  • Page 2 – pertinent information.; adequate sized hoists and chains or slings to handle the valve.; WARNING
  • Page 3 – Instruction Manual; Maintenance; performing any maintenance operations:; loosening the packing box pipe plug.; Installation; guidelines shown below.
  • Page 4 – leakage or breakage of the diaphragm has occurred.; Air Piping; to the 1/4 NPT in the lower diaphragm case. See figures 2 and 3.; Flow Direction; Use Flow From Port B to A; With fluids that have a tendency to cavitate.; Use Flow From Port A to B; Disassembly; relieve process pressure.
  • Page 5 – Lapping the Valve Seat; the bonnet with a wrench until there is metal-to-metal contact.; Calibration; CAUTION; Do Not Attempt to Rotate the Plunger (key 10)
  • Page 6 – to the actuator to calibrate the shut off position.; Parts Ordering; using the following parts tables.; Use only genuine Fisher
  • Page 7 – Figure 5. Seating Surfaces
  • Page 9 – Table 1. Common Parts
  • Page 11 – Figure 12. Baumann 16 Actuator with FIELDVUE; Figure 13. Baumann 16 Actuator with FIELDVUE; Table 4. Baumann Actuator Weights
Loading the manual

www.Fisher.com

Baumann™ 81000 Mikroseal Control Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Piping

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Flow Direction

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Lapping the Valve Seat

5

. . . . . . . . . . . . . . . . . . . . . . .

Bonnet Maintenance

5

. . . . . . . . . . . . . . . . . . . . . . . . .

Calibration

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions and Weights

10

. . . . . . . . . . . . . . . . . . . . . .

Figure 1. Baumann 81000 Control Valve

W9846

NPS 1/4 Angle Valve

with Baumann 16 Actuator

W9847

NPS 1/2 Inline Valve with

Baumann 16 Actuator, and

FIELDVUE

t

DVC2000 Digital

Valve Controller

Introduction

The Baumann 81000 Mikroseal control valve (figure 1) is excellent for throttling of liquid or gaseous media. A low

friction mechanical force-amplifying mechanism is used to reduce the travel of the pneumatic or electric actuators.

This mechanism moves the closure diaphragm precisely against the valve orifice to throttle or stop the passing fluid.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Baumann 81000 Mikroseal

control valve.

Do not install, operate, or maintain Baumann 81000 control valves without being fully trained and qualified in valve,

actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and

warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office

before proceeding.

Instruction Manual

D103366X012

81000 Valve

May 2012

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - pertinent information.; adequate sized hoists and chains or slings to handle the valve.; WARNING

Instruction Manual D103366X012 81000 Valve May 2012 2 WARNING Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal injury.Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may r...

Page 3 - Instruction Manual; Maintenance; performing any maintenance operations:; loosening the packing box pipe plug.; Installation; guidelines shown below.

Instruction Manual D103366X012 81000 Valve May 2012 3 Maintenance WARNING Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: D Do not remove the actuator from the valve while the valve is still pressur...

Page 4 - leakage or breakage of the diaphragm has occurred.; Air Piping; to the 1/4 NPT in the lower diaphragm case. See figures 2 and 3.; Flow Direction; Use Flow From Port B to A; With fluids that have a tendency to cavitate.; Use Flow From Port A to B; Disassembly; relieve process pressure.

Instruction Manual D103366X012 81000 Valve May 2012 4 4. A pressure gauge may be installed in the 1/8 inch port in the bolted bonnet (see figure 4). This gauge tells when leakage or breakage of the diaphragm has occurred. WARNING To avoid personal injury or property damage, do not attempt to do any ...