Emerson NetSure 4015 DC Power System- User Manual

Emerson NetSure 4015 DC Power System

Emerson NetSure 4015 DC Power System– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Home; “load distribution sub-racks”, which provide DC; Available Grounding Configurations; Complete Solution
  • Page 4 – TABLE OF CONTENTS; Factory System Integration
  • Page 6 – MAIN COMPONENTS ILLUSTRATIONS
  • Page 8 – Load Distribution Sub-Rack; HRMG Configuration
  • Page 10 – LIST DESCRIPTIONS
  • Page 11 – Power and Control Sub-Rack
  • Page 12 – Load Distribution Devices
  • Page 14 – Battery Tray
  • Page 15 – Temperature Probes; Up to two (2) temperature probes can be
  • Page 16 – Rack Integration (Factory Integrated System)
  • Page 17 – ACCESSORY DESCRIPTIONS; DIN-Rail Type Load Circuit Breakers
  • Page 18 – Table 1
  • Page 19 – User Replaceable Components; Ordering Notes
  • Page 20 – ONE LINE DIAGRAM
  • Page 21 – Equipment Grounding
  • Page 22 – grounding lead is factory connected between the; Recommended; None
  • Page 25 – DC Load Distribution (Bulk Output from Power and Control Sub-Rack)
  • Page 26 – SPECIFICATIONS; System DC Output Ratings; Derate to 50% of the output power from 260V to 304V AC.; System Environmental Ratings; Recommended with Batteries:
  • Page 28 – MECHANICAL SPECIFICATIONS
  • Page 29 – Dimensions and Weights; When Sold Separately:; When Factory Integrated:
  • Page 30 – Integrated System Shipping Weight
  • Page 31 – RELATED DOCUMENTATION; Power System Installation Instructions:; BATTERY MANUFACTURER INFORMATION; PowerSafe Enersys
Loading the manual

SAG584000300

System Application Guide

NetSure

4015 30kW 400V DC Power System

Spec. No. 584000300 (Model 4015-X003)

Issue AB, April 5, 2013

Page 1 of 32

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprie tary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly pro hibited.

Home

SYSTEM OVERVIEW

Description:

400V DC Output @ up to 30kW Power System

The NetSure

™ 4015, 30kW DC Power System is a complete integrated power system

containing rectifiers, intelligent control, metering, monitoring, and distribution. The
individual system sub-racks can be factory integrated into a standard

19” IT rack or

provided separately for customer integration into an existing IT rack.

This power system is capable of operating either with or without batteries online.

This system consists of the following components.

Power and Control Sub-Rack (List 11, 12)

The system contains one (1

) “power and control sub-rack”, which houses up to two

(2) rectifiers and the system control and monitoring components.

Rectifier(s)

The system contains one (1) or two (2) rectifiers, which provide load power,
battery float current, and battery recharge current during normal operating
conditions. Refer to the rectifier instructions (UM1R40015000e) for more
information.

Controls

ACU+ (Advanced Control Unit Plus) Controller

The system controller provides power system control, rectifier control (including a
charge control function), metering functions, monitoring functions, and
local/remote alarm functions. Power system control includes battery low voltage
disconnect (BLVD) functionality to remotely trip battery circuit breakers which
protects batteries against over-discharge. The system can also be equipped with
one (1) or two (2) temperature probe(s). Any combination of the two (2)
temperature probes can be programmed to monitor ambient air temperature
and/or battery temperature. A temperature probe set to monitor battery
temperature can also be used for the rectifier battery charge temperature
compensation feature and/or BTRM (battery thermal runaway management)
feature. The controller also provides data acquisition, system alarm
management, and advanced battery and energy management. The controller
contains an LCD display and keypad for local access. The controller provides
Ethernet connection and supports
software upgrade via its USB port. It also
comes with a comprehensive web page
and SNMP capability for remote system
management. Refer to the ACU+
controller instructions (UM1M820NNB-1)
for more information.

System Shutdown
A “System Shutdown” pushbutton is
located on the front of the power and
control sub-rack. When momentarily
depressed, the rectifier’s AC input circuit
breakers and the Emerson provided
battery trays’ battery disconnect circuit
breakers are tripped open to isolate the
system from all electrical sources.
Manual intervention is required to restart
the system.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Home; “load distribution sub-racks”, which provide DC; Available Grounding Configurations; Complete Solution

SAG584000300 System Application Guide Issue AB, April 5, 2013 NetSure ™ 4015 30kW 400V DC Power System Spec. No. 584000300 (Model 4015-X003) Page 2 of 32 This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprie tary information own...

Page 4 - TABLE OF CONTENTS; Factory System Integration

SAG584000300 System Application Guide Issue AB, April 5, 2013 NetSure ™ 4015 30kW 400V DC Power System Spec. No. 584000300 (Model 4015-X003) Page 4 of 32 This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprie tary information own...

Page 6 - MAIN COMPONENTS ILLUSTRATIONS

SAG584000300 System Application Guide Issue AB, April 5, 2013 NetSure ™ 4015 30kW 400V DC Power System Spec. No. 584000300 (Model 4015-X003) Page 6 of 32 This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprie tary information own...

Other Emerson Models