Emerson HAS60E-IM-HW - Manual

Emerson HAS60E-IM-HW

Emerson HAS60E-IM-HW – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
Page: / 70

Table of Contents:

  • Page 2 – ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!
  • Page 3 – Instruction Manual; Table of Contents
  • Page 7 – PREFACE; WARNING
  • Page 8 – IMPORTANT; of all earth terminals must be maintained at all times.
  • Page 9 – OPERATING AND MAINTAINING THIS APPARATUS; NOTE
  • Page 10 – SAFETY SUMMARY; ELECTRICAL SHOCK HAZARD !
  • Page 13 – POWER SUPPLY; CAUTION; GASES AND GAS CONDITIONING (SAMPLE HANDLING); CAUTION
  • Page 14 – ELECTROSTATIC DISCHARGE; You prevent ESD by doing the following:; lectro
  • Page 15 – GENERAL PRECAUTIONS FOR HANDLING AND STORING; Compressed Gas Association; or placed in a cylinder stand, and is ready to be used.
  • Page 16 – DOCUMENTATION; Instruction Manual NGA 2000 CLD (this document); COMPLIANCES; NAMUR; SUITABILITY TESTS
  • Page 17 – GLOSSARY OF TERMS; The Operator Interface plus the Controller Board.
  • Page 18 – Primary Variable
  • Page 19 – ANALYZER SYSTEM ARCHITECTURE; Figure A-1: From separate analyzers to analyzer system
  • Page 20 – Network Cable
  • Page 22 – System unit; Control unit with front panel
  • Page 23 – SECTION 1; -2 TYPICAL APPLICATIONS
  • Page 24 – Table 1-1: Components depending on Module Configuration; Part Number; Back Pressure Regulator Brass 5 psig; Brief Description
  • Page 27 – General; Physical
  • Page 29 – SECTION 2; To install the CLD Analyzer Module into a Platform:
  • Page 30 – The gases must be; Air
  • Page 31 – Zero Gas; Ozonator Source Gas
  • Page 32 – Leak Test
  • Page 34 – Figure 2-5: Outline and Mounting Dimensions; INCHES
  • Page 35 – SECTION 3
  • Page 36 – Figure 3-2: Physical Measurements Display; Block Temperature; ppm NO
  • Page 39 – Figure 3-7: Calibration Parameters Display
  • Page 40 – Flow Balance Adjustment:; To adjust the Flow Balance Valve, select:; stays constant; If the measuring value; changes; after switching to
  • Page 42 – To adjust SIO functions, select; Analog Output Setup; Select the tag of the desired reference channel with the
  • Page 43 – Hold output during calibration:; Figure 3-15: Output Signal If Assigned Module
  • Page 45 – Serial interface Setup; The value can range from 1 to 50.
  • Page 46 – The list of modules will depend on the installed modules.
  • Page 47 – -6 CONVERTER TEMPERATURE ADJUSTMENT; Two conditions reduce the efficiency of the converter:
  • Page 50 – The presence on NO
  • Page 51 – Mode; A. TYPICAL TEST SETUP; BACKGROUND
  • Page 53 – SECTION 4
  • Page 54 – The main power fuse may require replacement.
  • Page 55 – Optional Bypass Flow Sensor
  • Page 59 – Te st Me dium
  • Page 60 – If there is a leakage, then proceed as follows:
  • Page 61 – SECTION 5
  • Page 63 – SECTION 6
  • Page 64 – -2 REPLACEMENT PARTS
  • Page 65 – SECTION 7; b. The environment in which the equipment was
  • Page 67 – LIST OF FIGURES AND TABLES; LIST OF FIGURES
  • Page 68 – LIST OF TABLES
Loading the manual

www.EmersonProcess.com

Instruction Manual

Chemiluminescence Detector
CLD Analyzer Module (combined with NGA 2000 Platform,
MLT, CAT 200 or TFID Analyzer)

1

st

Edition 06/2007

Instruction Manual

HAS60E-IM-HW
06/2007

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!

CLD Chemiluminescence Detector Instruction Manual HAS60E-IM-HW 06/2007 E m e r s o n P r o c e s s M a n a g e m e n tGmbH & Co. OHG Industriestrasse 1D-63594 HasselrothGermanyT +49 (0) 6055 884-0F +49 (0) 6055 884-209Internet: www.EmersonProcess.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE ...

Page 3 - Instruction Manual; Table of Contents

Instruction Manual HAS60E-IM-HWJune 2007 NGA 2000 CLD I Table of Contents Emerson Process Management GmbH & Co.OHG Table of Contents PREFACE ........................................................................................................................... P - 1 DEFINITIONS ................

Page 7 - PREFACE; WARNING

Instruction Manual HAS60E-IM-HWJune 2007 NGA 2000 CLD P - 1 Preface Emerson Process Management GmbH & Co.OHG PREFACE The purpose of this manual is to provide information concerning the components, functions, installation andmaintenance of the NGA 2000 CLD and the System Accessories of the NGA 20...

Other Emerson Models