Page 2 - Safety Instructions • English; Instructions de sécurité • Français; Sicherheitsanweisungen • Deutsch; Instrucciones de seguridad • Español; Chinese Simplified; 注 意; Chinese Traditional; 注意; Japanese; Korean; Safety Instructions
Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. ATTENTION: This symbol, , when used on the product, is intended to ...
Page 3 - FCC Class A Notice; accessibility, and related topics, see the “; Extron Safety and Regulatory Compliance; ” on the Extron website.; Copyright; © 2013 Extron Electronics. All rights reserved.; Registered Trademarks; Trademarks
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equ...
Page 4 - Conventions Used in this Guide; Notifications; potential; Specifications Availability
Conventions Used in this Guide Notifications The following notifications are used in this guide: WARNING: A warning indicates a situation that has the potential to result in death or severe injury. ATTENTION: Attention indicates a situation that may damage or destroy the product or associated equipm...
Page 5 - Contents; Introduction; Installing the CS 120P in a Suspended; CS 26T and CS 120P User Guide • Contents
Contents Introduction ............................................................ 1 About this Guide ................................................. 1Overview ............................................................ 1Features ............................................................. 1Appl...
Page 7 - About this Guide; US and metric ceiling grids; CS 26T and CS 120P User Guide • Introduction
Introduction This section gives an overview of the Extron CS 1226T SpeedMount Ceiling Speaker System, consisting of the CS 26T speakers and CS 120P enclosure. It also provides a list of system features and an application diagram. Topics include: • About this Guide • Overview • Features • Application...
Page 8 - Selectable taps; — The rotary tap selector switch, located behind the grille, sets the; Magnetic grille; — Magnets spaced around the grille edge enable it to be easily; Application Example; L I S; Application Diagram of a CS 1226T Installation
• Selectable taps — The rotary tap selector switch, located behind the grille, sets the speaker to operate in either 8-ohm direct or 70 volt /100 volt operation with 16, 8, 4, 2, and 1 watt taps. • Magnetic grille — Magnets spaced around the grille edge enable it to be easily attached and to remain ...
Page 9 - Installation; Installation Considerations; Risk of severe bodily injury from falling or sharp equipment.; Installation Configurations; For hard ceiling installations,; CS 26T and CS 120P User Guide • Installation
Installation This section provides instructions for installing the CS 26T speakers and the CS 120P enclosure. Topics include: • Installation Considerations • Installation Configurations • Installing the CS 1226T — Single Installer • Installing the CS 120P in a Suspended Ceiling — Division of Labor •...
Page 10 - Installing the CS 1226T System — Single Installer; before; Grid Face Example; only
Installing the CS 1226T System — Single Installer If a single installer is installing the CS 1226T system, follow this procedure for the entire system: NOTE: The ceiling grid must be installed before the installation of the CS 1226T begins. • Verify if fiberglass ceiling tiles are being used (see st...
Page 12 - Route wires through the conduit.; Using speaker wires without a conduit:; Secure the cable clamp adapter (included) to the cover plate.; Routing the Cables Without a Conduit
8. Route the cables through the cover plate — NOTES: • The CS 120P is fully UL 2043 compliant only when it is used with a metal conduit or with plenum rated cables. • Installation of all conduits, conduit adapters, wiring, and electrical connections must conform to all applicable building codes and ...
Page 13 - strips; Attach Four Tape Strips to the Baffle and Port Ring Adapter
9. Wire the CS 120P — Route the wires through the H-shaped opening in the CS 120P. Be sure to leave sufficient slack. Figure 8. Route the Wires Through the H-shaped Opening 10. Replace the terminal cover plate — Reinstall the terminal cover plate onto the CS 120P and tighten the two screws that were...
Page 14 - Fig: Mounting the PRE; not
12. Place the CS 120P into the ceiling grid — Place the CS 120P over the tile grid so that the CS 120P is safely supported on the two short edges. Ensure that the hole in the tile is aligned with the hole in the CS 120P (see figure 10). Fig: Mounting the PRE NOTE: 2' x 2' (600 mm x 600 mm) grid moun...
Page 15 - Signal Test Points
16. Attach the speaker wires to the captive screw connector — ATTENTION: Do not tin the wires. Tinned wires do not remain tight in the captive screws and can break easily after several bends. Number of Wires per Connection Point Maximum Wire Gauge 1 12 AWG 2 16 AWG 4 18 AWG Attach the speaker wires ...
Page 16 - Wiring Multiple Speakers Using Loop-through:; Wiring Multiple Speakers Using Loop-through; troubleshooting in three ways:; Signal Test Points — Loop-through Configuration
• Wiring Multiple Speakers Using Loop-through: A loop-through electrical connection is made on the crossover board of the CS 26T. Connect the wires to the captive screw connectors of the speakers, as shown in figure 15. Be sure to tighten the screws. Speaker 1 Speaker 2 Wiring Multiple Speakers Usin...
