Page 2 - Table of Contents; IMPORTANT NOTES – PLEASE READ BEFORE CONTINUING
MO270-EU-EN v2.3 5/14 2 Table of Contents Introduction .............................................................................................................................................. 2 Features ............................................................................................
Page 3 - Features; Analyzer Front View
MO270-EU-EN v2.3 5/14 3 MENU 05-12-2012 03:32:48 68.2 20.9 54.2 10.0 80.0 1 2 2 6 3 457 Features 1. Detachable sensors transmit data up to 65ft (20m) to the analyzer’s display 2. Readings from up to eight (8) remote sensors can be viewed 3. Wireless sensor affixes to 4 ft. (1.2m) telescoping handle;...
Page 4 - Analyzer Side Views; Analyzer Components; IMPORTANT
MO270-EU-EN v2.3 5/14 4 Analyzer Side Views 1. Sensor release buttons 2. Ports reserved for future options 3. RJ-45 remote probe port 4. Sensor (transmitter) mini-USB charge-port 5. Mini-SD card slot 6. Analyzer (receiver) mini-USB charge-port Analyzer Components 1. Cap with built-in calibration che...
Page 5 - Display Icons
MO270-EU-EN v2.3 5/14 5 Display Icons ICON Name Function (black) Low Alarm set Audible Low Alarm is set and active (black) High Alarm set Audible High Alarm is set and active (black) Low Alarm set Visual-only Low Alarm is set and active (black) High Alarm set Visual-only High Alarm is set and active...
Page 6 - Initial Setup and Battery Charging; Getting Started
MO270-EU-EN v2.3 5/14 6 Initial Setup and Battery Charging Getting Started 1. Charge the Sensor and the Analyzer batteries if necessary (refer to the ‘Charging the Batteries’ section below). The battery icons on the upper right corner of the display provide battery status for the Analyzer and the Se...
Page 7 - Operation; Basic Operation for Pin Measurements; Basic Operation for Pinless Measurements
MO270-EU-EN v2.3 5/14 7 Operation Basic Operation for Pin Measurements % CAUTION : The electrode measurement pins are extremely sharp, use care when handling this instrument. Cover the pins with the protective cap when the instrument is not in use. Note: make sure both slide switches are in the ON p...
Page 10 - Measurement Screen Menus; ALARM; MEMORY
MO270-EU-EN v2.3 5/14 10 Measurement Screen Menus F1 - MENU Press the F1 MENU button from the main analyzer display to open the sub-menu list: WME/REL The WME/REL menu allows for selecting either pin measurements, displayed as a ‘wood moisture equivalent %’ (WME), or pin-less measurements displayed ...
Page 12 - Alarm Operation; Trend Analysis Display Feature
MO270-EU-EN v2.3 5/14 12 Alarm Operation The HIGH and LOW Alarm limits are user programmable as described in the OPERATION (SETTINGS) section. Note that the High Alarm limit cannot be set lower than the Low Alarm limit and the Low Alarm Limit cannot be set higher than the High Alarm limit. When ...
Page 13 - Memory Logging Mode; Store a reading
MO270-EU-EN v2.3 5/14 13 Memory Logging Mode The MO270 has internal memory and optional SD memory. When the SD memory is installed, the SD memory is in use. The SD memory card is inserted with the pins facing up. . Store a reading To store a reading into one of the ten memory locations (known as G...
Page 14 - Downloading stored memory data to your PC; Calibration Verification; Calibration Zero Check for Pinless Mode
MO270-EU-EN v2.3 5/14 14 Downloading stored memory data to your PC Turn OFF the MO270 meter Connect the USB cable to the Display Analyzer portion of the meter. Switch the Analyzer ON using the power button (hold it for 3 seconds) and the menu show directly below will appear. Using the arrow ...
Page 15 - FCC Compliance; Battery Replacement
MO270-EU-EN v2.3 5/14 15 FCC Compliance FCC-ID: IWK-EX3000 FCC-ID: IWK-MO270X This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including i...
Page 16 - Specifications; Copyright
MO270-EU-EN v2.3 5/14 16 Specifications Display Full color graphical display Measurement resolution 0.1 Measurement accuracy Pin mode: ± (5% rdg + 5 digits) Pinless mode is a relative reading only Measurement principle Electrical resistance (pins) Electromagnetic sensor (pinless) Measurement ranges ...
Page 17 - Appendix – Wood Groups
MO270-EU-EN v2.3 5/14 17 Appendix – Wood Groups GROUP 9 is for Building materials – Plywood, drywall, OCD, etc. Common names of timbers (BS888 & 589: 1973) with MO270 program group numbers Abura 4 Gurjun 1 Pine, American Long Leaf 3 Afara 1 Hemlock, Western 3 Pine, ...
Page 19 - Botanical names of timbers with MO270 program group numbers
MO270-EU-EN v2.3 5/14 19 Botanical names of timbers with MO270 program group numbers Abies alba 1 Eucalyptus acmenicides 3 Picea jezoensis (8 ‐ 18%mc) 8 Abies grandis 1 Eucalyptus crebra 2 Picea sitchensis 3 Abies procera 8 Eucalyptus diversicolor 1 Pi...