Page 3 - TABLE OF CONTENTS
i TABLE OF CONTENTS I MPORTANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . ....
Page 4 - ii; MultiLink
ii 3.4 Long Run Time (LRT) Battery Temperature Probe Terminals . . . . . . . . . . . . . . . . . . . . . . . 42 3.5 USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.6 MultiLink ® . . . . . . . . . . . . ...
Page 5 - iii; FIGURES
iii 7.2 Estimated Battery Run Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 7.2.1 Tables for UPS Model Number Where Digits 1-4 are S5KB . . . . . . . . . . . . . . . . . . . . . . . . . . 75 7.3 Estimated Battery Run Times . . . . . . . . ...
Page 6 - iv
iv Figure 37 Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Figure 38 Connection method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 7 - TABLES
v TABLES Table 1 Frame designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 2 Cable connection method reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 9 - SAVE THESE INSTRUCTIONS; Emerson representative immediately.; WARNING; gain access to the internal portions of the SolaHD S5KC.
Important Safety Instructions 1 SOLA HD ® S5KC ™ I MPORTANT S AFETY I NSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions. Read all safety, installation and operating instructions before operating the SolaHD S5KC modular UPS system. Adhere to all warnings on the un...
Page 10 - ELECTROMAGNETIC COMPATIBILITY; Information for the Protection of the Environment; UPS SERVICING; Products
Important Safety Instructions SOLA HD ® S5KC ™ 2 ELECTROMAGNETIC COMPATIBILITY —The SolaHD S5KC complies with the limits of Category C2, pursuant to IEC/EN/AS 62040-2, and for a Class A digital device, pursuant to Part 15 of FCC rules. Operation is subject to the following conditions: • The output c...
Page 11 - LOSSARY
Glossary of Symbols 3 SOLA HD ® S5KC ™ G LOSSARY OF S YMBOLS Risk of electrical shock Indicates caution followed by important instructions AC input AC output Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle DC voltage Equipment grounding...
Page 12 - RODUCT; components and specifications of the SolaHD S5KC UPS.; System Description; Figures 1; through; Table 1; UPS Model Number Digits 1-4
Product Introduction SOLA HD ® S5KC ™ 4 1.0 P RODUCT I NTRODUCTION Congratulations on your purchase of the SolaHD S5KC Uninterruptible Power System (UPS). As with every other SolaHD product, we stand behind our quality. If you have any questions concerning this UPS, please feel free to contact your ...
Page 13 - Figure 1
Product Introduction 5 SOLA HD ® S5KC ™ Figure 1 16-bay transformer-free UPS Figure 2 10-bay transformer-free UPS Manual Bypass Breaker (under the cover) Input Breaker (under the cover) User Interface Module Power, Battery or Charger Modules Battery Modules POD Ports RS-232 Port Dry Contacts Intelli...
Page 14 - Figure 3
Product Introduction SOLA HD ® S5KC ™ 6 Figure 3 12-bay transformer-based UPS Manual Bypass Breaker (under the cover) User Interface Module Power, Battery or Charger Modules Battery Modules POD Port RS-232 Port Dry Contacts Intelligent Card Slots Power Input and Output Terminals System Enabling Brea...
Page 15 - Figure 4
Product Introduction 7 SOLA HD ® S5KC ™ Figure 4 16-bay transformer-based UPS Manual Bypass Breaker (under the cover) User Interface Module Power, Battery or Charger Modules Battery Modules Front View - Bezels Removed POD Port RS-232 Port Dry Contacts Intelligent Card Slots Power Input and Output Te...
Page 16 - Features; SolaHD S5KC UPS; communication ports
Product Introduction SOLA HD ® S5KC ™ 8 1.2 Features SolaHD S5KC UPS • Flexible extension of capacity, up to 15 or 20kVA modular power, depending upon frame rating• N + 1 redundancy, improving availability• Module design, modules hot-swappable by user• Redundant intelligent module, providing redunda...
Page 17 - Operating Principle; The operating principle of the SolaHD S5KC UPS is shown in; Figure 5; Wiring
Product Introduction 9 SOLA HD ® S5KC ™ 1.3 Operating Principle The operating principle of the SolaHD S5KC UPS is shown in Figure 5 . Figure 5 Operating principle diagram The SolaHD S5KC UPS is composed of AC input, EMI filter, power module(s), battery module(s), user interface, control interface, s...
