Page 2 - Precautions; Safety Instructions • English
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may pres...
Page 3 - 注意; 声明; FCC Class A Notice
安全须知 • 中文 这个符号提示用户该设备用户手册中有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解 所 有 安 全 和 使 用 说 明 。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 避免追加 • 不要使用该产品厂商没有推荐的工具或 追加设备,以避免危险。 警告 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必 须 使 用 有 地 线 的 供 电 系 统 供 电 ...
Page 4 - This page has been intentionally left blank.
Page 5 - IPI 100 Series, IPI 200 Series • Quick Start Guide; Installation and service must be performed by authorized; disconnect the power cords
IPI 100 Series, IPI 200 Series • Quick Start Guide QS-1 Quick Start Guide — IPI 101, IPI 104 W Installation and service must be performed by authorized personnel only. These products must be used with UL approved, grounded electrical boxes. To install an Extron IP Intercom ® Sytem, follow the steps ...
Page 6 - Quick Start Guide — IPI 101, IPI 104, cont’d; MLC 226 IP User’s Manual
IPI 100 Series, IPI 200 Series • Quick Start Guide Quick Start Guide — IPI 101, IPI 104, cont’d QS-2 Step 7 Install each MLC 226 IP and IPI into the wallboxes you installed in step 2 above. Step 8 Connect the console PC(s) to the network. Step 9 Connect the PC(s) and MLC(s) to power sources and turn...
Page 9 - IPI 100 Series, IPI 200 Series • Table of Contents; Table of Contents
TOC-i IPI 100 Series, IPI 200 Series • Table of Contents Table of Contents Chapter One • Introduction ................................................... 1-1 About this Manual .................................................................... 1-2 Terms used in this manual ............................
Page 10 - Table of Contents, cont’d; Configuration Utility menus; Chapter Five
TOC-ii IPI 100 Series, IPI 200 Series • Table of Contents Table of Contents, cont’d 68-1170-01 C 12 08 All trademarks mentioned in this manual are the properties of their respective owners. Configuring the IPI Intercom System ................................ 4-16 Parts of the Configuration Utility s...
Page 11 - Chapter One; Introduction
IPI 100 Series, IPI 200 Series 1 Chapter One Introduction About this Manual About the MediaLink ™ IP Intercom ® Modules Features System Requirements
Page 12 - IPI 100 Series, IPI 200 Series • Introduction; About this Manual; Terms used in this manual; About the IP Intercom Modules
IPI 100 Series, IPI 200 Series • Introduction Introduction 1-2 About this Manual This manual describes how to configure and operate the following Extron MediaLink ™ IP Intercom ® Modules: • IPI 101 AAP• IPI 104 AAP• IPI 201 Series• IPI 204 Series N The IPI 201 and IPI 204 series include AAP and 2-ga...
Page 14 - Features
IPI 100 Series, IPI 200 Series • Introduction Introduction, cont’d 1-4 Features • Two-way, half-duplex voice communications over an IP network • Compatibility with IP Intercom-enabled MLC 226 IP MediaLink Controllers (IPI 101 AAP and IPI 104 AAP) • Backlit, configurable Push To Talk buttons• Integra...
Page 15 - Chapter Two; Installation
IPI 100 Series, IPI 200 Series 2 Chapter Two Installation UL Requirements Installing or Replacing Button Labels Mounting the IPI 101 or IPI 104 into an AAP Wall Plate or Device Faceplate Mounting the IPI 201 or IPI 204 into an AAP Wall Plate or Device Faceplate IPI Rear Panel Features and Cabling ML...
Page 16 - IPI 100 Series, IPI 200 Series • Installation; UL Requirements
IPI 100 Series, IPI 200 Series • Installation Installation 2-2 W Installation and service must be performed by authorized personnel only. This product should be used with a UL approved electrical box. See “UL Requirements”, below. N The MLC 226 IP to which the IPI intercom is connected must have bee...
Page 18 - IPI 100 AAP, IPI 200 AAP Series • Installation; Mounting the IPI 101 or IPI 104 into an AAP
IPI 100 AAP, IPI 200 AAP Series • Installation Installation, cont’d 2-4 Mounting the IPI 101 or IPI 104 into an AAP Wall Plate or Device Faceplate The IPI intercom and any other adapter plates must be attached to a device faceplate or AAP wall plate and cabled before the device or wall plate is inst...
