and
Tinned Cu
Braid (85%)
Tinned Cu
Braid (85%)
22-024-01 (500')
22-024-03 (1000')
MHRVGA
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
-7.8
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
3
coax
0.076 1.93
0.033 0.84
0.033 0.84
0.033 0.84
0.033 0.84
500
1000
152.4
304.8
Single:
0.105 2.67
red, green, blue
18.0
500 152.4
1000 304.8
NEC CM
UL 1581
CSA FT-4
AWM 2990
VW-1
60 °C
2
shielded
twisted
pairs
7
insulated
conduct-
ors
7
insulated
conduct-
ors
Overall
cable
2
shielded
twisted
pairs
Overall
cable
54
95
24.5
43.1
22-131-02 (500')
22-131-03 (1000')
MHRVGAP
58
26.3
99
44.9
Single:
black & red
black & white
Same as
above
Tinned Cu
Braid (85%)
Single:
black & red
black & white
Single:
blue, green,
violet, grey,
yellow, orange,
brown
Same as
above
Single:
blue, green,
violet, grey,
yellow, orange,
brown
Overall:
0.330 8.39
gray
66%
conductor-
conductor
conductor-
conductor,
connected to
shield
35
115
62
203
54.8
75
81%
26 AWG
(7/34)
0.019"
0.48 mm,
Tinned Cu
41 ohms/
1k ft,
135 ohms
1 km
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
-0.5
-1.1
-1.6
-2.3
-3.6
-4.3
-5.1
-6.0
-7.0
-7.4
-8.8
-11.8
-17.6
-21.4
-51.2
-1.5
-3.7
-5.4
-7.5
-11.8
-14.1
-16.8
-19.7
-23.0
-24.3
-28.8
-38.7
-57.8
-70.1
-168.0
3
coax
0.074 1.88
Single:
0.102 2.60
red, green, blue
16.7
Overall:
0.330 8.38
blue
66%
conductor-
conductor
conductor-
conductor,
connected to
shield
35
115
62
203
NEC CMP
UL 910
75 °C
Sweep tested 5 MHz to 1 GHz.
Min. bend radius: 4.0"
Sweep tested 5 MHz to 1 GHz.
Min. bend radius: 6.0"
Specifications — MHRVGA Cable
Specifications — MHRVGA Cable
Part No. (length)
Model
Description
dB/
100 m
MHz
Nominal
Capacitance
dB/
100 ft
Nominal
Attenuation
Nom.
Vel.
of
Prop.
Shipping
Weights
Standard
Lengths
Conductor
(stranding)
Diameter
Nom. DCR
Shielding
Materials
(% coverage)
Nom. DCR
UL NEC/
C(UL) CEC
UL AWM
Temp.
Nom.
Imp.
(ohms)
No.
of
Cond.
Ft.
m
Nominal
OD
Inch
mm
Nominal
Core OD
Inch mm
pF/ft pF/m
Lbs. kg
Composite Cable: (3) 26 AWG Miniature Coax • (2) 26 AWG Shielded Twisted Pairs • (7) 26 AWG Insulated Conductors
Overall Cable Shield: Aluminum Foil (100%) + Tinned Copper Braid
Nonplenum Cable
• Natural Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
Plenum Cable
• Natural Foamed FEP Insulation • PVC Inner Jackets • Blue Fire-Resistant PVC Outer Jacket
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.