Emerson Fisher i2P-100- User Manual
Emerson Fisher i2P-100– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Description; Specifications for the i2P‐100 transducer are listed in table 1.; WARNING; Educational Services
- Page 3 – Instruction Manual
- Page 4 – may
- Page 5 – Figure 2. Output‐Time Relationships for Fisher i2P‐100 Transducer; Installation
- Page 7 – No special conditions of safe use.
- Page 8 – Special Conditions of Use; ATEX; All Approvals
- Page 9 – Special Conditions for Safe Use
- Page 10 – Table 7. Hazardous Area Classifications—ATEX; Standards used for IECEx Certification
- Page 11 – Mounting; CAUTION; Pneumatic Connections
- Page 12 – Figure 5. Dimensions and Connections; Supply Pressure Requirements
- Page 13 – Diagnostic Connections; Figure 7. Diagnostics Hookup for Fisher i2P‐100 Transducer
- Page 14 – Vent; Electrical Connections
- Page 15 – the transducer grounding terminal to earth ground.; Figure 9. Equivalent Circuit; Operating Information; Calibration
- Page 16 – Refer to figure 10 for adjustment locations.
- Page 17 – for supply pressure recommendations.; Principle of Operation
- Page 18 – Figure 11. Fisher i2P‐100 Transducer Schematic; Maintenance
- Page 19 – Troubleshooting; Electrical
- Page 20 – Converter Module Replacement; Electronics Module Replacement; Removal
- Page 21 – Relay Maintenance; Refer to figures 12 and 14 for key number locations.
- Page 22 – Perform the procedure in the Calibration section of this manual.; Parts Ordering
- Page 23 – Figure 13. Fisher i2P‐100 Transducer Assembly; Parts Kits; Housing
- Page 25 – Mounting Parts; Yoke Mounting; Casing Mounting
- Page 26 – Loop Schematics/Nameplates; Figure 15. CSA Loop Schematic
- Page 27 – Figure 17. FM Loop Schematic
www.Fisher.com
Fisher
r
i2P-100 Electro‐Pneumatic Transducer
Contents
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Educational Services
. . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hazardous Area Classifications and Special
Instructions for “Safe Use” and Installation
in Hazardous Locations
. . . . . . . . . . . . . . . . . . . . .
CSA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATEX
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IECEx
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pneumatic Connections
. . . . . . . . . . . . . . . . . . . . .
Supply Pressure Requirements
. . . . . . . . . . . .
Diagnostic Connections
. . . . . . . . . . . . . . . . . .
Vent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections
. . . . . . . . . . . . . . . . . . . . . . .
Operating Information
. . . . . . . . . . . . . . . . . . . . . . . .
Calibration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Required
. . . . . . . . . . . . . . . . . . . . .
Calibration Procedure
. . . . . . . . . . . . . . . . . . . .
Principle of Operation
. . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Converter Module Replacement
. . . . . . . . . . . . . .
Electronics Module Replacement
. . . . . . . . . . . . . .
Relay Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. Fisher
i2P‐100 Electro‐Pneumatic
Transducer
W8710
REPLACEABLE
FILTER WITH
REMOVABLE
ORIFICE
INTEGRAL
PNEUMATIC
RELAY
VENT
Parts Ordering
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts List
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loop Schematics/Nameplates
. . . . . . . . . . . . . . . . .
CSA Loop Schematic
. . . . . . . . . . . . . . . . . . . . . . . .
CSA/FM Approvals Nameplate
. . . . . . . . . . . . . . . .
FM Loop Schematic
. . . . . . . . . . . . . . . . . . . . . . . . .
ATEX/IECEx Approvals Nameplate
. . . . . . . . . . . . .
Introduction
Scope of Manual
This instruction manual provides installation, operation, maintenance, and parts ordering information for the Fisher
i2P‐100 transducer (see figure 1).
Refer to separate manuals for instructions covering equipment used with the transducer.
Do not install, operate, or maintain an i2P
-
100 electro‐pneumatic transducer without being fully trained and qualified
in valve, actuator, and accessory installation, operation and maintenance.
To avoid personal injury or property
damage it is important to carefully read, understand, and follow all of the contents of this manual, including all safety
cautions and warnings.
If you have any questions about these instructions, contact your Emerson Process
Management sales office.
Instruction Manual
D103198X012
i2P-100 Transducer
July 2014
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instruction Manual D103198X012 i2P-100 Transducer July 2014 2 CAUTION Dropping or rough handling of the transducer can cause damage to the converter module resulting in a shifted output or aminimum output. Description The transducer receives a 4‐20 mA DC input signal and transmits a proportional use...
Instruction Manual D103198X012 i2P-100 Transducer July 2014 3 Table 1. Specifications Input Signal Available as standard with 4‐20 mA.User configurable by dip switch for split ranging, seetable below. Output Signal (1) Available as standard 0.2 to 1.0 bar (3 to 15 psig), 0.4to 2.0 bar (6 to 30 psig)...
Instruction Manual D103198X012 i2P-100 Transducer July 2014 4 Table 1. Specifications (continued) Electrical Housing: When Remotely Vented No Remote Venting CSA —Type 4X Encl. FM —NEMA 4X ATEX —IP66 IECEx —IP66 CSA —Type 3 Encl. FM —NEMA 3 ATEX —IP64 IECEx —IP64 Other Classifications/Certifications ...