Before installation of the AVTrac connectivity box, the base track must already

be installed. For full information about AVTrac installation, consult the

AVTrac Installation Guide.

Install the connectivity box as follows:

1

. Remove the cover panel and end plates from the

connectivity box. One end has three mounting holes

in the base, the other has two. The end with three

holes faces toward the wall. Align the end with

two mounting holes with the end of the base

track.

2

. Mark where the holes in the bottom of the

connectivity box lie over the base track and,

using a 1/4" metal bit (not provided), drill at

least three holes through the track.

3

. Using the provided masonry bit, drill 5/32" diameter

by 1 1/2" deep pilot holes into the concrete through the

predrilled holes in the track.

4

. Reposition the connectivity box, in the correct orientation, over the

track (the end of the box with three holes must face back toward the wall). Using at least three of the provided

3/16" masonry screws, secure the box to the track and floor.

5. Populate the lid of the box with the required Architectural Adapter Plates and AC power modules. Run cabling

as necessary, and reattach the end plates and cover panel.

AVTrac

Connectivity Box Installation Guide

End Plate

End Plate

Cover

3 Mounting Holes

2 Mounting Holes

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517

FA X

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797

FA X

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050

FA X

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664

FA X

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656

FA X

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566

FA X

Extron

Middle East

+971.4.2991800

+971.4.2991880

FA X

68-1617-01

Rev B

11 08

AVTrac

Power Module Installation Guide

Before installation of the AVTrac Power Module, the AVTrac base track and

connectivity box must already be installed. For full information about AVTrac

installation, consult the AVTrac Installation Guide. Install the AC module as

follows:

Slots

Studs

US
AC Power
Module

Tabs

C

All electrical installation should be

performed by qualified personnel in

accordance with local and national

electrical codes.

W

Switch off all electrical power before connecting

the AC conduit to a junction box, and keep power

off until installation is complete.

1

. Install the power module at the end of the connectivity

box that is closest to the wall. Slide the side tabs into the slots on the side of

the connectivity box and mount the power module on the stud(s) in the floor of

the box (see the figure above right). Secure the module to the stud(s) by hand

tightening the provided 6/32" nut(s).

2

. Run the unattached end of the conduit and connect it to a convenient junction or

circuit box (see the figure at left). Extron recommends that the junction box be

directly wired to the main circuit.

C

The module does not have a fuse and is rated at 15 A, maximum, for US modules and

10 A, maximum, for international modules.

Conduit

Junction Box

Green
or Green/Yellow
(ground)

AC Conduit
or Cable

From AVTrac AC
Power Module

To Main Circuit

White or Blue
(neutral)

Black or Brown
(hot)