Page 18 - Operating Modes; Normal Mode; recharge time for long backup time applications.; Backup Mode; restoration of the AC utility/mains source.; Auto Restart Mode; inverter to the bypass source.
Product Introduction SOLA HD ® S5KC ™ 10 1.4 Operating Modes The SolaHD S5KC UPS is a true online double-conversion system, having the following operating modes: • Normal Mode• Backup Mode• Auto Restart Mode• Bypass Mode Normal Mode The power module rectifiers derive power from a utility AC source a...
Page 19 - Major Components; UPS Frame; The UPS frames are shown in; Figure 6; In
Product Introduction 11 SOLA HD ® S5KC ™ 1.5 Major Components This section provides a general description of each component and its functions. Please review this section carefully, as it will give you a better understanding of how the UPS operates. 1.5.1 UPS Frame The UPS frames are shown in Figure ...
Page 20 - User Interface Module; Figure 7; System Control Module and System Monitor Module; Figure 8; Handle
Product Introduction SOLA HD ® S5KC ™ 12 1.5.2 User Interface Module The user interface module is shown in Figure 7 . Figure 7 User interface module The user interface module is the primary source of communication between the UPS and the user. The user interface module permits: • Viewing the UPS sta...
Page 21 - Power Module; The power module is shown in; Figure 9; Battery Module; The battery module is shown in; Figure 10 Battery module appearance; be Off. For any other condition, refer to; NOTE
Product Introduction 13 SOLA HD ® S5KC ™ 1.5.4 Power Module The power module is shown in Figure 9 . Figure 9 SolaHD S5KC power module Each power module is an independent 5kVA unit, consisting of a power factor corrected rectifier, battery charger and inverter, with associated monitoring and control ...
Page 22 - Charger Module; shows the charger module.; Figure 11 Appearance of the charger module; connected battery system or connected equipment.; Figure 12 External battery cabinet; Green Status LED
Product Introduction SOLA HD ® S5KC ™ 14 1.5.6 Charger Module Figure 11 shows the charger module. Figure 11 Appearance of the charger module In AC mains mode, the charger module charges the system battery modules or external battery cabinet. Each charger module is rated to deliver 10A charging curre...
Page 23 - NSTALLATION; Unpacking Inspection; send a copy to your Emerson; Installation Environment; The tools required to properly set up your UPS are listed below:; Installation Site; Figure 13 Front and rear installation clearances
Installation 15 SOLA HD ® S5KC ™ 2.0 I NSTALLATION This chapter describes UPS installation, including installation preparation, unloading the UPS, mechanical installation, installing modules and cable connection. 2.1 Unpacking Inspection Upon receiving the UPS, uncrate it and conduct the following c...
Page 24 - Unloading the UPS; installation location.; Figure 14 Remove the mounting brackets; Sola S5KC
Installation SOLA HD ® S5KC ™ 16 2.2 Unloading the UPS The unit frame is bolted to the shipping pallet to ensure safety during shipping. Emerson recommends keeping the unit bolted to the pallet and using a pallet jack to transport the unit to its installation location. To unload the UPS:1. Move the ...
Page 25 - Mechanical Installation; Tower Installation; Figure 16 Adjust the leveling feet; mounting bolts removed from the pallet. Refer
Installation 17 SOLA HD ® S5KC ™ 2.3 Mechanical Installation Two installation modes are available for the SolaHD S5KC UPS: tower installation and rack installation. 2.3.1 Tower Installation 1. Once the UPS is in the desired location, adjust the leveling feet to secure its position, as shown in Figur...
Page 26 - Rack Installation; support the weight of the SolaHD S5KC.; Figure 18 Install cage nuts; bottom of the rack, as shown in; Figure 19 Install the tray; Detail A; Detail B
Installation SOLA HD ® S5KC ™ 18 2.3.2 Rack Installation 1. Install the cage nuts on the corresponding positions in the rack, as shown in Figure 18 . a. Install cage nuts in the two lower square holes of 1U space and in the two upper square holes of 2U space of all four rack posts. These cage nuts w...
