Extron AAP 100 and MAAP 100 Installation Guide
The following procedure is for mounting the AAP 100 and MAAP 100 panels
on hard surfaces (plywood, hardwood, etc.). For soft surfaces (particle
board, drywall, etc.), additional hardware such as anchors may be required
(not provided).
1.
Make a copy of the appropriate full size rough-in template. Cut out the
center portion of the template up to the dashed guidelines.
C
For accurate sizing, copy the template at exactly 100%.
2.
Place the template in the desired location and mark the guidelines for
the opening on the surface.
3.
Carefully cut away the material inside the guidelines. Check the
opening size by placing the panel against the opening.
4.
Cable the AAP(s)/MAAP(s) and install them on the panel.
5.
Place the panel against the surface and mark the locations of the two
wall mounting holes on the surface.
6.
Remove the panel and drill 1/4" deep pilot holes (half the width of the
shaft of the screw) at the marked locations. Replace the panel.
7.
Use two 1/2" (1.3 cm) long, #6 flat headed wood screws (provided) to
fasten the panel directly onto the surface. Hand tighten the screws.
Product Dimensions
68-837-01
Rev. B
08 08
AAP 100 pnl.eps
1.750
2 x 0.875
0.000
0.250
4.250
4.500
0.000
0.100
MAAP 100 pnl.eps
0.000
0.250
3.000
3.250
1.750
2 x 0.875
0.000
0.100
The dashed line indicates the
recommended cut-out area
for the installation surface.
1.5" H x 2.25" W
(3.8 cm H x 5.7 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 3.25" W
(4.45 cm H x 8.25 cm W)
The dashed line indicates the
recommended cut-out area
for the installation surface.
1.5" H x 3.5" W
(3.8 cm H x 8.9 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 4.5" W
(4.45 cm H x 11.4 cm W)
Template for
the AAP 100
Template for
the MAAP 100
Installation Templates
© 2008 Extron Electronics. All rights reserved.
Extron
USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517
FA X
Extron
USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797
FA X
Extron
Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050
FA X
Extron
Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664
FA X
Extron
Japan
+81.3.3511.7655
+81.3.3511.7656
FA X
Extron
China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566
FA X
Extron
Dubai
+971.4.2991800
+971.4.2991880
FA X
The dashed line indicates the
recommended cut-out area
for the installation surface.
1.5" H x 2.25" W
(3.8 cm H x 5.7 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 3.25" W
(4.45 cm H x 8.25 cm W)
The dashed line indicates the
recommended cut-out area
for the installation surface.
1.5" H x 3.5" W
(3.8 cm H x 8.9 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 4.5" W
(4.45 cm H x 11.4 cm W)
Template for
the AAP 100
Template for
the MAAP 100
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.