Specifications — IR Link IR Signal Repeater
Control/remote — IR repeater
IR controller module ................... Extron IR remote controls only
IR output carrier frequency ........ 38 kHz
Use the IR Link with Extron products only.
General
Power ............................................. 12 VDC, 0.21 A supplied by an Extron MLC 206 MediaLink Controller, MediaLink
Switcher (MLS), or external power supply
Temperature/humidity .............. Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Rack mount ................................... No, but furniture/wall mountable
Enclosure type .............................. Metal
Enclosure dimensions
Faceplate (1-gang) .... 4.5" H x 2.8" W x 0.1" D (11.4 cm H x 7.1 cm W x 0.3 cm D) (1 gang)
Circuit board ............ 2.6" H x 1.75" W x 0.8" D (4.1 cm H x 4.4 cm W x 2.0 cm D)
(Depth includes connectors and components.)
Allow at least 1.5" (3.8 cm) depth within the wall box or furniture to accommodate
the circuit board, connectors, and cables.
Product weight ............................. 0.1 lbs (<0.1 kg)
Shipping weight ........................... 1 lb (1 kg)
Vibration ....................................... ISTA 1A in carton (International Safe Transit Association)
Listings .......................................... UL, CUL as a component of the MediaLink Controller (MLC 206)
Compliances ................................. CE, FCC Class A, VCCI, AS/NZS, ICES as a component of the
MediaLink Controller (MLC 206)
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
Specifications are subject to change without notice.