Everpure MC - Manual

Everpure MC

Everpure MC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Some municipal plumbing codes; after the system. Systems certified for cyst reduction may; fluSHing; not for residential use. for food service applications only.
  • Page 3 – cArtriDge cHAnge proceDure; preSSure gAugeS; cArtriDge cHAnge DeterMinAtion
  • Page 4 – Toekomstlaan 30 • B-2200 Herentals, Belguim; technical Service; liMiteD WArrAnty; coMMerciAl WAter treAtMent equipMent; and is administered as follows:; for a period of one yeAr; replAceMent pArtS; Description; Inlet/outlet pressure gauge
Loading the manual

Selecting A Mounting locAtion

1. Give consideration to the weight of the unit when operating (filled with water). Operating weights

of High Flow CSR Systems are:

• Twin System - 45 lbs (20.2 kg)
• Triple System - 47 lbs (21.2 kg)
• Quad System - 49 lbs (22.2 kg)
• Quad Plus System - 49 lbs (21.2 kg) + separate surge/storage tank @ 60 lbs (27.2 kg)
2. The location should allow for (See figures 1-8):
• Minimum clearance of 2

1

2

" under the cartridge(s) so it can be lowered for removal and

replacement.

• Adequate space for “in” and “out” water line connections. Be near a drain for flushing and near

a 110V outlet if the optional Everguard

Low Pressure Alarm is used.

• Additional mounting and floor space for the separate SR-X Feeder and surge/storage tank

(Quad

Plus).

operAting SpecificAtionS*

combined Model name

replacement

cartridge

flow rate

capacity

High Flow CSR Twin - MC

MC

3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)

High Flow CSR Twin - MC

2

MC

2

3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)

High Flow CSR Twin - XC

XC

3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)

High Flow CSR Twin - XC

2

XC

2

3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)

High Flow CSR Twin - 4CB5

4CB5

3.3 gpm (12.5 lpm) 12,000 gal.(45,400 L)

High Flow CSR Twin - 7CB5

7CB5

5.0 gpm (18.9 lpm) 20,000 gal.(75,700 L)

High Flow CSR Triple - MC

MC

5.0 gpm (18.9 lpm) 27,000 gal.(102,000 L)

High Flow CSR Triple - MC

2

MC

2

5.0 gpm (18.9 lpm) 27,000 gal.(102,000 L)

High Flow CSR Triple - XC

XC

5.0 gpm (18.9 lpm) 36,000 gal.(136,000 L)

High Flow CSR Triple - XC

2

XC

2

5.0 gpm (18.9 lpm) 36,000 gal.(136,000 L)

High Flow CSR Triple - 4CB5

4CB5

5.0 gpm (18.9 lpm) 18,000 gal.(68,000 L)

High Flow CSR Triple - 7CB5

7CB5

7.5 gpm (28.5 lpm) 30,000 gal.(113,550 L)

High Flow CSR Quad - MC

MC

6.6 gpm (25.2 lpm) 36,000 gal.(136,000 L)

High Flow CSR Quad - MC

2

MC

2

6.6 gpm (25.2 lpm) 36,000 gal.(136,000 L)

High Flow CSR Quad Plus - XC

XC

6.6 gpm (25.2 lpm) 48,000 gal.(181,600 L)

High Flow CSR Quad Plus - XC

2

XC

2

6.6 gpm (25.2 lpm) 48,000 gal.(181,600 L)

* For individual cartridge specifications, refer to cartridge literature.

temperature:

35-100°F (2-38°C)

pressure:

10 - 125 psi (0.7 - 8.6 bar), non-shock

For cold water use only.

inStAllAtion

1. Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes.

Mount securely. See Figures 5-8.

2. Shut off power to equipment. If system is a High Flow CSR Quad Plus (separate SR-X Feeder and

surge/storage tank

), proceed to step 3b.

3a. Connect outlet ports of High Flow system to equipment served per the instructions below. Always

use NSF approved pipe dope or Teflon tape at all connections. Use a backup wrench on all fittings

while connecting to avoid stress on the system components.

• The cross fitting before the SR-X Feeder has a threaded outlet on top. Connect a minimum 1/2"

I.D. line from this outlet to fountain beverage equipment.

• The cross fitting has a flushing valve installed on the bottom. Connect tubing to the flushing valve

and run to drain. Note: Some municipal plumbing codes and good sanitary practices require an

air gap at the drain termination point.

Figure 1 – Twin

EV3112-78 Rev E AP08

Installation and Operation Guide

High Flow CSR Filter Systems

Figure 2 – Triple

Figure 4 – Quad Plus

Figure 3 – Quad

Manufactured by Everpure

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Some municipal plumbing codes; after the system. Systems certified for cyst reduction may; fluSHing; not for residential use. for food service applications only.

• Connect the outlet of the SR-X Feeder to the ice machine make-up water (not condenser water) line and coffee brewing equipment. Proceed to step 4. 3b. For High Flow CSR Quad Plus System, connect outlet to equipment served per the instructions be- low. Always use a NSF approved pipe dope or Teflon ...

Page 3 - cArtriDge cHAnge proceDure; preSSure gAugeS; cArtriDge cHAnge DeterMinAtion

cArtriDge cHAnge proceDure e-Series prefilter cartridge change 1. Shut off power to equipment. Shut off inlet water ahead of system. 2. Push red relief valve. Unscrew bowl. Remove prefilter cartridge. 3. Clean bowl with filtered water only; NO SPECIAL CLE ANERS. 4. Feel head o-ring. If dry, lubricat...

Page 4 - Toekomstlaan 30 • B-2200 Herentals, Belguim; technical Service; liMiteD WArrAnty; coMMerciAl WAter treAtMent equipMent; and is administered as follows:; for a period of one yeAr; replAceMent pArtS; Description; Inlet/outlet pressure gauge

for sales, replacement components, and service, contact your everpure dealer or:everpure, llc: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 800.323.7873 in europe: Toekomstlaan 30 • B-2200 Herentals, Belguim in Japan: Hashimoto MN Bldg. 7F • 3-25-1 Hashimoto Sagamihara-Shi • Kanagawa 229-11...

Other Everpure Models