Page 17 - Impedance Test Points; Impedance Test Points — Loop-through Configuration; into the four-pole receptacle on the speaker; Connecting the Wire from the CS 120P to the Speaker
• The impedance of the speakers downstream of the one being tested can be measured while the system is on by connecting to the outer (LOOP) terminals of the captive screw connector, as shown in figure 17. Impedance Test Points To next speaker(s) Red Wire (+) from Amplifier Black Wire (-) from Amplif...
Page 18 - using the provided zip; through the bottom of the hole in the ceiling tile that was cut in; Do not overtighten the screws.
18. Attach the speaker wire to the strain relief tie down point using the provided zip tie. Captive Screw Connector Strain Relief Tab (zip tie) Figure 19. Attaching the Speaker Wire to the Strain Relief Point 19. Mount the CS 26T (see figure 20). a. Insert the CS 26T through the bottom of the hole i...
Page 19 - Attach secondary support lines; — If required, attach all of the secondary support; Do not; allow any slack in the support cables.; Open Back; Attaching Secondary Support Lines; — Reinstall the adjacent tile that was removed in step 4.
20. Attach secondary support lines — If required, attach all of the secondary support lines as shown in figure 21. ATTENTION: Do not allow any slack in the support cables. NOTE: If the CS 26T will be installed in the CS 120P, do not attach secondary support cables to the speakers. Secondary Support ...
Page 20 - Set the rotary tap selector switch; — Use a small screwdriver to set the tap selector; do; Adjusting the Rotary Tap Selector; Position the outer perimeter of the grille into the groove of the; Installing the Speaker Grille
22. Set the rotary tap selector switch — Use a small screwdriver to set the tap selector switch to the appropriate setting. ATTENTION: When setting the taps for a distributed (high impedance) system, do not tap the system above the rated power of the amplifier. When connecting multiple speakers in 8...
Page 21 - Installing the CS 120P in a Suspended Ceiling — Division of Labor
Installing the CS 120P in a Suspended Ceiling — Division of Labor In a division of labor installation, low-voltage contractors install the CS 120P enclosure (construction rough-in phase). NOTE: The ceiling grid must be installed before the installation of the CS 1226T can begin. • Verify if fibergla...
Page 22 - emove the adjacent ceiling tile; Removing the Cover Plate
4. Cut a hole for the CS 26T speaker. Use the provided cutout template to outline the hole to be cut in the ceiling tile as described below. (If the ceiling tile will not be installed during this phase of the installation, skip to step 6 .) a. Remove the ceiling tile. b. To find the center of the ti...
Page 23 - Tighten the clamp screws.
7. Route the cables through the cover plate — NOTES: • The CS 120P is fully UL 2043 compliant only when it is used with a metal conduit or with plenum rated cables. • Installation of all conduits, conduit adapters, wiring, and electrical connections must conform to all applicable building codes and ...
Page 26 - Installing the CS 26T in a Suspended Ceiling — Division of Labor; Disconnect power; Route the speaker wires
Installing the CS 26T in a Suspended Ceiling — Division of Labor In a division of labor installation, an AV system contractor installs the CS 26T (final installation phase). Use the following procedure: NOTE: Observe all applicable building codes and local ordinances when installing the speaker. 1. ...
Page 27 - Connect the wires to the captive screw
5. Attach the speaker wires to the captive screw connector — ATTENTION: Do not tin the wires. Tinned wires do not remain tight in the captive screws and can break easily after several bends. Number of Wires per Connection Point Maximum Wire Gauge 1 12 AWG 2 16 AWG 4 18 AWG Attach the speaker wires t...
Page 31 - — Position the outer perimeter of the grille into the groove of the
9. Set the rotary tap selector switch — Use a small screwdriver to set the tap selector switch to the appropriate setting. ATTENTION: When setting the taps for a distributed (high impedance) system, do not tap the system above the rated power of the amplifier. When connecting multiple speakers in 8-...
Page 32 - Installing the CS 120P in a Hard Ceiling; Do not leave a gap between the CS 120P and the ceiling material.
Installing the CS 120P in a Hard Ceiling If you are installing the CS 1226T in a hard ceiling (having no ceiling tiles), with the ceiling structure in place, install the CS 120P: • It is the responsibility of the installer to identify a suitable mounting location and provide the mounting hardware. •...
Page 33 - Contact Information; Extron Warranty; USA; xtron
© 2013 Extron Electronics All rights reserved. www.extron.com Contact Information Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 (Inside Europe Only)+...