- Page 2 – A letter from our Technical Support department:; IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER.
- Page 3 – If you see smoke coming out of your unit into the room; If you see smoke coming out of your unit into the room and; Remain calm
- Page 4 – IMPORTANT INFORMATION:; Read and comply with the instructions in this manual.; Your stove is designed to burn Premium Wood Pellets only.; Be sure your pellets are not damp or wet. Keep sawdust out of the unit.
- Page 5 – UNIT PREPARATION; Important– also check the; Test your 110-volt outlet for current and then plug in the unit. (; We highly recommend a surge; Visit our web site at
- Page 7 – FLUE SYSTEM; Be sure to check local codes in your area.; NOTE: See the installation drawing later in this manual (; Do not; Outside Air (Outside Combustion Air Intake); Outside air is mandatory for this unit to operate properly; Mobile Home Installation; This unit is not approved for mobile home use.; Important Notes Concerning Installation:; IMPROPER INSTALLATION:
- Page 8 – INSTALLATION INTO A MASONRY FIREPLACE; Always follow Local Codes!; working
- Page 9 – Illustration 1; FLOOR AND WALL PROTECTION; Floor Protection
- Page 10 – OPERATING INSTRUCTIONS; CAUTION: DO NOT OPERATE WITH THE DOOR OPEN.; Illustration 3; NOTE: Blower Speed should match or exceed Heat Range setting.
- Page 12 – DAILY OPERATION
- Page 13 – especially important; burn-back and can damage your unit and/or void your warranty.; ASH REMOVAL AND DISPOSAL; Daily Ash Maintenance; Twice each week: Shut the unit down by pressing; Illustration 6; remove any ash build-; Illustration 2
- Page 14 – Monthly Ash Removal; behind the burn pot (refer to the; this will require new gasket for the burn pot (Part #
- Page 15 – MAINTENANCE; CAUTION: UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK!; on the flat side of the gear shaft; Auger Bearings and Auger Shafts
- Page 16 – door gasket; Finish
- Page 17 – Control Board; not
- Page 18 – CAUTION: Moving Parts May Cause Injury.; Illustration 4 PU-CB04; Parts May Be Hot. Risk of Electric Shock.; IMPORTANT SAFETY NOTE:; Caution
- Page 19 – ACCESSORY ITEMS; Thermostats
- Page 20 – REPLACEMENT PARTS, ACCESSORIES AND OPTIONS; with
- Page 21 – Pellet Stove – Exploded View Diagram
- Page 22 – Cover Plate Assembly & Installation; Illustration 7
- Page 23 – TROUBLE-SHOOTING GUIDE; Problem
- Page 24 – The manufacturer extends the following warranties:; from the date of purchase.; Conditions and Exclusions:; Damage from over-firing will void your warranty.
- Page 25 – WARRANTY REGISTRATION for England’s Stove Works; DEALER INFORMATION; How did you first hear about our product? (please check one); IMPORTANT NOTICE; Technical Support Department; Visit
INSTALLATION & OPERATION MANUAL
MODEL NUMBERS:
25-PI
55-SHP20
55-TRP20
Thank you for purchasing this product from a fine line of heating equipment.
We wish you many years of safe heating pleasure with your new heating appliance.
Save These Instructions.
IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO
THE DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
Please Note the Following Precautionary Statements:
THIS PELLET INSERT IS NOT APPROVED FOR MOBILE HOME INSTALLATION.
FOR MASONRY FIREPLACE INSTALLATION ONLY!
NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT.
England’s Stove Works highly recommends the use of smoke detectors and Carbon
Monoxide detectors with any hearth product, including this unit. Follow all
manufacturer’s instructions when using smoke or Carbon Monoxide detectors.
CAUTION: Please read this entire manual before installation and use of this pellet
fuel burning room heater.
Keep children, furniture, fixtures, and all combustible materials away from
any heating appliance. Refer to this owner’s manual for all clearances to
combustible materials.
WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT
.
DO NOT OPERATE UNIT WITH HOPPER OPEN. LID MUST BE SHUT AND TIGHTLY SECURED.
DO NOT OPERATE WITH DOOR OPEN.
SAFETY NOTICE
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY
INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL THE
INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS FOR
RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS (INCLUDING PERMITS) IN
YOUR AREA.
Questions? Need Parts or Accessories?
IMPORTANT NOTICE: This unit must be properly installed to prevent the possibility of a
house fire or “smoke-back.” The instructions must be strictly adhered to.
Do not use makeshift methods or material which may compromise the installation.
Your unit requires periodic maintenance and cleaning (refer to manual). Failure to maintain
your unit may lead to a variety of problems, including but not limited to smoke spillage into the
home. England’s will not be liable for consequential or indirect damages to property or
persons resulting from the use of this product.
REV. 1/07
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your fav...
BEFORE RE-STARTING YOUR UNIT Every time before pressing “ON” to start your unit – Be sure to remove all ashes (burnt or partially burnt) from your burn pot area! Wearing protective gloves and with the unit cool, remove the Wear Plate and dump the ashes, ensuring that the air holes are clear from deb...
IMPORTANT INFORMATION: 1. Check local installation codes for your area. Call your Homeowner’s Insurance representative for inspection of your stove’s installation. 2. This unit is specifically designed to be installed in a masonry fireplace only. Use of this unit as a freestanding unit, or modificat...