Features
■
■
Three-stage■hybrid■protection
■
■
Sneak/fault■current■protection
■
■
Resettable■fuses■–■PTCs
■
■
Low■capacitance■option
■
■
Plug-in■module
■
■
Requires■Edco■PCB1B-WKEY■base
■
■
Fast■response■time
■
■
UL■listed■497B
■
■
5■year■warranty
Edco PC642 Series
Zone/Loop/Data
The■Edco■PC642■Series■surge■protective■device,■(SPD)■is■a■two-pair■(four■wire)■module■
implementing■ three-stage■ hybrid■ technology.■ This■ SPD■ addresses■ over-voltage■
transients■ with■ gas■ tubes■ and■ silicon■ avalanche■ components.■ In■ addition,■ sneak■
and■ fault■ currents■ are■ mitigated■ with■ resettable■ fuses■ (PTCs).■ The■ PTCs■ increase■
resistance■ several■ orders■ of■ magnitude■ when■ over-currents■ exceed■ safe■ levels.■ A■
normal■state■resumes■when■over-currents■are■removed.■The■ability■to■self-restore■in■
this■manner■significantly■increases■suppressor■performance■and■survivability.
The■Edco■PC642■card■edge■is■gold-plated,■double■sided■and■is■designed■to■mate■with■
the■ Edco■ PCB1B-WKEY■ gold-plated■ female■ terminal■ connector■ (sold■ separately).■
When■ snapped■ together,■ the■ data■ circuits■ “pass■ thru”■ the■ protector■ in■ a■ serial■
fashion■from■the■four■“Field■Side”■terminals■to■the■four■“Electronics■Side”■terminals.■
Terminals■1■or■10■of■the■PCB1B■must■be■attached■to■Building-Approved■Ground.
General Technical Specifications
Maximum■Operating■Voltage
5,■30,■36,■250■VDC
Clamping■Voltage
8,■36,■43,■300■VDC
Operating■Current
0.15■A
Peak■Surge■Current
10■kA■(8■x■20■μs)
Frequency■Range
0■to■20■MHz
Insertion■Loss
<■0.1■dB■at■50■MHz
SPD■Technology
GDT,■SAD,■w/■Series■PTC
Connection■Type
Terminal■Block,■w/■compression■lugs
Terminals■accept■up■to■10■AWG
Operating■Temperature
-40°C■to■+85°C
Dimensions■(in■/■mm)
2.0˝■H■x■1.0˝■W■x■2.5˝■L■(PC642■+■Base)
[50.8■x■25.4■x■63.5■mm]■
Weight■(oz■/■kg)
1■oz■[0.03■kg]
Certifications
UL■497A
EDCO PCB1B-WKEY BASE SOLD SEPARATELY
Seulement■le■personnel■qualifié■doit■installer■
ou■ maintenir■ ce■ systéme.■ Des■ précautions■
de■ sécurité■ en■ électricité■ doivent■ être■ suivis■
lors■ de■ l’installation■ ou■ de■ la■ maintenance■
de■ cet■ equipement.■ Pour■ eviter■ tout■ risque■
de■ choc■ électrique,■ débranchez■ et■ verouiller■
toutes■ les■ sources■ d’alimentation■ de■ cet■
equipement■avant■de.
Only■ qualified■ personnel■ should■ install■ or■
service■ this■ system.■ Electrical■ safety■ pre-
cautions■ must■ be■ followed■ when■ installing■
or■ servicing■ this■ equipment.■ To■ prevent■ risk■
of■ electrical■ shock,■ turn■ off■ and■ lock■ out■ all■
power■ sources■ to■ the■ unit■ before■ making■
electrical■connections■or■servicing.
V
DANGER!
■
Caution
Do not place this product in service on any signal line capable of supplying more than 150 mA continuously.
Attention
Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de
150 mA.