Model 499A CL-01

Free Chlorine Sensor

Instruction Sheet

PN 51A-499ACL01/rev.K
September 2010

SPECIFICATIONS - SENSOR

Pressure:

0 to 65 psig (0 to 549 kPa abs)

Temperature:

32 to 122°F (0 to 50°C)

Process Connection:

1 inch MNPT

Wetted Parts:

Noryl®

1

, Viton®

2

, platinum, polyethersulfone,

polyester, wood, silicone

Type

PN

Wetted Materials

Process Connection

Max.Temperature

Max. Pressure

1-1/2 in. tee

23567-00

CPVC, Buna N

1-1/2 in. socket

122°F (50°C)

65 psig (549 kPa abs)

915240-03

3/4 in. NFPT

2 in. tee

915240-04

PVC, Buna N

1 in. NFPT

120°F (49°C)

60 psig (515 kPa abs)

915240-05

1-1/2 in. NFPT

Low Flow*

24091-00

Polycarbonate/

Compression fitting for

158°F (70°C)

90 psig (722 kPa abs)

polyester, 316SS,

1/4 in. OD tubing

silicone

24091-01 (with

Polycarbonate/

Compression fitting for

158°F (70°C)

90 psig (722 kPa abs)

bubble sweep- polyester, 316SS,

1/4 in. OD tubing

ing nozzle)

silicone

1 Noryl is a registered trademark of General Electric.
2 Viton is a registered trademark of DuPont Performance Elastomers

SPECIFICATIONS - FLOW CELLS

For additional information, please visit our website

at

www.emersonprocess.com/raihome/liquid/

.

CAUTION

Do not exceed pressure and temperature specifications.
Pressure: 65 psig max (549 kPa abs max)
Temperature: 32 to 122°F (0 to 50°C)

CAUTION

SENSOR/PROCESS APPLICATION COMPATIBILITY
The wetted sensor materials may not be compatible
with process com

position and operating conditions.

Application compat ibility is entirely the responsibility of
the user.

* Pressure and temperature specifications for the low flow cell exceed the temperature and pressure specifications for the sensor.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Flow through; FIGURE 1. Sensor Orientation

2 MODEL 499A CL-01 INSTALLATION FIGURE 4. Low Flow Cell (PN 24091-00 or 24091-01) INSTALLATION Install the sensor in a flowing sample. Keep the sample flowas constant as possible at a value within the limits below. Flow through 1 to 5 gpm (3.8 to 19 L/min) Open channel 1 ft/sec (0.3 m/sec) Low flow ...

Page 3 - WIRING

MODEL 499A CL-01 WIRING WIRING 3 FIGURE 5. Wiring Sensor with Standard Cable toModel 1056 and Model 56 Analyzer FIGURE 6. Wiring Sensor with Optimum EMI/RFI orVariopol Cable to Model 1056 and Model 56 Analyzer FIGURE 7. Wiring Sensor with Standard Cable toModel 54eA Analyzer FIGURE 8. Wiring Sensor ...

Page 5 - CALIBRATION; Even in the absence of free chlorine, the; Use a wire nut and pigtail (included) when

FIGURE 13. Wiring Sensor with Standard Cable toModel 1066 Transmitter. FIGURE 14. Wiring Sensor with Optimum EMI/RFI orVariopol Cable to Model 1066 Transmitter. CALIBRATION Zero point: Even in the absence of free chlorine, the 499ACL-01 sensor generates a small signal called thezero current. Failing...

Other Emerson Models