Page 2 - FCC Class A Notice; Extron Safety and Regulatory Compliance; CLASS 1 LASER PRODUCT; Safety Instructions; Русский; (简体中文)
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equ...
Page 3 - Software Commands; CE; File; Specifications Availability; Copyright; Registered Trademarks; S3 Service Support Solutions; Trademarks; Contents; Introduction
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents v Software Commands Commands are written in the fonts shown here: ^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03] E Y! * Y1& * Y2) * Y2# * Y2! CE } NOTE: For commands and examples of computer or dev...
Page 4 - WARNING; Risk of serious physical injury; About this Guide; DMS
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 1 vi DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents Introduction WARNING : Risk of serious physical injury — The DMS fiber optic I/O boards output continuous invisible light, which may be harmful to the eyes; use with caution. • Do not look in...
Page 5 - About the DMS Matrix Switchers; FOXBOX Tx DVI; Extron; Modular DVI Matrix Switcher; Typical DMS 3600 Application; Configurability; MUST
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 2 3 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction About the DMS Matrix Switchers The DMS 1600, DMS 2000, DMS 3200, and DMS 3600 (see figure 1) are configurable matrix switchers that distribute DVI signals and DFX transmitter and receiver ...
Page 6 - Installation; Rear Panel; I/O Board Configuration Overview; Input 5; Location A; Location A; Arrangement of Inputs and Outputs on the I/O boards
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 5 4 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction Installation This section describes installation of the DMS matrix switchers, including connections and features. Topics that are covered include: • Rear Panel • Front Panel Rear Panel I/O...
Page 7 - Making Connections; DVI-I Input connectors; DVI-I Output connectors; Fiber optic input ports
6 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 7 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation ANAHEIM, CA RESET RS232/RS422 REMOTE LAN ACT LINK REDUNDANT PRIMARY PRIMARY POWER SUPPLY REDUNDANT POWER SUPPLY FAN ASSIMBLY FAN ASSIMBLY 100-240V 50-60Hz 2.5A MAX. 100-240V 50-60Hz 2.5A M...
Page 8 - Front Panel; Front Panel Features
8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 9 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation e Remote port — If desired, connect a control system or computer to the rear panel Remote RS-232/RS-422 port. RS-232 Function Pin Function 1 2 3 4 5 6 7 8 9 — Tx Rx — Gnd ———— Not usedTran...
Page 9 - Front Panel Operations; Creating a Tie; The button lights to indicate the selection.; The output buttons blink to indicate the potential ties.; To
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations 11 10 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation Front Panel Operations This section describes simple DMS matrix switcher operation from the front panel. Topics that are covered include: • Creating a Tie • Viewing Ties (and M...
Page 10 - Remote Control; Selected SIS Commands; Establishing a Network (Ethernet) Connection; Saving or Recalling a Preset; Save a preset; The Preset button blinks.; Save a; Recall a preset; Recall a; The Preset button lights.; Locking Out the Front Panel (Executive Mode); seconds
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 13 12 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations Remote Control This section describes using the remote control features of the DMS matrix switchers to control the devices. Topics that are covered include: • Selected SIS Co...
Page 11 - Installing the; DMS Series; Common SIS Command Symbols; Command; ead tie
14 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Number of connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and Telnet connections. When the connection limit is reached, the switche...
Page 12 - ol; Command and Response Table for SIS Commands
15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol Command and Response Table for SIS Commands Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description NOTES : • Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003% ...
Page 13 - Assign EDID data to an input
16 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol 17 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description EDID NOTE: In the commands below, the EDID data can come from either an active output or be set ...
Page 14 - Channel mute commands; NOTE; Spr
18 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol 19 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description Channel mute commands Channel mute X@ *1B Vmt X@ *1 ] Mute output X@ (no signal is output). Chan...
Page 15 - nnn; Additional Description; IP and serial port setup; Command and Response Table for IP-Specific SIS Commands
20 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr ol NOTE: X1! = Address nnn . nnn . nnn . nnn X1@ = DHCP 0 = off, 1 = on Command ASCII Command (host to unit) Response (unit to host) Additional Description IP and serial port setup Set IP address EX1! CI } Ipi X1!] Default: 192 . 168 . 254 . 2...
Page 16 - Installing and Starting the Control Program; item; DMS Series Matrix Switchers User Guide; Installing the Program; Software DVD Window
21 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Installing and Starting the Control Program Another way to operate the switcher is via the Windows ® -based Matrix Switchers Control Program. This program is contained on the Extron Software Products DVD (included with the switcher) or on th...
Page 17 - First-time Connection Considerations; LAN port connection; Configuring for Network Communication; USB port connection; Starting the Program; Comm Port selection Window
22 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 23 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. Follow the on-screen instructions. The installation program creates a C:\Program Files\Extron\Matrix_Switchers directory and an “Extron Electronics\Matrix Switchers” group folder....
Page 18 - IP Connection Window; Examine the; Accessing the HTML Pages
24 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 25 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. If you selected IP [LAN] in step 2, the IP Connection window appears. Figure 12. IP Connection Window a. Examine the Matrix IP Address field, which displays the last Matrix IP add...
Page 19 - Loading the Start-up Page; DMS Series Matrix Switchers; Downloaded Start-up Page
26 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 27 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 5. Execute a ping command by entering ping followed by a space and the new IP address at the command prompt. For example: ping 10 . 13 . 197 . 7 C:\>ping 10.13.197.7 Pinging 10.13...
Page 20 - Removing and Installing an I/O Board or Blank Panel; See; on page 5 to understand
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 29 28 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Maintenance and Modifications This section describes repairing and reconfiguring the DMS matrix switchers by replacing components. Topics that are covered include: • R...
Page 21 - Knurled Knobs; Remove and Install an I/O Board; , align the board with the left and right chassis; Remove and Install a Power Supply Module
30 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 31 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications ANAHEIM, CA RESET REMOTE RS-232/RS-422 LAN BI-LEVEL TRI-LEVE L ACT LINK 100-240V 50/60Hz 1.2A MAX. 100-240V 50/60Hz 1.2A MAX. REDUNDANT PRIMAR Y DISCONN...
Page 22 - Knurled; Remove and Install a Fan
32 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 33 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 3. Slide the power supply out of the chassis. 4. Orient the power supply module to be installed with the LED to the right. 5. Align the flanges on the p...
Page 24 - Extron Warranty
Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, a...
Page 25 - © 2013 Extron Electronics All rights reserved.
Extron USA Headquarters +800.633.9876 (Inside USA/Canada Only) Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 FAX E xtron India 1800.3070.3777 (Inside India ...