Extron CLK 100 - Manual
Extron CLK 100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
usa west
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FA X
usa east
+1.919.863.1794 / +800.633.9876
+1.919.863.1797 FA X
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FA X
Japan
+81.3.3511.7655
+81.3.3511.7656 FA X
europe
+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FA X
dubai
+971.4.2991800
+971.4.2991880 FA X
asia
+65.6383.4400 / +800.7339.8766
+65.6383.4664 FA X
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
usa west
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FA X
usa east
+1.919.863.1794 / +800.633.9876
+1.919.863.1797 FA X
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FA X
Japan
+81.3.3511.7655
+81.3.3511.7656 FA X
europe
+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FA X
dubai
+971.4.2991800
+971.4.2991880 FA X
asia
+65.6383.4400 / +800.7339.8766
+65.6383.4664 FA X
sPecIFIcaTIons
cLock and TherMoMeTer
Clock accuracy
. . . . . . . . . . . . . . . . . .
<±30 seconds per month
Temperature display range
. . . .
+16 to +122 °F (-9 to +50 °C)
Temperature accuracy
. . . . . . . . .
±3 °F (±2 °C)
Temperature sampling
interval
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 minute
Temperature sampling
duration
. . . . . . . . . . . . . . . . . . . . . . . . . . .
0.1 to 0.2 s
GeneraL
Power
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supplied by internal batteries
Batteries
Number / Signal type
. . . . . . . . . . . . .
1 AAA battery (1.2 to 1.7 V)
Operating life
. . . . . . . . . . . . . . . . . . . . . .
1 year
Standby current
. . . . . . . . . . . . . . . . .
20 µA
Temperature sampling
current
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 µA
Temperature / Humidity
. . . . . . . .
Storage: +14 to +140 °F (-10 to +60 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Rack mount
. . . . . . . . . . . . . . . . . . . . . .
Yes, with optional 1U rack shelf, part #60-190-01 or 60-604-01; or
VersaTools
®
rack shelf, part #60-190-20 or 60-604-20
Enclosure type
. . . . . . . . . . . . . . . . . . .
Metal
Enclosure dimensions
. . . . . . . . . .
1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide)
4.2 cm H x 11.0 cm W x 7.6 cm D
Product weight
. . . . . . . . . . . . . . . . . .
0.3 lbs (0.1 kg)
Shipping weight
. . . . . . . . . . . . . . . . .
1 lbs (1 kg)
Vibration
. . . . . . . . . . . . . . . . . . . . . . . . . .
ISTA 1A in carton (International Safe Transit Association)
Compliances
. . . . . . . . . . . . . . . . . . . . .
CE
MTBF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30,000 hours
Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . .
3 years parts and labor
NOTE: All nominal levels are at ±10%. Specifications are subject to change without notice.
l c d c l o c k S & t h e r M o M e t e r S
CLK 100
12/24 Hour LCD Clock with Thermometer
FeaTures
•
High contrast, easy-to-read LCD display with 0.8 inch (20 mm) character
readout
— The front panel display is easy to read from across the room, even under
dim lighting conditions.
•
12/24 hour time and date display
— Facilitates time/date logging for service calls and
other applications.
•
Built-in thermometer with °F/°C temperature display
— Continuous display
of ambient temperature, updated every 60 seconds. The thermometer is useful in
identifying potentially excessive room or equipment rack heat conditions.
•
Back panel sensor reads operating temperature inside equipment rack enclosure
•
Runs on a single AAA battery - included
•
Ideal for desktop or rack-mount applications
•
Rack-mountable 1U, quarter rack width metal enclosure
descrIPTIon
The Extron
CLK 100
is a versatile, battery-operated LCD clock with an integrated thermometer,
ideal for monitoring the ambient temperature within an equipment rack or room. The CLK 100
displays the date and time of day in either 12 hour or 24 hour format, and temperature in
degrees Fahrenheit or Centigrade. Part of the VersaTools
®
line of small, economical, integrator
friendly products, the CLK 100 is housed in a 1U, quarter rack width metal enclosure for easy
rack mounting with other VersaTools products, and is equally at home in desktop or shelf
top applications.
ModeL
VersIon descrIPTIon
ParT #
CLK 100
LCD Clock with Thermometer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60-791-01
693
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.