Page 19 - Mounting the IPI 201 or IPI 204 into an AAP
IPI 100 AAP, IPI 200 AAP Series • Installation 2-5 Mounting the IPI 201 or IPI 204 into an AAP Wall Plate or Device Faceplate The IPI 201 and IPI 204 intercoms must be attached to a device faceplate or AAP wall plate and cabled before the device or wall plate is installed in a wall or furniture. Unl...
Page 20 - IPI Rear Panel Features and Cabling; Intercom port; (IPI 101 AAP and IPI 104 AAP only) — This port
IPI 100 AAP, IPI 200 AAP Series • Installation Installation, cont’d 2-6 IPI Rear Panel Features and Cabling Ä Intercom port (IPI 101 AAP and IPI 104 AAP only) — This port is used for power, control, and voice data communication with the MLC. Plug one end of a standard, straight through, CAT 5, CAT 5...
Page 21 - you choose to terminate your own cable, the cable must be; LAN port; Steps
IPI 100 AAP, IPI 200 AAP Series • Installation 2-7 IPI Rear Panel Features and Cabling Ä Intercom port (IPI 101 AAP and IPI 104 AAP only) — This port is used for power, control, and voice data communication with the MLC. Plug one end of a standard, straight through, CAT 5, CAT 5e, or CAT 6 cable ter...
Page 22 - Audio Out; MLC Audio Connection; The volume for this audio output can be adjusted via; Sample Applications
IPI 100 AAP, IPI 200 AAP Series • Installation Installation, cont’d 2-8 e Audio Out — A 3-pole, 3.5 mm captive screw connector is used for audio output connection. It provides a -10 dBV unbalanced signal that can be connected to local, powered speakers or to any audio or paging system. MLC Audio Con...
Page 24 - cont’d; Connect one or more PCs to the same network and install; Netw
IPI 100 Series, IPI 200 Series • Installation Installation, cont’d 2-10 2. Connect one or more PCs to the same network and install the IP Intercom HelpDesk Software on each PC. Read chapter 4 for instructions on how to install and use the software. TCP/IP Netw ork Straight-through Networ k Ca bl e 5...
Page 25 - Panel to panel mode will only work when both panels are
IPI 100 Series, IPI 200 Series • Installation 2-11 3. Configure the intercoms and set up the intercom list for each console PC. Each console could be set up to monitor a different group of intercoms, but most likely the lists will overlap. In this example, an installation in one building of a colleg...
Page 26 - Intercom with amplifier mode; Remote; Network
IPI 100 AAP, IPI 200 AAP Series • Installation Installation, cont’d 2-12 Intercom with amplifier mode The MLC’s Audio Out 2-pole captive screw connector outputs a -10 dBV audio signal that can be routed to an MPA 122 or any external audio amplifier, then to speakers. 1. Cable the system as shown in ...
Page 27 - TWO WAY IN-WALL LOUDSPEAKER
IPI 100 Series, IPI 200 Series • Installation 2-13 BASS LEVEL TREBLE MINI POWER AMPLIFIER MPA 122 ON OFF LIMITER STEREO DUAL MONO POWER 12V 3A MAX OUTPUTS 4/8 Ohms INPUTS L R L R REMOTE 10VVOL/MUTE L MPA 122 R C US HOST CONTROL R 1=DITIGAL I/O 2=Tx 3=Rx 5=GND 38400, N, 8, 1 PRESS TAB WITH TWEEKER TO...
Page 29 - Chapter Three; Operation; Front Panel Features and Operation
IPI 100 Series, IPI 200 Series 3 Chapter Three Operation Front Panel Features and Operation Button Operation
Page 30 - IPI 100 Series, IPI 200 Series • Operation; Speaker
IPI 100 Series, IPI 200 Series • Operation Operation 3-2 Front Panel Features and Operation a Speaker — This integrated speaker provides mono output at the IPI panel. b Mic On LED — This LED lights under two circumstances: • When a configured Push to Talk button is pressed. • To indicate that someon...
Page 31 - Button Operation; Push to talk operation
IPI 100 Series, IPI 200 Series • Operation 3-3 e Push to Talk button(s) — The IPI 101 AAP and IPI 201 units include one of these buttons, and the IPI 104 AAP and IPI 204 units have four. N The MLC and IPI intercoms must be configured (via software) to associate each button with the IP address of a s...
Page 33 - Chapter Four; Configuration and Control
IPI 100 Series, IPI 200 Series 4 Chapter Four Configuration and Control Software System Requirements Installing the Software Using the Software: an Overview Parts of the Main Screen Main Screen Menus Configuring the IPI Intercom System
Page 34 - IPI 100 Series, IPI 200 Series • Configuration and Control; MLC 226 Series User’s Manual; Software System Requirements
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control 4-2 The IP Intercom ® System can be set up remotely and controlled using the IP Intercom HelpDesk TM software and a host computer (console PC).To function together, the PC must be network-capable with the proper pro...
