Table of Contents:

  • Page 2 – pertinent information.; adequate sized hoists and chains or slings to handle the valve.; WARNING; Maintenance; WARNING; performing any maintenance operations:
  • Page 3 – Instruction Manual; actuator cannot suddenly open or close the valve.; even when the valve has been removed from the; loosening the packing box pipe plug.; Installation; other foreign material.; CAUTION
  • Page 4 – Air Piping; to the 1/4 NPT in the lower diaphragm case.; Packing Adjustments; counterclockwise to loosen.; Disassembly; seals and plug out of the top opening of the valve body.; Reassembly and Calibration; Note; The flat side should rest in the bottom of the housing bore.
  • Page 5 – hanging up at the corner of the outlet port, see figure 5.; The force to pull up or push down the stem should not exceed 25 lbs.; yoke touches the shoulder of the bonnet.
  • Page 6 – instruction manual to determine what type of stops are being used).; Parts Ordering; using the following parts tables.; Use only genuine Fisher
  • Page 8 – Figure 2. Valve Body for Cv Rating of 2.5; It is highly recommended that the included PTFE
  • Page 11 – Figure 8. Dimensions for Baumann 32 Actuator with Options
Loading the manual

www.Fisher.com

Baumann™ 26000 Corrosion Resistant

Control Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Piping

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Packing Adjustments

4

. . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Reassembly and Calibration

4

. . . . . . . . . . . . . . . . . . .

Parts Ordering

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions and Weights

9

. . . . . . . . . . . . . . . . . . . . . . .

Figure 1. Baumann 26000 Control Valve

W9766

26000 Control Valve with

Baumann 32 Actuator

and Dual Travel Stops

26000 Valve with Baumann 32

Actuator, Dual Travel Stops, and

FIELDVUE

t

DVC6200 Digital

Valve Controller

X0423-1

Introduction

The Baumann 26000 Corrosion Resistant Control Valve (figure 1) features a flangeless wafer valve body. The 316

stainless steel flangeless body and thru-hole wafer design allows for installation between plastic pipeline flanges

without risk of gasket leakage. This same valve body, fully pressurized, retains an all wetted PTFE interior resulting in a

solid mechanical structure.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Baumann 26000 corrosion

resistant control valve.

Do not install, operate, or maintain Baumann 26000 control valves without being fully trained and qualified in valve,

actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and

warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office

before proceeding.

Instruction Manual

D103363X012

26000 Valve

May 2012

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - pertinent information.; adequate sized hoists and chains or slings to handle the valve.; WARNING; Maintenance; WARNING; performing any maintenance operations:

Instruction Manual D103363X012 26000 Valve May 2012 2 WARNING Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal injury.Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may r...

Page 3 - Instruction Manual; actuator cannot suddenly open or close the valve.; even when the valve has been removed from the; loosening the packing box pipe plug.; Installation; other foreign material.; CAUTION

Instruction Manual D103363X012 26000 Valve May 2012 3 D Do not remove the actuator from the valve while the valve is still pressurized. D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations. D Disconnect any operating lines providing air pressure, electric...

Page 4 - Air Piping; to the 1/4 NPT in the lower diaphragm case.; Packing Adjustments; counterclockwise to loosen.; Disassembly; seals and plug out of the top opening of the valve body.; Reassembly and Calibration; Note; The flat side should rest in the bottom of the housing bore.

Instruction Manual D103363X012 26000 Valve May 2012 4 Air Piping 1. For an air-to-extend actuator (air-to-close action), connect the actuating air pressure line to the 1/4 NPT opening in the upper diaphragm case. For an air-to-retract actuator (air-to-open action) connect the actuating air pressure ...