Page 27 - Figure 20 Install the guide rails; Mounting Slot; Bracket
Installation 19 SOLA HD ® S5KC ™ Figure 20 Install the guide rails 4. Unscrew the 10 screws on the front of the two side panels of the UPS frame.5. Use those screws to attach the brackets to each side of the UPS frame, as shown in Figure 21 . Figure 21 Install the brackets C GuideRail Mounting Slot ...
Page 28 - Figure 22 Push the UPS frame into the rack
Installation SOLA HD ® S5KC ™ 20 6. Push the SolaHD S5KC frame slowly into the enclosure from the front, as shown in Figure 22 . The rear of the UPS goes into the rack first when installing through the front of the rack. Figure 22 Push the UPS frame into the rack 7. Use eight panel screws to secure ...
Page 29 - position on the lower front part of the UPS frame; Figure 24 Install the metal plate; The installation is complete, as shown in; Figure 25 Installation completed; Detail Area
Installation 21 SOLA HD ® S5KC ™ 8. Use four screws to install the metal plate (accessory in the rack-mount kit) on the corresponding position on the lower front part of the UPS frame 9. Insert the provided bezel into the square holes of the metal plate, as shown in Figures 24 and 25 . Figure 24 Ins...
Page 30 - Module Installation; the steps below to reinsert them properly.; Installing Power Module, Battery Module and Charger Module; Lift module to appropriate bay, resting end of module on bay shelf.
Installation SOLA HD ® S5KC ™ 22 2.4 Module Installation The SolaHD S5KC ships from the factory configured (modules prepopulated) and tested as a system to the customer’s requirements. If any modules were removed to facilitate ease of installation, follow the steps below to reinsert them properly. 2...
Page 31 - Figure 27 Lever and fastener; Locking Lever
Installation 23 SOLA HD ® S5KC ™ Figure 27 Lever and fastener 4. Replace the small bezels. NOTE If the lever of the module cannot be pressed down smoothly, remove the module and reinstall it. Locking Lever Fastener Pull Out Press Down Before Pressing Locking Lever (Side View) After Pressing Locking ...
Page 32 - Installing System Control and System Monitor Modules; NOTICE; remove power from the load. Replace these modules one at a time.; Figure 28 Remove large display bezel and user interface module; firmly to ensure that the module is fully inserted, as shown in; Figure 29 Insert the System Control and System Monitor module; Large Display Bezel
Installation SOLA HD ® S5KC ™ 24 2.4.2 Installing System Control and System Monitor Modules NOTICE Risk of unintended shutdown. Can cause equipment damage.Do not remove both the control and the monitor modules at the same time. Removing both the control module and monitor module at the same time wil...
Page 33 - Replace the LCD module and display bezel.; Cable Connection; Refer to the unit model number in; to determine which instructions to use for installation.; Table 2; Frame Type; Lever; Before Pressing
Installation 25 SOLA HD ® S5KC ™ 3. Use a #2 Phillips screwdriver to install the screws into the holes on each end.4. Slide the lever toward the right, as shown in Figure 30 . Figure 30 Lever and fastener on System Control and System Monitor Module 5. Replace the LCD module and display bezel. 2.5 Ca...
Page 34 - Transformer-Free UPS Cable Connection; Table 3; Table 4
Installation SOLA HD ® S5KC ™ 26 2.5.1 Transformer-Free UPS Cable Connection A junction box is factory-installed on each model of the SolaHD S5KC to ease cable connection.Select the appropriate input cables according to Table 3 and Table 4 based on the UPS rating and mains frequency; however, it is ...
Page 35 - panel of the UPS (see; Figure 32 Connection in single-phase input
Installation 27 SOLA HD ® S5KC ™ 2. Connect the cables to the corresponding terminal of the power input and output terminals.3. Tighten the screws to 4.52Nm (40 in-lb) with a 13mm (1/2") torque wrench.4. Respectively, secure the conduit of the input/output cables through the cable bridges on the...
