Emerson Rosemount 3051CF - Manual

Emerson Rosemount 3051CF

Emerson Rosemount 3051CF – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
Page: / 34

Table of Contents:

  • Page 2 – Quick Start Guide; NOTICE; Explosions could result in death or serious injury.; Process leaks may cause harm or result in death.; Conduit/cable entries; Contents
  • Page 3 – System readiness; Confirm correct device driver; ) is loaded on your systems to; Rosemount 3051 device revisions and drivers; driver and documentation for your device.; fieldbus Device Revisions and Files
  • Page 4 – Figure 1. Installation Flowchart
  • Page 5 – Transmitter installation; Step 1: Mount the transmitter; Liquid applications; Gas applications; Coplanar; Steam applications; Coplanar
  • Page 6 – Figure 2. Panel and Pipe Mounting; Bolting considerations
  • Page 7 – Figure 3. Common Transmitter Assemblies
  • Page 8 – Table 2. Torque Values for the Flange and Flange Adapter Bolts; O-rings with flange adapters
  • Page 9 – Inline gage transmitter orientation; Figure 5. Inline Gage Low Side Pressure Port; A. Pressure Port Location; Note; “System readiness” on page 3
  • Page 10 – Figure 6. Commissioning Tag; Step 3: Housing rotation; Figure 7. Housing Rotation; Rotate the housing clockwise to the desired location.
  • Page 11 – Step 4: Set the switches; The security switch can be enabled or disabled in software.
  • Page 12 – on the terminal block label.; Figure 9. Wiring Terminals; Signal wiring grounding; Remove the Field Terminals housing cover.
  • Page 13 – Power supply; Locating devices
  • Page 14 – automatically returns to normal operation.; Each F; fieldbus host or configuration tool has a different way of; Configure the AI block; Figure 10. Configuration Flowchart
  • Page 15 – Figure 11. Basic Configuration Menu Tree; Before you begin; See; been enabled in software.
  • Page 16 – AI block configuration
  • Page 18 – Enable software write lock
  • Page 19 – AI block configuration parameters
  • Page 20 – DP Level example; Display pressure on the LCD display; Step 7: Zero trim the transmitter; Parameters
  • Page 21 – 051 Product Certifications; European Directive Information; North America; IE
  • Page 22 – Europe
  • Page 23 – International
  • Page 25 – Brazil
  • Page 26 – China
  • Page 28 – Japan
Loading the manual

Quick Start Guide

00825-0100-4774, Rev FA

June 2014

Note

Before installing the transmitter, confirm the correct device driver is loaded on the host
systems. See

“System readiness” on page 3

.

Rosemount

®

3051 Pressure Transmitter

Rosemount 3051CF Series Flowmeter
Transmitter

with F

OUNDATION™

fieldbus protocol

00825-0100-4774_RevFA.fm Page 1 Friday, June 6, 2014 2:21 PM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Quick Start Guide; NOTICE; Explosions could result in death or serious injury.; Process leaks may cause harm or result in death.; Conduit/cable entries; Contents

June 2014 2 Quick Start Guide NOTICE This installation guide provides basic guidelines for Rosemount 3051 transmitters. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-Proof, Flame-Proof, or intrinsically safe (I.S.) installations. Re...

Page 3 - System readiness; Confirm correct device driver; ) is loaded on your systems to; Rosemount 3051 device revisions and drivers; driver and documentation for your device.; fieldbus Device Revisions and Files

Quick Start Guide 3 June 2014 System readiness Confirm correct device driver  Verify the correct device driver (DD/DTM ™ ) is loaded on your systems to ensure proper communications.  Download the correct device driver at your host vendor download site, www.emersonprocess.com or www.fieldbus.org . ...

Page 4 - Figure 1. Installation Flowchart

June 2014 4 Quick Start Guide Figure 1. Installation Flowchart Start 1. Transmitter installation 2 . Commissioning tag 6 . Configuration Done Locate device 7 . Zero trim the transmitter 5. Grounding, wiring and power up 3 . Housing rotation 4. Set switches and software write lock 00825-0100-4774_Rev...