Emerson Universal-R- User Manual
Emerson Universal-R– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Check the application limits before proceeding.; GENERAL DESCRIPTION
- Page 4 – Also take note of the number of probes to be connected.; probe to be fitted; STEP 3 - Turn on the power supply to the controller; When using 2 x probes, both must be the same type, you cannot mix them.
- Page 7 – Instructions Manual; READ ON IF YOU NEED MORE DETAIL; SERVICE REPLACEMENT - MODELS AND PROBE INFORMATION
- Page 9 – PARAMETERS – THEIR FUNCTIONS IN DETAIL; below
- Page 11 – BUTTONS – WHAT ARE THEIR FUNCTIONS; INDIVIDUAL BUTTON FUNCTIONS; PROGRAMMING MODE; EXIT TIME OUT - IMPORTANT
- Page 12 – OTHER FEATURES OF THE UNIVERSAL-R; LED’S; THERMOSTAT OVERRIDE ( not available when parameter “tC” = 1 or 6 )
- Page 13 – ALARMS; MUTING ALARM BUZZER & RELAY
Instructions Manual
cod. 1592001121
81,9(56$/²59
NEW FEATURES on the V3.0
•
HEATING :
As well as cooling, the Universal-R can now be used to control heating applications up to
+105c, using the NTC probes supplied in box.
For temperatures above 105c and up to maximum +150c, please order special PTC
probe (S6.SH), Part No. DIXL957
•
AUTOMATIC PROBE REGOGNITION:-
The Universal-R can work with either NTC or PTC probes.
It can now automatically recognise which type of probe is connected and set itself
accordingly.
During auto probe recognition, probe temperature must be Min. –50c, Max. + 60c
•
PROBES SUPPLIED AS STANDARD:
The Universal-R is now supplied with 2 of the latest fully encapsulated NTC probes
•
HOT KEY PROGRAMMING:-
You can now use a “Hot Key” (Part No. DIXL695) to transfer parameter settings between
one Universal-R and another (V3.0 only)
•
DIGITAL INPUT:
The Universal-R now has a digital input that you can configure to accept external signals,
i.e. - door switch, pressure switch, alarms, energy saving etc.
(9(1 025( )/(;,%,/,7< 025( &219(1,(1&( 7+(
81,9(56$/5
&$1 12: 5(3/$&( :(// 29(5 27+(5 &21752//(56
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instructions Manual cod. 1592001121 1592001121 Universal-R3 GB 19.11.2004.doc rel. 1.0 Pa. 3 / 15 2. GENERAL WARNING WARNING: The Universal-R should always be installed by a suitabley qua lified person, in accordance with bestelectrical and refrigeration practice. Take time to read the instructions....
Instructions Manual cod. 1592001121 1592001121 Universal-R3 GB 19.11.2004.doc rel. 1.0 Pa. 4 / 15 4. QUICK START UP PROCEDURE – Up and running in 6 easy steps This Quick Start Up section is designed to get you up and running with the minimum of fuss. Just follow these 6 simplesteps. STEP 1 - Using t...
Instructions Manual cod. 1592001120 1592001121 Universal-R3 GB 19.11.2004.doc rel. 1.0 Pa. 7 / 15 UNIVERSAL R Label Adjustment Range Factory defaults with parameter “tC” 1- 6 Thermostat probe calibration Ot - 12.0 ÷ 12.0 ° c 0.0 0.0 0.0 0.0 0.0 0.0 Evaporator probe calibration OE - 12.0 ÷ 12.0 ° c 0...