Page 36 - Transformer-Based UPS Cable Connection; and; Table 7; based upon the UPS rating and; Table 5; recommends that the AC input supply be; Table 6
Installation SOLA HD ® S5KC ™ 28 2.5.2 Transformer-Based UPS Cable Connection A junction box is factory-installed on all models of the SolaHD S5KC to ease cable connection.Select the appropriate input cables according to Table 6 and Table 7 based upon the UPS rating and mains frequency. Emerson reco...
Page 37 - Configuring the Bypass Voltage; Table 9; for
Installation 29 SOLA HD ® S5KC ™ Configuring the Bypass Voltage The UPS bypass voltage is factory-set and the copper busbar jumper has been factory-installed. If the jumper setting does not match the input source, the bypass voltage jumper may need to be changed to ensure the correct output voltages...
Page 38 - Configuring the Neutral/Earth Jumper; Figure 36 Configuring the neutral/earth jumper; Connecting Cables; To connect the cable:; Figure 37 Knockouts; With Transformer
Installation SOLA HD ® S5KC ™ 30 Configuring the Neutral/Earth Jumper The UPS contains an isolation transformer that generates a neutral conductor for the connected load. The UPS is a separately derived source and contains a neutral/earth jumper. A factory-installed neutral/earth jumper copper bar m...
Page 39 - Refer to; in
Installation 31 SOLA HD ® S5KC ™ Figure 38 Connection method Refer to Table 7 for configuring the output cable. For standard voltages, make the connections shown in Table 9 . Table 10 shows the maximum load capacity of the output winding of the transformer-based UPS. Table 8 Key to Figure 38 UPS inp...
Page 40 - Transformer-Free UPS—Dual Inverter Frames; Figure 39 Knockouts
Installation SOLA HD ® S5KC ™ 32 2.5.3 Transformer-Free UPS—Dual Inverter Frames A junction box is factory-installed on all models of the SolaHD S5KC to ease cable connection.Select the appropriate input cables according to Tables 11 and 12 based on the UPS rating and mains frequency. Emerson recomm...
Page 41 - Figure 40 Secure cables on cable bridges; Figure 41 Wiring connections; Cable; OUTPUT
Installation 33 SOLA HD ® S5KC ™ 4. Respectively secure the input/output cables through the cable bridges on the rear panel of the UPS (see Figure 40 ). Figure 40 Secure cables on cable bridges The connections for the single-phase input mode and the 3-phase input mode are shown in Figure 32 and Figu...
Page 42 - Connecting External Battery Cabinet; EBC frame behind the bottom two bezels.
Installation SOLA HD ® S5KC ™ 34 2.5.4 Connecting External Battery Cabinet Up to four external battery cabinets may be connected to the SolaHD S5KC Series UPS to provide longer battery run times.The external battery cabinet (EBC) requires the use of one of the optional EBC cable kits for connection ...
Page 43 - external battery cabinets, as shown in
Installation 35 SOLA HD ® S5KC ™ Figure 42 Connecting external battery cabinet to a transformer-free UPS Figure 43 Connecting external battery cabinet (transformer-based UPS) After connecting the external battery cabinet, use the user interface to determine the number of external battery cabinets, a...
Page 44 - Figure 44 Battery screen; both have the locking levers in the locked position.; Connecting Integrated Power Output Distribution (POD); EBC DIP switch settings; DIP Switch Setting
Installation SOLA HD ® S5KC ™ 36 Figure 44 Battery screen If the number displayed is not consistent with the actual installation number of external battery cabinets: • Ensure each external battery cabinet contains two battery modules installed on the same row and both have the locking levers in the ...
Page 45 - Steps 1; Commissioning/Startup Procedures; This is the breaker located near the POD port.; should not be used if the UPS output voltage is set to 220/127V.; voltage and load ratings before energizing the load.
Installation 37 SOLA HD ® S5KC ™ equipment changes, while the UPS is still providing power. Follow these steps to properly and safely add or change the optional PODs.1. Ensure that the POD breaker is in the Off position. 2. Using a Phillips screwdriver, remove the two screws that are at the top of t...
Page 46 - POD breakers are closed.; power must be present to restart the UPS system.
