Emerson Fisher 8510- User Manual
Emerson Fisher 8510– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Instruction Manual; Table 1. Specifications; Applicable Valve Designs; See table 2; Applicable Shaft Diameters; Vee‐Ball and Eccentric Disc Valves:; Pressures and Temperatures; Maximum Application Temperature; Removing the Actuator; actuator cannot suddenly open or close the valve.; loosening the packing box pipe plug.; WARNING
- Page 3 – Figure 1. KALREZ Packing Arrangements
- Page 4 – Installing a KALREZ Packing System; CAUTION; Note; All kits include a single use packet of KRYTOX
- Page 5 – Other Considerations; then your packing should work fine.
- Page 6 – Table 2. Rotary KALREZ Applications and Packing Set Part Numbers
www.Fisher.com
KALREZ
r
Packing System
for Fisher
r
Rotary‐Shaft Valves
Contents
Introduction
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the Actuator
2
. . . . . . . . . . . . . . . . . . . . . . .
Installing a KALREZ Packing System
4
. . . . . . . . . . . . .
Tightening Procedures
5
. . . . . . . . . . . . . . . . . . .
Other Considerations
5
. . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for KALREZ valve stem packing
(KVSP) systems. These systems are available for Fisher rotary valves with 12.7 through 38.1 mm (1/2 through 1‐1/2
inch) shaft diameters. The system can be used with many rotary valves, as shown in table 1. Refer to appropriate valve
and actuator instruction manuals for necessary information relating to the disassembly and assembly of the valve and
actuator.
Do not install, operate, or maintain a KALREZ packing system without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is
important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and
warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office
before proceeding.
Description
See table 1 for valve designs and shaft diameters where KALREZ packing systems can be applied.
Emerson Process Management offers KALREZ packing systems that you can easily install into your existing valves or
that you can purchase with new valves. The KVSP 500 Series uses Vespel
r
CR‐6100 backup rings and KALREZ seal
rings.
The external live‐loading provides a constant load over the life of the packing material, which reduces the need for
packing box adjustment and maintenance.
Installation
Use these instructions to install KALREZ packing in valves that have standard packing, or when inspecting or replacing
KALREZ packing.
Table 2 lists part numbers for KALREZ packing sets only. When retrofitting valves to KALREZ packing, contact your
Emerson Process Management sales office for information on additional parts needed.
Instruction Manual
D102137X012
KALREZ System - Rotary-Shaft Valves
May 2011
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instruction Manual D102137X012 KALREZ System - Rotary-Shaft Valves May 2011 2 Table 1. Specifications Applicable Valve Designs A41, 8510, 8510B (single arrangements only), 8550,and 8560 valves; V100, V150, V200, V300 and V500Vee‐Ball t valves; and CV500 Cam‐Vee‐Ball valves. See table 2 Applicable Sh...
Instruction Manual D102137X012 KALREZ System - Rotary-Shaft Valves May 2011 3 Figure 1. KALREZ Packing Arrangements 44B7499-A 8510 OUTBOARD END V100 - 12.7, 19.1, 25.4, 31.8 (1/2, 3/4, 7/8, 1, 1‐1/4 ) SHAFT V150 - 12.7, 19.1, 25.4 (1/2, 3/4, 1 SHAFT V200 & V300 - 12.7, 15.9, 19.1, 25.4 (1/2, 5/8...
Instruction Manual D102137X012 KALREZ System - Rotary-Shaft Valves May 2011 4 Installing a KALREZ Packing System Refer to figure 1. Note When installing a KALREZ packing system into an insulated valve, do not cover the Belleville packing springs with insulation. CAUTION Use caution when removing exi...