Page 2 - WARNING
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to pre...
Page 3 - Tools Needed for Assembly; Installed Wire Length; Unpacking Instructions; base bulbs
3 THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Do not install or use fan if any part i...
Page 5 - General; Figure 1
5 Your new ceiling fan will require agrounded electrical supply line of 120 voltsAC, 60 Hz, 15 amp circuit. The outlet box must be securely anchoredand capable of withstanding a load of atleast 50 pounds. General Your Emerson ceiling fan comes suppliedwith a Fan/Light Remote Control whichconsists of...
Page 6 - Figure 2; Figure 3
6 2. Loosen setscrew in motor coupling ifnecessary. Separate, untwist andunkink the three 80” motor leads. Routethe motor lead wires through thedownrod. Align the clevis pin holes inthe downrod with the holes in the motorcoupling. Install the clevis pin andsecure with the hairpin clip (Figure 2).The...
Page 7 - Figure 6
7 PARTIALLY ASSEMBLED FAN SOLIDSTYROFOAMFACING OUT 6" - 8"GAP Figure 5 CEILING COVER PIN DOWNROD HANGER BALL SETSCREW Figure 4 SLIDE FAN BLADE INTO CENTER SLOT FAN BLADE M5 x 12mm WASHER HEAD BLADE SCREWS (3 per blade) CENTER SLOT FAN HOUSING Figure 6 M4 x 10mm SERRATED HEAD SCREW (3) LOWER ...
Page 8 - Figure 8
1. Securely attach the hanger bracket tothe outlet box using the two screwssupplied with the outlet box (Figure 11). How to Hang Your Ceiling Fan The fan must be hung with at least 7' ofclearance from floor to blades (Figure 10). ! WARNING The outlet box and joist must be securelymounted and capable...
Page 9 - How to Wire
9 2. Carefully lift the fan and seat thehanger ball/downrod assembly on thehanger bracket that was just attachedto the outlet box (Figure 12). Be surethe groove in the ball is lined up withthe tab on the hanger bracket(Figure 11). Hanger bracket must seat firmly againstoutlet box. If the outlet box ...
Page 13 - Installation of Storage
13 Figure 19 UL Model No.: CF930 Your remote control has full control of yourfan and light (Figure 19). NOTE: Prior to operation of the fan andlight from the remote control, set thefan speed to HIGH (....) and turn thelight ON ( ). 1. To set the desired fan speed, hold theFAN ( ) button down, then p...
Page 14 - IMPORTANT CARE INSTRUCTIONS; Accessories; Fan/Light Fails to Operate; • Check that the speed switch on the; Short Range; • If the remote control operates the; Trouble Shooting
1. Downrod Extension Kits (see store orcatalog). 2. Ceiling Fan Controls (see store orcatalog). 3. Blades (see store or catalog). 4. Down Light Cover Plate (for use whendown light is not desired) (see store orcatalog). 14 Do not use water when cleaning yourceiling fan. It could damage the motor orth...
Page 15 - Trouble Shooting Ceiling Fan; TROUBLE; Make sure; FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
15 UL Model No.: CF930 Trouble Shooting Ceiling Fan TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connec...
Page 16 - Repair Par ts; HOW TO ORDER REPAIR PARTS
16 Repair Par ts 6 14 10 9 1 8 3 2 7 15 5 4 20 19 13 17 12 12 11 21 22 16 18 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: The model number of your Fan will be found on a labe...
Page 17 - Lockwasher, External Tooth; Repair Par ts Listing
17 Part Numbers Key Model No. Model No. Model No. No. Description CF930BS02 CF930ORB02 CF930WW02 * Hanger Pack, Consisting of: 761655-17 761655-32 761655 1 Hanger Bracket Assembly (1) — — — 2 Hanger Ball (1) — — — 3 Downrod (1) — — — * Parts Bag, Containing: 763280 763280 763280 4 Pin, Clevis (1) — ...
Page 18 - INSTRUCTION TO THE USER; Reorient or relocate the receiving antenna.
18 UL Model No.: CF930 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interfe...
Page 19 - LIMITED WARRANTY; What The Warranty Covers:; authorized service center.; How State Law Relates To The Warranty:
19 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceilingfan against all defects in workmanship and materials. You must be the original purchaser or user of the productto be covered. What The Period Of C...
Page 20 - Air Comfort Products; DIVISION OF EMERSON ELECTRIC CO.
Part No. F40BP73320002 Printed in China 09/10 Form No. BP7332-2 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 UL Model No.: CF930 BP7332-2 CF930 Atomical 9/23/10 3:29 PM Page 20