Installation SOLA HD ® S5KC ™ 38 Commissioning/Startup with AC Power Available (Normal Mode Operation) ___ 1. Verify that the upstream mains AC breaker is closed.___ 2. Turn On the UPS Enable switch on the rear of the unit (it is protected by a clear plastic cover). ___ 3. Close the UPS input breake...
Page 47 - OMMUNICATION; IntelliSlot Ports; Figure 45 IntelliSlot communication port location; IntelliSlot
Communication 39 SOLA HD ® S5KC ™ 3.0 C OMMUNICATION The rear panel of the SolaHD S5KC provides these communication ports: • IntelliSlot ® ports: 3 • Dry contact ports: 1• REPO (Remote Emergency Power Off): 1• Long Run Time (LRT) Battery Temperature Probe Terminals: 1• USB port: 1 3.1 IntelliSlot Po...
Page 48 - communication to four servers for use with MultiLink software.; IntelliSlot EBC Card; external matching battery cabinets.; Dry Contact Ports; The UPS provides dry contact ports. See; for location and; Figure 46 Pin layout of the dry contacts; shows the pin definition of each dry contact port.; Battery Mode Dry Contact; Pin definition of dry contact port; Position
Communication SOLA HD ® S5KC ™ 40 IntelliSlot MultiPort Card (IS-MULTIPORT) Provides dry contact alarm information, including: On Battery, Low Battery signals for communication to four servers for use with MultiLink software. IntelliSlot EBC Card This card is used for the SolaHD S5KC UPS to monitor ...
Page 49 - Battery Mode Shut Down; Figure 47 REPO connector pin layout; REPO normally open nodes, shorting pins 9 and 10, REPO is triggered
Communication 41 SOLA HD ® S5KC ™ Battery Mode Shut Down Pins 7 and 8 : Input dry contact, normally open. After the external dry contact is closed (shorted), the UPS output will be shut down only during battery mode operation. 3.3 REPO (Remote Emergency Power Off) The SolaHD S5KC is equipped with a ...
Page 50 - cause signal noise, possibly causing the system to shut down.; Long Run Time (LRT) Battery Temperature Probe Terminals; temperature sensor. See; Figure 49 Pin layout of the temperature sensor terminal; USB Port; support or in conjunction with MultiLink
Communication SOLA HD ® S5KC ™ 42 NOTICE Risk of improper installation. Can cause unintended UPS shutdown and loss of power to the load.Run signal cables separately from power cables. Running cables in the same conduit can cause signal noise, possibly causing the system to shut down. 3.4 Long Run Ti...
Page 51 - be configured for use without the USB cable when the IntelliSlot; Figure 50 LCD port; LCD Port
Communication 43 SOLA HD ® S5KC ™ 3.6 MultiLink ® MultiLink monitors the UPS continuously and can shut down configured computers in the event of an extended power failure. MultiLink can also be configured to shut down the UPS. MultiLink can also be configured for use without the USB cable when the I...
Page 52 - PERATION; Overview; display panel, refer to; Figure 51 Operation and display panel; Mimic LEDs; LEDs are given in; LED descriptions
Operation and Display Panel SOLA HD ® S5KC ™ 44 4.0 O PERATION AND D ISPLAY P ANEL 4.1 Overview This chapter describes the functions and operation of the UPS display panel. The LCD is composed of an LED mimic power flow diagram, fault LED indicator and LCD screen to show detailed operational informa...
Page 53 - Audible Alarms; Figure 52 User interface module layout
Operation and Display Panel 45 SOLA HD ® S5KC ™ Audible Alarms Three different audible alarms may occur during the UPS operation; see Table 18 for a description of the audible alarms. Control Buttons The operation and display panel provides two control buttons. See Table 19 for their function descri...
Page 54 - LCD Screen; Startup Screen; which lasts for 15 seconds as shown in; Figure 53 Startup screen; Main Screen; and keyboard window, as shown in; Figure 54 Main screen; System Information Window; for the detailed description.; Item description of system information window; SolaHD S5KC; Industrial Automation
Operation and Display Panel SOLA HD ® S5KC ™ 46 4.2 LCD Screen 4.2.1 Startup Screen When the UPS starts up, it will conduct a self-test, and the LCD will display the startup screen, which lasts for 15 seconds as shown in Figure 53 . Figure 53 Startup screen 4.2.2 Main Screen The main screen is divid...
