Emerson DLC3020f- User Manual

Emerson DLC3020f

Emerson DLC3020f– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

D103602X012 May 2012

Field Communicator Menu Tree

www.Fisher.com

FIELDVUE™ DLC3020f Digital Level Controller

FIELDVUE and Fisher are

marks owned by one of the companies in the Emerson Process

Management business unit of Emerson Electric Co. Emerson, Emerson Process
Management, and the Emerson logo are trademarks and service marks of Emerson
Electric Co.

© 2012 Fisher Controls International LLC. All rights reserved.

Home
 Overview
 Configure
 Service Tools
  (on back side)
 Advanced

Process Fluids (Interface only)

 Upper Fluid

 Lower Fluid

Change Process Fluid

 Temperature Compensation

Density Tables

Calibration/Setup Log
  Methods

 View
 Restore
 Save Current
 Rename
 Delete

Device

 Variable Configuration
 Sensor Units
 Sensor Parameters
 Torque Tube
 Sensor Hardware Information

Configure

Instrument Setup

 Manual Setup

 Alert Setup
  (on back side)
 Calibrate
  (on back side)

Overview

 Check Status
 Primary Purpose Variables
 Shortcuts

Check Status

 Device Status:
   Good
   Failed
   Maintenance or
   Advisory
 Mode Status:
   In Service or
   Not in Service

Variable Configuration

 Type of Measurement
 Primary Value Range High
 Primary Value Range Low
 Primary Value Offset
 Primary Value Range Units

Calibration In Use

 Name
 Date
 Calibration Method
 Calibrator

Calibration/Setup Logs

 Calibration in Use
 Calibration/Setup Log Methods

Menu Tree applies to

Device Revision

DD Revision

Firmware Revision

1

1.0

0x03

Hardware Revision

1.0

475 Field

Communicator

Shortcuts

 Device Information
 Calibration/Setup Logs

Device Information

 Device Overview
 Version Information
 Manufacturing Information

Device Overview

 Instrument Model Number
 Instrument Serial Number

Version Information

 Device Revision
 Firmware Revision
 Hardware Revision
 Major Sensor Revision
 Minor Sensor Revision

DD Information

Manual Setup

Mode

 Device
 Process Fluid (Level only)
 Process Fluids (Interface only)

Instrument Display

 Snap Acting Control
 Options

 (continued on back side)

Sensor Hardware Information

 Model Type
 End Connection Style
 End Connection Type
 Body Material
 Pressure Rating
 Mechanical Sensor Serial Number
 Displacer Size
 Displacer Material
 Displacer Rating
 G Dimension
 Torque Tube Material
 Torque Tube Wall
 Heat Insulator 

Manufacturing Information

 Lever Assembly ID
 Communication Module ID
 Sensor Module ID
 Shop Order Number
 Terminal Box Date Code

Sensor Units

 Unit System
 Length Units
 Volume Units
 Weight Units
 Temperature Units
 Torque Rate Units
 Fluid Density Units

Sensor Parameters

 Displacer Length
 Displacer Volume
 Displacer Weight
 Driver Rod Length
 Instrument Mount Position

Torque Tube

 Torque Tube Material
 Compensated Torque Rate
 Torque Tube Table

Torque Tube Table

 Temperature 1
 Gain 1
 Temperature 2
 Gain 2
 ...
 ...
 ...
 ...
 Temperature 10
 Gain 10

Process Fluid (Level only)

 Process Fluid

Change Process Fluid

 Temperature Compensation
 Density Table

Density Table

 Temperature 1
 Density 1
 Temperature 2
 Density 2
 ...
 ...
 ...
 ...
 Temperature 10
 Density 10

Temperature Compensation

 Temperature Input
 Temperature For Compensation
  (Visible if Temperature
 Input = None only)

Upper Fluid

 Fluid Name
 Density in Use

Lower Fluid

 Fluid Name
 Density in Use

Temperature Compensation

 Temperature Input
 Temperature For Compensation
  (Visible if Temperature
  Input = None only)

Process Fluid

 Fluid Name
 Density in Use

Upper Fluid Density Table
Lower Fluid Density Table

 Temperature 1
 Density 1
 Temperature 2
 Density 2
 ...
 ...
 Temperature 10
 Density 10

Manual Setup

Overview

DLC3020f Digital Level Controller

DLC3020f Digital Level Controller

Italics text

= Method

Density Tables

 Upper Fluid Density Table
 Lower Fluid Density Table 

www.Fisher.com

For the telephone number of the Emerson Process
Management sales office nearest you, contact:

In North America

Fisher Controls International LLC
1 (641) 754‐3011

In Latin America

Fisher Controls International LLC
1 (314) 746‐9900

In Asia Pacific

Emerson Process Management
Asia Pacific Private Ltd.
(65) 6777‐8211

In Europe

Emerson Process Management Ltd.
+44 1634 895800

For equipment service or support needs, contact
your local Emerson Process Management sales office

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Emerson Models