Page 35 - Using the Software: an Overview; The default administrator password is “; extron; The default user password is “; user; ” (with all lower case
IPI 100 Series, IPI 200 Series • Configuration and Control 4-3 Using the Software: an Overview The software allows configuration access only to administrators to prevent other users from making changes to • HelpDesk preferences• the system configuration including the set of intercoms with which a gi...
Page 36 - Configuration and Control, cont’d; IP Intercom HelpDesk screen before configuration; Listen
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-4 IP Intercom HelpDesk screen before configuration After configuration, the software screen lists the devices to be managed by the console, indicates their status (connected, disconnected, communicating), ...
Page 37 - IP Intercom HelpDesk screen after configuration; Parts of the Main Screen; Each area of the IP Intercom HelpDesk software’s main screen
IPI 100 Series, IPI 200 Series • Configuration and Control 4-5 IP Intercom HelpDesk screen after configuration Parts of the Main Screen Each area of the IP Intercom HelpDesk software’s main screen provides a different set of functions and/or information. Refer to the picture below as a guide to this...
Page 38 - Menu bar; Speaking to an intercom; Talk; Making a group announcement
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-6 a Menu bar — See “Main Screen Menus” on page 4-12 for details on the drop-down menus available here. b Talk Mode area — The Talk Mode section of the IP Intercom HelpDesk is used to speak or play announce...
Page 39 - Only groups containing intercoms are available, the rest
IPI 100 Series, IPI 200 Series • Configuration and Control 4-7 1 . In the Active Intercom List, select an intercom and assign it to a group using the Group drop-down menu in the Group column. After an intercom has been assigned to a group the group number shows in the Group selection area. 2 . Selec...
Page 40 - Exit; Listening to an intercom
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-8 3 . Select an announcement from the Sound Bite Selection window. 4 . Click the Play to Intercom(s) button. 5 . After the announcement is played, repeat the process to send a different message or click th...
Page 41 - Intercom Settings area
IPI 100 Series, IPI 200 Series • Configuration and Control 4-9 2 . Select Reject Calls or Forward Calls . If the Reject Calls option is set, no calls are accepted. The Forward Calls option sends the call to another help desk. 3 . Click Accept Calls to return to the Listening mode. Hands-free operati...
Page 42 - NO INCOMING CALLS
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-10 NO INCOMING CALLS is displayed when no calls are coming into the help desk. INCOMING CALL along with the name and IP address of the calling intercom is displayed when a call is received. LAST INCOMING C...
Page 43 - or; Advanced
IPI 100 Series, IPI 200 Series • Configuration and Control 4-11 Advanced Settings — available in the active intercom list area and from the Intercom menu. 1. Right-click on the intercom’s row and select Advanced Settings . or Select Advanced Settings... from the Intercom menu. If prompted to do so, ...
Page 44 - Status bar; Main Screen Menus; File menu
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-12 To save or clear the activity log, select Activity Log from the Tools menu. Activity logs are saved as text (*.txt) files. i Status bar — The status bar displays general information including the consol...
Page 45 - Intercom menu; These options are also accessed by right-clicking an; Help menu
IPI 100 Series, IPI 200 Series • Configuration and Control 4-13 you can set up or modify an intercom system. • Log off, Log on... — from help desk administrator or user status. Preferences are discussed in “Setting preferences” on page 4-13.” See Configuring the IPI Intercom System“ on page 4-16 for...
Page 46 - Setting preferences; General Options
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-14 Setting preferences 1 . From the main help desk screen, click on the Tools menu and select Preferences . A HelpDesk Preferences dialog box (shown on the next page) appears. 2 . Select the desired settin...
Page 47 - PTT; If more than one intercom is calling the help desk, the pop-
IPI 100 Series, IPI 200 Series • Configuration and Control 4-15 the HelpDesk’s Listen button is first activated or when the intercom user presses a Push to Talk button and connects with a help desk. The intercom plays a 2-tone beep when the Listen button is deactivated or the Push to Talk button is ...
Page 48 - Audio Notification; button; Configuring the IPI Intercom System
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-16 If you click BUSY Answer Later , the intercom plays a message indicating that the support staff is busy. Audio Notification — If you select Audio Notification , when an intercom user presses a button, t...