Page 55 - Menu Window and Data Window; for the menu and data descriptions.; Item description of menu window and data window; Menu Name
Operation and Display Panel 47 SOLA HD ® S5KC ™ Menu Window and Data Window The menu window shows the menu name and allows navigation to different menu items. Each menu item has a set of data that is displayed in the data window. Using the menu window, you can browse the relevant parameters of the U...
Page 58 - Keyboard Window; Function descriptions of menu buttons; Button
Operation and Display Panel SOLA HD ® S5KC ™ 50 Keyboard Window For the functions of the menu buttons (F1 ~ F5) in the keyboard window, see Table 23 Service Battery Maintenance Test Battery maintenance test allows battery to discharge some voltage to obtain the battery activity. The loads must be wi...
Page 59 - Default Screen/Screen Saver; Figure 55 Default screen/screen saver; LCD Screen Views; reference to the Output screen.; AC Mains Screen; Figure 56 Mains screen
Operation and Display Panel 51 SOLA HD ® S5KC ™ 4.2.3 Default Screen/Screen Saver During the UPS operating process, if there are no active alarms, the LCD will go into a screen saver mode after 2 minutes of no user navigation activity. The default screen saver is shown in Figure 55 . After a brief d...
Page 60 - Battery Screen; Figure 57 Battery screens; Output Screen; The main screen is the output screen by default, as shown in; Figure 58 Output screen; First Screen
Operation and Display Panel SOLA HD ® S5KC ™ 52 4.3.2 Battery Screen From the main screen, press the F3 button once and the battery screen will be displayed, as shown in Figure 57 . Figure 57 Battery screens On the first battery screen, pressing the F5 button will change the function of the F2, F3, ...
Page 61 - Load Screen; Figure 59 Load screen; level and crest factor.; UPS Information Screen; Figure 60 UPS info screen; battery module (if the modules are installed and are online).
Operation and Display Panel 53 SOLA HD ® S5KC ™ 4.3.4 Load Screen From the main screen, press the F4 button once and the load screen will be displayed, as shown in Figure 59 . Figure 59 Load screen The load screen displays output kVA (Sout/apparent power), output kW (Pout/active power), load level a...
Page 62 - Redundancy Screen; shown in; Figure 61 Redundancy screen; system contains a redundant module or not.
Operation and Display Panel SOLA HD ® S5KC ™ 54 4.3.6 Redundancy Screen From the main screen, press the F4 button three times until the redundancy screen is displayed, as shown in Figure 61 . Figure 61 Redundancy screen The redundant screen displays the number of installed power modules in the frame...
Page 63 - Settings Screen; Figure 62 Settings screens; primary functions to the secondary functions, as shown in; Entering a Password; the F3 button to enter the correct number.; SolaHD S 5KC Series; Fifth Screen
Operation and Display Panel 55 SOLA HD ® S5KC ™ 4.3.7 Settings Screen From the main screen, press the F4 button four times until the settings screen is displayed. The settings screen is displayed in a total of nine screens as you scroll down, as shown in Figure 62 . Figure 62 Settings screens On the...
Page 64 - Setting or Changing a Parameter Setting; Battery Setting Screen; Figure 63 Battery settings screen; Language Selection Screen; Figure 64 Language selection screen; The languages are displayed in their alphabet.
Operation and Display Panel SOLA HD ® S5KC ™ 56 4.5 Setting or Changing a Parameter Setting 1. Press the F4 button to navigate to the parameter to be set, and press the F5 button to enter the edit mode. 2. Press the F3 or F4 button to select the setting item or change the setting value, then press t...
Page 65 - Alarms Screen; Figure 65 Alarms screen; Records Screen; Figure 66 Records screen
Operation and Display Panel 57 SOLA HD ® S5KC ™ 4.5.3 Alarms Screen From the main screen, press the F4 button seven times until the alarms screen is displayed, as shown in Figure 65 . Figure 65 Alarms screen The alarms screen displays any current alarms of the UPS, including the alarm name, alarm ID...
