Emerson Liebert Deluxe System/3 DE- Installation Manual

Emerson Liebert Deluxe System/3 DE

Emerson Liebert Deluxe System/3 DE– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
Page: / 64

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; GLYCOOL; DISCONTINUED
  • Page 4 – ii; ATER
  • Page 5 – iii; FIGURES
  • Page 6 – iv; TABLES
  • Page 7 – Equipment Inspection; sales representative.; Table i; DH; WARNING; Hazardous voltage! Always disconnect power before servicing.; CAUTION; directly above any equipment that could sustain water damage.
  • Page 8 – Capacity and Cooling Type
  • Page 9 – Introduction; NTRODUCTION; System Descriptions; Two stages of mechanical refrigeration are available.
  • Page 11 – Installation; NSTALLATION; Room Preparation; of the total air circulated in the room.; Location Considerations; cleaning the humidifier.
  • Page 12 – Unit Dimensions; UNIT DIMENSIONAL DATA
  • Page 13 – Table 1; Air Cooled
  • Page 15 – Table 2
  • Page 17 – Table 3
  • Page 19 – Table 4
  • Page 20 – Piping; run parallel to the air flow.; Electrical Connections; the pump must comply with all applicable codes.
  • Page 21 – Figure 8 Electrical connection details; Remote Heat Rejection Connections; NOTES
  • Page 22 – Figure 9 Electrical field connections; Monitoring panel
  • Page 23 – Air Distribution Considerations; cable cutouts, cracks between the panels and other leakage areas.; Upflow Systems Additional Installation Considerations; Table 5; Direct
  • Page 24 – ing a duct to this flange may reduce airflow to inadequate levels.; Figure 10 Ducting configurations; Straight section of duct off of unit to be 1.5 to 2.5 times the
  • Page 25 – Figure 11 Plenum dimensional data for 6 - 22 ton models; Model
  • Page 26 – Figure 12 Plenum dimensional data for 30 ton models
  • Page 27 – Air Cooled Models; IR; Condenser Location; side. Proper grilles/screens are required on the outside wall.; local and national codes.
  • Page 28 – Refrigerant Piping; Table 8
  • Page 29 – Figure 13 Piping: Fan speed control condensers
  • Page 30 – Figure 14 Piping: Lee-Temp control condensers
  • Page 31 – Figure 15 Downflow air cooled (DH) piping connections
  • Page 32 – Figure 16 Upflow air cooled (VH) piping connections
  • Page 34 – Outdoor air cooled 1-4 fan condenser physical data
  • Page 35 – Outdoor air cooled 6 and 8 fan condenser physical data
  • Page 36 – Figure 19 Air cooled model general arrangement diagram; Fan Speed Control
  • Page 37 – air discharge opening.; Piggyback condenser dimensional data; FLOOR CUTOUT DIMENSIONS
  • Page 38 – Figure 21 Piggyback condenser piping connections; Piggyback condenser approximate refrigerant charges
  • Page 39 – Fan Speed Control Systems; monitoring refrigerant pressure.
  • Page 40 – Refrigerant control settings for air cooled units psi (kPa)
  • Page 41 – Lee-Temp/Flood Back Head Pressure Control Systems; damp cloth to keep the valve temperature below 250°F (121°C).
  • Page 42 – vapor through the suction port.; Figure 22 Lee-Temp control condenser; Top sight glass is 3/4 full; supplied and installed by others.
  • Page 43 – Figure 23 Lee-Temp control typical general arrangement diagram
  • Page 44 – Glycol Cooled/GLYCOOLTM Models; LYCOL; Drycooler Location; Proper grills/screens are required on the outside wall.; Drycooler Installation; the drycooler to steel supports or concrete pad.; supplied and mounted in the electric panel.; Glycol Piping; return lines should be insulated to prevent condensation.
  • Page 45 – Room dew point temperatures; Glycol concentration; Freezing Point; Refrigerant control settings for glycol cooled units—psi (kPa)
  • Page 46 – Figure 24 Downflow glycol cooled (DH) piping connections; Glycol Cooled Models; NA
  • Page 47 – Figure 25 Upflow glycol cooled (VH) piping connections
  • Page 48 – Figure 26 Downflow GLYCOOL; GLYCOOL Models; NOTE: Install all piping
  • Page 49 – Figure 27 Upflow GLYCOOL; UNIT CONNECTION LOCATIONS
  • Page 50 – Figure 28 1-4 fan drycooler cabinet and anchor dimensional data
  • Page 51 – -4 fan drycooler physical data
  • Page 53 – Preparation of Glycol Solutions; recommendations. Do not mix products of different manufacturers.; Automotive antifreeze is unacceptable and must NOT be used.; Galvanized pipe must not be used in glycol systems.
  • Page 54 – Figure 30 Glycol general arrangement
  • Page 55 – Figure 31 GLYCOOL
  • Page 56 – Water Cooled Models; Piping Considerations; installed near the base of the unit or below the elevated floor.; Condenser; capillary is not connected properly to the condenser.; Refrigerant control settings for water cooled units—psi (kPa)
  • Page 57 – Figure 32 Water cooled general arrangement
  • Page 58 – Figure 33 Downflow water cooled (DH) piping connections
  • Page 59 – Figure 34 Upflow water cooled (VH) piping connections; Optional Steam Humidifier; See Figure 37 for piping
  • Page 64 – Precision Cooling; IS
Loading the manual

Precision Cooling

For Business-Critical Continuity

Liebert Deluxe System/3

- DX

Installation Manual - 50 and 60 Hz, 6-30 Ton DX Systems (DH/DE/VH/VE)

DISCONTINUED

P R O D U C T

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; GLYCOOL; DISCONTINUED

i TABLE OF CONTENTS P RODUCT M ODEL I NFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V 1.0 I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 System De...

Page 4 - ii; ATER

ii 4.1 Drycooler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 4.1.1 Outdoor Prop Fan Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 4.1.2 Indoor Pig...

Page 5 - iii; FIGURES

iii FIGURES Figure 1 Downflow (DH and DE models) cabinet and floor planning dimensional data . . . . . . . . . . . . . . . . 4 Figure 2 Upflow 6, 8 and 10 ton (VH and VE models) cabinet and floor planning dimensional data . . . . . 6 Figure 3 Upflow 6, 8 and 10 ton (VH and VE models) blower duct and...

Other Emerson Models