Page 49 - Parts of the Configuration Utility screen; Configuration Utility menu bar
IPI 100 Series, IPI 200 Series • Configuration and Control 4-17 3 . Add intercoms to the intercom list and click Update Intercom List . 4 . Configure each intercom and click Apply . See the “Configuration” section in this chapter for details. 5 . Exit the configuration utility. The main screen is no...
Page 51 - nortxeStationNotPresent.wav
IPI 100 Series, IPI 200 Series • Configuration and Control 4-19 • Upload the “Station Not Present” Wave File to Intercom — Load the default file named nortxeStationNotPresent.wav to the selected MLC’s or IPI 201/204 series intercoms’ memory. If the intercom user calls the help desk while the interco...
Page 52 - About; Setup procedure; Tools
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-20 • About — Select to see information about the IP Intercom HelpDesk software. Setup procedure Follow the steps below to set up the system. 1 . Double-click on the IPI icon under the Extron group or folde...
Page 53 - Manually by IP Address
IPI 100 Series, IPI 200 Series • Configuration and Control 4-21 Manually by IP Address — To use this option, type the IP address of an intercom-equipped MLC 226 IP and IPI 201/204 series intercoms into the blank area to the right of this selection, then click the Add button. Repeat that process for ...
Page 54 - Rename
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-22 To change the MLC/ intercom’s name as it appears in the IP Intercom Management software , right-click on that MLC/intercom’s name, select Rename , then type in the new name. You must click the Update In...
Page 55 - Recording an original message
IPI 100 Series, IPI 200 Series • Configuration and Control 4-23 the Microsoft Windows operating system) to make your own WAV files. You need a Windows-based PC with a compatible microphone or other audio input device installed. Follow the procedure below. Recording an original message 1. Click the S...
Page 56 - Changing the audio format of
IPI 100 Series, IPI 200 Series • Configuration and Control Configuration and Control, cont’d 4-24 8. Type in a name for the new file in the file name area, and select the WAV file type. 9. Click the Change button. The Sound Selection window appears. Recorded sounds are saved as waveform (.wav) files...
Page 59 - SIS; IPI-initiated Messages
IPI 100 Series, IPI 200 Series 5 Chapter Five IPI 201 and IPI 204 Series SIS ™ Programming and Control Host-to-IPI Communication IPI-initiated Messages Commands and Responses
Page 60 - IPI 100 Series, IPI 200 Series • SIS Programming and Control; Programming and Control; gateway’s IP address:
IPI 100 Series, IPI 200 Series • SIS Programming and Control IPI 201/204 SIS ™ Programming and Control 5-2 The Extron MediaLink IP Intercom modules can be remotely set up and controlled via a host computer or other device (such as a control system) attached to the LAN port, or the front panel Config...
Page 61 - Password information
IPI 100 Series, IPI 200 Series • SIS Programming and Control 5-3 (c)Copyright 200 7 , Extron Electronics, IPI 201 V1.00, 60-809-00 ] Mon Day, DD Mon YYYY HH:MM:SS(c)Copyright 2007, Extron Electronics, IPI 204, V1.00, 60-810-00 ] Mon Day, DD Mon YYYY HH:MM:SSVx.xx is the firmware version number. The ...
Page 62 - IPI 100 Series, IPI 200 Series • Programming and Control; Error response references; Commands and Reponses; Using the command/response tables; ASCII to HEX Conversion Table; ASCII to Hex conversion table
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-4 E17 – System timed out E22 – Busy E24 – Privilege violation E26 – Maximum number of connections has been exceeded E27 – Invalid event number E28 – Bad filename or file not found E30 – Hardware failure ...
Page 63 - characters; must; Telnet; With Telnet you can use either an “Escape” (
IPI 100 Series, IPI 200 Series • Programming and Control 5-5 using URL-encoded commands. The ASCII and URL commands listed in the tables starting on page 5-8 perform the same functions, but they are encoded differently to accommodate the requirements of each port (Telnet or browser).The ASCII to hex...
Page 64 - the pipe character. With the Web browser, you are required; Symbol definitions
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-6 the pipe character. With the Web browser, you are required to use a “W” command and the pipe character. In either method, {Data} = data that will be directed to a specified port and must be hex encoded...
Page 67 - Relay functions
IPI 100 Series, IPI 200 Series • Programming and Control 5-9 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Relay functions For ce r elay on 1*1O 1 %2A1 O Rly 1 *1 Turn r elay on. For ce r elay of f 1*0O 1 %2A0 O...
Page 68 - Status commands
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-10 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Status commands V iew all voltage and temperatur e status 11S 11S...