Page 66 - displayed, as shown in; Figure 67 Module replacement screen; Prompt Window; a prompt window will pop up, as shown in; Figure 68 Example of prompt window; Module Replacement Screen
Operation and Display Panel SOLA HD ® S5KC ™ 58 4.5.5 Module Replacement Screen From the main screen, press the F4 button nine times until the module replacement screen is displayed, as shown in Figure 67 . Figure 67 Module replacement screen The module replacement screen displays the procedures for...
Page 67 - Information and actions required for the prompt window
Operation and Display Panel 59 SOLA HD ® S5KC ™ Table 24 Information and actions required for the prompt window Prompt Window Explanation Turn On/Off:Turn On UPSCancel When you press the ON/OFF-button while UPS is Off. Turn On/Off:Turn On INVTurn Off UPS When you press the ON/OFF-button while UPS is...
Page 68 - ROUBLESHOOTING; Active Alarms; possible alarm messages are displayed in; Alarm message list; Alarm Message
Troubleshooting SOLA HD ® S5KC ™ 60 5.0 T ROUBLESHOOTING This chapter provides the basic troubleshooting guide and required actions for maintaining the SolaHD S5KC system. 5.1 Active Alarms In the event of an alarm, the User Interface LCD will display the latest alarm message. A list of possible ala...
Page 71 - Module Troubleshooting; indicate the module operating state.; Figure 69 Module LED location
Troubleshooting 63 SOLA HD ® S5KC ™ 5.2 Module Troubleshooting The power, battery, charger, system control and system monitor module have two LEDs each to indicate the module operating state. Figure 69 shows the location of these LEDs; the meaning of the LED indicators is detailed in Table 26 . Figu...
Page 72 - Module Replacement; Removing Modules; power, battery or charger module
Troubleshooting SOLA HD ® S5KC ™ 64 5.3 Module Replacement Follow the instructions below when replacing or adding a system control, system monitor, power, battery, or charger module. Contact your local SolaHD representative if you need to purchase additional modules to expand your system or contact ...
Page 73 - Replacing the User Interface Module; to do so may cause unit to tip over and cause serious injury.
Troubleshooting 65 SOLA HD ® S5KC ™ Figure 71 Pull out a battery module, a power module or a charge module 5.3.2 Replacing the User Interface Module Replace the User Interface Module only while the SolaHD S5KC is turned On (System Enable switch On and input power available). If this module is replac...
Page 74 - Figure 72 Replacing the user interface module
Troubleshooting SOLA HD ® S5KC ™ 66 Figure 72 Replacing the user interface module
Page 75 - AINTENANCE; scheduled maintenance and procedures for cleaning fan filters.; Proper Care; your local SolaHD service representative for service.; Scheduled Maintenance; Top Filter; and clean the filters as described above.; Figure 73 Replace/clean the top filter; Mounting
Maintenance 67 SOLA HD ® S5KC ™ 6.0 M AINTENANCE This chapter describes the routine maintenance for the SolaHD S5KC UPS, including proper care, scheduled maintenance and procedures for cleaning fan filters. 6.1 Proper Care Proper maintenance of the UPS is imperative to optimal performance and life o...
Page 76 - Bezel Filter; Figure 74 Replace/clean the bezel filter; Bottom Fan Filter—Transformer-Based Frames Only; , and clean the filters as; Figure 75 Replace/clean the bottom fan filter; Bottom Fan Filters
Maintenance SOLA HD ® S5KC ™ 68 6.3.2 Bezel Filter 1. Remove the bezel from the frame.2. Remove the filter assembly from the bezel, as shown in Figure 74 , and clean the filters as described above. 3. Restore the filter and small bezel of the frame. Figure 74 Replace/clean the bezel filter 6.3.3 Bot...
Page 77 - PECIFICATIONS; SolaHD S5KC specifications
Specifications 69 SOLA HD ® S5KC ™ 7.0 S PECIFICATIONS Table 27 SolaHD S5KC specifications Unit Size, Type 10 Bay 16 Bay 12 Bay 16 Bay 10 Bay 16 Bay No Transformer Transformer-based No Transformer Dual Inverter Frame Rating, kVA/kW 15/13.5 20/18 15/13.5 20/18 15/13.5 20/18 General & Environmenta...
