Table of Contents:
- Page 2 – Instruction Manual; Steel or Stainless Steel Valve:
- Page 3 – Installation; WARNING
- Page 4 – Table 3. Maximum and Minimum Allowable Mating Flange Diameters; actuator cannot suddenly open or close the valve.; loosening the packing box pipe plug.
- Page 5 – install a three-valve bypass around the control valve assembly.; CAUTION; inside diameter smaller than the minimum shown in table 3.
- Page 6 – are in full contact with the adjacent flanges.; Adjustments; Hub Seals; Key number locations are shown in figure 7.
- Page 7 – Figure 4. Grounding Assembly; To adjust the hub seals:; tightening the cap screws will cause the liner to fail.
- Page 8 – Linkage; been separated and the adjustment altered.; position if the two measurements are equal.; Three-Way Valve Tandem Linkage; necessary to ensure proper rotation of the slave valve disc.
- Page 9 – between the actuator and the power valve.; Maintenance; Disassembly; Key numbers locations are shown in figure 7.; the valve from the pipeline.
- Page 10 – Table 4. Troubleshooting Guide; the disc before removing the shaft.
- Page 11 – Table 5. Taper Pin Details for 9500 Series Valves; Reassembly; Parts List section to obtain replacement parts.; bonding agent from shaft holes and exposed liner surfaces.
- Page 12 – be reused. Use new taper pins whenever the disc has been removed.; shaft cannot be used with a new disc.
- Page 13 – Actuator Mounting; ) will rotate into the downstream side of the valve.
- Page 14 – Changing Disc Rotation and Action; travel stops and for instructions to change mounting style.; those shown in figure 6.
- Page 16 – Parts Ordering; Parts List
- Page 18 – Figure 7. Fisher 9500 Valve Body Assembly
www.Fisher.com
Fisher
r
9500 Butterfly Control Valve
Contents
Introduction
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustments
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hub Seals
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Linkage
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Three-Way Valve Tandem Linkage
8
. . . . . . . . . . . . . .
Maintenance
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disassembly
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reassembly
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuator Mounting
13
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing Disc Rotation and Action
14
. . . . . . . . . . . . .
Parts Ordering
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts List
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. Fisher 9500 Valve with 1052 Actuator and
DVC6200 Digital Valve Controller
W9224-2
Introduction
Scope of Manual
This manual provides installation, adjustment, and maintenance information for Fisher 9500 butterfly valves. These
valves use splined shafts with actuator-mounted brackets and linear-motion actuators (see figure 1). Refer to separate
manuals for instructions covering the power actuator or the manual handwheel actuator, positioner, and other
accessories.
Do not install, operate, or maintain 9500 valves without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to
carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you
have any questions about these instructions, contact your Emerson Process Management sales office before
proceeding.
Description
The 9500 valve is a fully lined butterfly valve for use with corrosive process fluids or wherever stringent shutoff is
required. The nitrile or PTFE liner completely isolates the valve body and shaft from the process fluid. The valve is
available with conventional or FISHTAIL™ disc designs.
Instruction Manual
D100380X012
9500 Valve
July 2012
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instruction Manual D100380X012 9500 Valve July 2012 2 Table 1. Specifications Valve Sizes NPS J 2, J 3, J 4, J 6, J 8, J 10, or J 12 Valve Body Style Flangeless (wafer-type) valve body to be installed between pipeline flanges End Connection Styles Flangeless (wafer-style) valve body mates with CL125...
Instruction Manual D100380X012 9500 Valve July 2012 3 Installation WARNING Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal injury.Personal injury or equipment damage caused by sudden release of pressure may result if the valve assemb...
Instruction Manual D100380X012 9500 Valve July 2012 4 Table 3. Maximum and Minimum Allowable Mating Flange Diameters VALVE SIZE, NPS MAXIMUM AND MINIMUM DIAMETER OF MATING PIPING OR FLANGES Minimum Maximum mm Inches mm Inches 234 306489 1.202.503.50 6492 117 2.503.624.62 68 1012 145196246297 5.707.7...