Page 73 - IP setup commands
IPI 100 Series, IPI 200 Series • Programming and Control 5-15 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description IP setup commands Set the unit name 24 E X1@ C N } W X1@ CN | Ipn• X1@ ] Change the IPI’s name to one o...
Page 74 - set; Read
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-16 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Set date/time 24 E X1# C T } W X1# CT | Ipt• X1# ] X1# = Local da...
Page 75 - on
IPI 100 Series, IPI 200 Series • Programming and Control 5-17 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Set daylight saving time 24 E X3$ C X } W X3$ CX | Ipx X3$ ] X3$ = Daylight saving time (DST) is a r eg...
Page 80 - Passwor
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-22 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Passwor d and security settings Set administrator passwor d 24 E ...
Page 82 - Remapping port designations
IPI 100 Series, IPI 200 Series • Programming and Control IPI 201/204 SIS ™ Programming, cont’d 5-24 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Remapping port designations For security r easons the network adm...
Page 83 - Dir
IPI 100 Series, IPI 200 Series • Programming and Control 5-25 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description Set the Dir ect Access port map 24 E {port#}MD } W{port#}MD | Pmd {port#} ] Reset the Dir ect Access po...
Page 89 - Event Contr
IPI 100 Series, IPI 200 Series • Programming and Control 5-31 Command ASCII (T elnet) (host to inter com) URL Encoded (W eb) (host to inter com) Response (inter com to host) Additional description List files fr om the curr ent dir ectory and its subdir ectories E LF } WLF | (See r esponses to E DF }...
Page 91 - Appendix A; and Accessories; Specifications
IPI 100 Series, IPI 200 Series A Appendix A Specifications, Part Numbers, and Accessories Specifications Included Parts Accessories
Page 92 - Specifications, Part Numbers, Accessories; • Specifications, Accessories; Audio input — IPI
Specifications, Part Numbers, Accessories IPI 100 Series, IPI 200 Series • Specifications, Accessories A-2 Specifications — IPI 101, IPI 104 Series Audio — IPI 101, IPI 104, and MLC 226 IP Speaker ........................................... 1.4” (35.6 mm), 1-way, indoorFrequency response Line level ...
Page 93 - General; cable; Specifications are subject to change without notice.
IPI 100 Series, IPI 200 Series • Specifications, Accessories A-3 General Power .............................................. Supplied by MLC 226 IPPower input requirements ........... +12 VDC, <100 mADistance between MLC 226 IP and IP 100’ (30.5 m), maximum Connection types ........................
Page 94 - Specifications — IPI 201 and IPI 204 Series; Audio
IPI 100 Series, IPI 200 Series • Specifications, Accessories Specifications, Part Numbers, Accessories, cont’d A-4 Specifications — IPI 201 and IPI 204 Series Audio Speaker ........................................... 1.4” (35.6 mm), 1-way, indoorFrequency response Line level output ............... 2...
Page 95 - Control — relay
IPI 100 Series, IPI 200 Series • Specifications, Accessories A-5 Program control ............................. Extron’s control/configuration program for Windows ® Extron’s Simple Instruction Set (SIS ™ ) Microsoft ® Internet Explorer, Telnet Control — relay Number/type ................................
Page 96 - Enclosure dimensions; Rear; Regulatory Compliance
IPI 100 Series, IPI 200 Series • Specifications, Accessories Specifications, Part Numbers, Accessories, cont’d A-6 Enclosure dimensions IPI 201, IPI 204 faceplate... 4.5" H x 4.6" W x 0.1" D (11.4 cm H x 11.7 cm W x 0.3 cm D) (fits some 2 gang boxes) IPI 201 AAP, IPI 204 AAP faceplate 2....
Page 97 - Included Parts (IPI 101 AAP and IPI 104 AAP); These items are included in each order for an IPI intercom; Included parts; Accessories; MediaLink Controllers, labels; Button labels
IPI 100 Series, IPI 200 Series • Specifications, Accessories A-7 Included Parts (IPI 101 AAP and IPI 104 AAP) These items are included in each order for an IPI intercom module: Included parts Replacement part number IPI 104 AAP (black, white) 70-502-02, -03 IPI 101 AAP (black, white) 70-501-01, -03 ...
Page 98 - Included Parts (IPI 201 and IPI 204 Series); Part number
IPI 100 Series, IPI 200 Series • Specifications, Accessories Specifications, Part Numbers, Accessories, cont’d A-8 Included Parts (IPI 201 and IPI 204 Series) These items are included in each order for an IPI intercom module: Included parts Replacement part number IPI 201 AAP (black, white) 60-809-1...
Page 99 - Extron’s Warranty
Extron’s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will,...