Page 78 - No Transformer
Specifications SOLA HD ® S5KC ™ 70 Battery Module Lead-Acid Batteries Per String 12 Battery Cells Per String 72 Battery Capacity 36W @ 15min-rate to 1.67V per cell @25 °C (77°F) Backup Time, Full Load 5 minutes (for non-redundant system which has equal number of battery strings and power modules) Ma...
Page 79 - SolaHD S5KC external battery cabinet specifications; Estimated Battery Run Times
Specifications 71 SOLA HD ® S5KC ™ Table 28 Rated input voltage range (Unit: VAC) System Configuration % UPS Load Low Limit Value High Limit Value Dual-Inverter Configured to 120 or 127 VAC per Phase >100% 98 ±3.1 139.5 ±3.1 90% ~ 100% 89 ±3.1 ~ 98 ±3.1 70% ~ 90% 74 ±3.1 ~ 89 ±3.1 30% ~ 70% 60.5 ...
Page 80 - Tables for UPS Where Model Number Digits 1-4 are S5KA
Specifications SOLA HD ® S5KC ™ 72 7.1 Estimated Battery Run Times 7.1.1 Tables for UPS Where Model Number Digits 1-4 are S5KA T a ble 30 10 -ba y , single- pha se , no t rans for mer uni t T y pe N (& UPS mode l nu mb er digit 9 = N) UPS Ra ti ng Loa d Lev e l # B atter y St ring s 1 23456789 1...
Page 83 - Tables for UPS Model Number Where Digits 1-4 are S5KB
Specifications 75 SOLA HD ® S5KC ™ 7.2 Estimated Battery Run Times 7.2.1 Tables for UPS Model Number Where Digits 1-4 are S5KB T a ble 3 3 1 6 -b ay , s ing le -ph ase , no t ran sf ormer un it T y p e N (& UPS mod e l n umber digit 9 = N) UPS Ra ti ng Lo ad Le ve l # Ba tt er y S tr in g s 1 2 ...
Page 86 - Tables for UPS model number digits 1-4 are S5KC
Specifications SOLA HD ® S5KC ™ 78 7.3 Estimated Battery Run Times 7.3.1 Tables for UPS model number digits 1-4 are S5KC T a ble 36 12 -b ay , single -ph ase , t rans fo rmer- bas e d unit T y pe N ( & UPS mode l nu mber 9 = N) UPS Ra ti ng Loa d Le ve l # B a ttery Stri ngs 1 2 3 4 5 6 7 8 9 10...
Page 89 - Tables for UPS Model Number Where Digits 1-4 are S5KD
Specifications 81 SOLA HD ® S5KC ™ 7.4 Estimated Battery Run Times 7.4.1 Tables for UPS Model Number Where Digits 1-4 are S5KD T a ble 39 16 -b ay , sing le -ph ase , t rans fo rmer- bas e d unit T y pe N ( & UPS mode l nu mber 9 = N) UPS Ra ti ng Loa d Le ve l # Ba tt e ry St rin g s 1 2 3 4 5 ...
Page 92 - Tables for UPS Model Number Where Digits 1-4 are S5KE
Specifications SOLA HD ® S5KC ™ 84 7.5 Estimated Battery Run Times 7.5.1 Tables for UPS Model Number Where Digits 1-4 are S5KE T a b le 4 2 1 0 -b ay , tw o- pha se , no t rans fo rmer unit T y pe N (& UPS mode l nu mber 9 = N) UPS Ra ti ng Loa d Le ve l # Ba tt e ry St rin g s 123456789 1 0 1 1...
Page 95 - Tables for UPS Model Number Where Digits 1-4 are S5KF
Specifications 87 SOLA HD ® S5KC ™ 7.6 Estimated Battery Run Times 7.6.1 Tables for UPS Model Number Where Digits 1-4 are S5KF T a ble 45 16- ba y , two-p h as e, n o t ra n sf ormer , un it T y p e N ( & UPS mod e l n u mber 9 = N) UPS Ra ti ng Loa d L e vel # Ba tt er y S tri n g s 123 45678 9...