Extech 42582 - Manual

Extech 42582

Extech 42582 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – Description; Meter Front Panel
  • Page 3 – Operation; Setup; Enable
  • Page 4 – IR non-contact Measurements; ON; Sample Printout
  • Page 5 – Manual Datalogging Mode; Manual Datalogging basics; MANUAL DATALOG SCREEN 1
  • Page 6 – HEADER EDITING; BACK; abcABC
  • Page 7 – Automatic Datalogging Mode; Log Screen 1; LOG SCREEN 1; AUTO DATALOGGER SETUP 1; AUTO DATALOGGER SETUP 2
  • Page 9 – Diameter of Spot
  • Page 10 – Specifications; General Specifications
  • Page 11 – Maintenance; Cleaning
  • Page 12 – Emissivity Considerations; Emissivity Factors for Common Materials
  • Page 13 – Software; System Requirements; Hardware Connection
  • Page 14 – Product specifications subject to change without notice; Warranty; Extech offers repair and calibration services; Copyright
Loading the manual

User's Guide




IR Thermometer
Printer / Datalogger

with External Contact Probe


Model 42582


















Introduction

Congratulations on your purchase of the Extech 42580 IR Thermometer Printer-Datalogger.
This device measures temperature with the non-contact IR sensor and the external contact
probe. The built-in Datalogger feature stores up to 12,000 readings. The readings can be
displayed directly on the meter or can be for transferred to a PC. The Printer provides a hard
copy of stored readings. Careful use of this meter will provide years of reliable service.

Safety

Use caution when the laser pointer beam is on

Do not point the beam toward anyone's eye or allow the

beam to strike the eye from a reflective surface

Do not use the laser near explosive gases or in other

potentially explosive areas

Line

Feed

F1

F2

F3

F4

ON/OFF

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Description; Meter Front Panel

Model 42582 Version 6.0 Sept 2007 2 Description Meter Front Panel 1. Laser pointer beam 2. Non-contact temperature sensor 3. LCD Display 4. Function Softkeys 5. Keypad 6. External Contact Probe 7. Probe Handle 8. Paper compartment 9. Printer paper Meter Side View 1. Printer 2. Keypad 3. LCD Display ...

Page 3 - Operation; Setup; Enable

Model 42582 Version 6.0 Sept 2007 3 Operation Press the ON/OFF button to power the meter. The WELCOME screen will appear along with four softkey selections (F1 through F4): Setup Two setup screens provide access to the Emissivity, LCD Contrast, Printer Contrast, Temperature Units, Laser Pointer ON/O...

Page 4 - IR non-contact Measurements; ON; Sample Printout

Model 42582 Version 6.0 Sept 2007 4 IR non-contact Measurements 1. Turn the instrument ON. 2. Press the F1 MEAS softkey from the WELCOME screen to enter the measurement mode 3. Point the meter at the surface to be measured. 4. Press and hold the ON button to take a reading while pointing toward the ...