1
Power down
Power down all attached devices before proceeding.
FF 120T
Flat Field Speaker
68-1450-02
Rev. A
07 09
User’s Manual
Loosen the two screws (do not remove) on the top terminal
cover plate and remove the cover plate.
• If a 70 V/100 V line distribution amplifier is being used,
such as the Extron XPA 2001-70V or XPA 2001-100V, the
cover plate is no longer needed since the included CPX 120
transformer cover plate will be installed in its place.
• If the 70 V/100 V line distribution system is not being
installed, retain the cover plate and proceed to step
N
Installation of conduit and conduit adapters should
conform to all applicable building codes and local
ordinances.
1
4’
2’
12”
End Section
24” x 48” Ceiling Tile
24” x 24” Ceiling Tile
2’
2’
12”
Draw Lines
Cut Material
The transformer side of the CPX 120 cover plate has a
7-connector terminal block. Route the two wires from the
amplifier through the cover plate hole to the transformer side.
The black negative (-) wire attaches to the “COM” terminal,
and the red postitive (+) wire attaches to the desired terminal
tap.
See the
NOTES below.
Top Terminal
Cover
Seismic Anchor
Ring
Locking Ring
From Amp
To Second Speaker
Flexible Conduit
Adapter
Flexible
Conduit
or
or
Cable Clamp
Adapter (supplied)
N
Installation in a plenum-rated environment
requires a wire gauge of 12 AWG to 18 AWG.
Pull the speaker wires from the conduit if a conduit is used.
Strip 3/16" (5 mm) from the wire ends, keep the wire end
strands together by twisting them (do not tin the wires), and
secure the wires to the appropriate taps on the terminal
block’s captive screw connectors as indicated on the tap
label. Use a small flat blade screwdriver to tighten the
terminal block screws. See the note below for wiring
additional speakers.
N
Route the speaker wires from the second speaker
through the cover plate hole to the transformer
side and twist the black negative (-) wires together
and twist the red positive (+) wires together before
inserting them into the terminal block. Additional
speakers can be daisy chained this way.
N
Be sure to observe the 70 V or 100 V system
designation as indicated on the label.
N
Wiring two speakers in parallel requires that the
maximum wire gauge not exceed 16 AWG. In a
single speaker installation the wire gauge should
not exceed 12 AWG.
When using flexible conduit, insert the conduit into the cover
plate opening using an appropriate conduit adapter and
secure the conduit to the plate as shown in the following
illustration.
NC
1 W
2 W
4 W
8 W
16
W
COM
70
V
100
V
COM
NC
16
W
8 W
4 W
2 W
1 W
2
Suspended ceiling installation
Remove the ceiling tile where the FF 120T speaker will be
installed. Cut out a 12" section of the tile from either end
where the speaker will be installed, as shown below.
3
Remove the terminal cover plate
4
Routing cables through the
CPX 120 cover plate
The CPX 120 cover plates mount to the speakers with
the transformer side down. See the illustration below.
5
Connecting wires to the CPX 120
terminal block
NC
1 W
2 W
4 W
8 W
16 W
COM
70
V
100
V
COM
NC
16 W
8 W
4 W
2 W
1 W
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
FF 120T Flat Field Speaker User’s Manual 2 When using plenum speaker wire without a conduit, insert the wire through the cable clamp adapter (included) and secure the adapter to the cover plate. • If a seismic support line is being used, install the seismic anchor ring (included) between the conduit...
FF 120T Flat Field Speaker User’s Manual If seismic support lines are being used, connect a line through the seismic anchor ring on the top terminal cover plate and attach it to one of the center seismic bendout tabs (the center tab is preferred) located on either side the speaker as shown below. Us...
FF 120T Flat Field Speaker User’s Manual Specifications Audio/acoustic and electrical General Speaker type................................. 1-way full-range in-ceiling speaker Frequency range........................... 68 Hz to 18 kHz, -10 dB, half spacePower capacity.............................. 1...