Emerson AE4-1395- Manual
Emerson AE4-1395– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Application Engineering; Copeland Scroll; DANGER; NOTICE; CAUTION
- Page 3 – ELECTRICAL SHOCK HAZARD; WARNING
- Page 5 – A high pressure control must be used in all
- Page 6 – POE must be handled carefully and the proper
- Page 7 – For OEMs that choose their own controls; Oil Level Verification
- Page 8 – Retrofit Applications To Avoid; equipment modifications.; Performance Modeling; System Modifications; being considered for the digital scroll retrofit,; Disconnect and lockout the power supply.
- Page 9 – The above procedures for changing the
- Page 12 – Figure 1
- Page 13 – Figure 3; Removable External; 0 Frame Digital Scroll
- Page 14 – Figure 5
- Page 15 – Figure 7; 5 Second Operating Cycle
- Page 16 – Figure 8; Arrow on valve
- Page 17 – Modulation Troubleshooting
1
© 2012 Emerson Climate Technologies, Inc.
Printed in the U.S.A.
AE4-1395
Application Engineering
B
U
L
L
E
T
I
N
3 to 15 Ton Copeland Scroll Digital
™
Compressors for Air Conditioning
AE4-1395
August 2012
Application Engineering
B
U
L
L
E
T
I
N
Safety
Safety Instructions ................................................. 2
Safety Icon Explanation ........................................ 2
Instructions Pertaining to Risk of
Electrical Shock, Fire, or Injury to Persons ........... 3
Safety Statements ................................................. 3
I
ntroduction
Nomenclature ....................................................... 4
Digital Compressor Operation .............................. 4
How It Works ....................................................... 4
Application Considerations
Operating Envelope .............................................. 4
Solenoid Valve and Coil ........................................ 5
Pressure Fluctuations ........................................... 5
Piping .................................................................... 5
Start Up and Shut Down ....................................... 5
Compressor Cycling .............................................. 5
Sound Characteristics ........................................... 5
Internal Pressure Relief (IPR) Valve ...................... 5
High Pressure Control ........................................... 5
Low Pressure Control ............................................ 5
Scroll Temperature Protection ............................... 6
Crankcase Heaters ............................................... 6
Oil Type and Oil Removal ..................................... 6
Power Factor ......................................................... 6
Tandem Applications ............................................. 6
Modulation Control ................................................ 7
Application Tests
Oil Level Verification .............................................. 7
Excessive Liquid Floodback Tests ......................... 7
Operating Envelope Tests ..................................... 7
Digital Compressor Retrofit Applications
Reasons to Retrofit ................................................. 7
Retrofit Applications To Avoid .................................. 8
Performance Modeling ............................................ 8
System Modifications .............................................. 8
Compressor Selection & Change-Out ................... 8
Refrigerant Flow Control ....................................... 9
Evaporator Air Flow ............................................... 9
Condenser Air Flow ............................................... 9
Modulation Control ................................................ 9
Assembly Line Procedures
3 To 7.5 Ton Modulation Valve Brazing Procedure ... 9
Pressure Testing ...................................................... 9
Service Procedures
Modulation Troubleshooting ................................... 10
3 to 7.5 Ton Modulation Valve Replacement
Procedure ............................................................... 10
8 To 15 Ton Modulation Valve Replacement
Procedure ............................................................... 10
Scroll Compressor Functional Check ..................... 11
Figures & Tables
Digital Cycle Example ............................................ 12
3 to 7.5 Ton Digital Scroll Cross Sectional View ..... 12
8 to 15 Ton Digital Scroll Cross Sectional View ...... 13
3-7.5 Ton Operating Envelope ................................ 14
8-15 Ton Operating Envelope ................................. 14
Compressor Capacity Graph .................................. 15
Discharge Thermistors ........................................... 15
3 to 7.5 Ton Modulation Valve Piping ..................... 16
3 To 7.5 Ton Tandem .............................................. 16
Modulation Troubleshooting ................................... 17
Copeland Scroll Digital Family Features ................ 18
Refrigerant Charge Limits ...................................... 18
Torque Values ......................................................... 18
Compressor Accessories ....................................... 19
TABLE OF CONTENTS
Section Page Section Page
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Emerson AE4-1395
Summary
2 © 2012 Emerson Climate Technologies, Inc. Printed in the U.S.A. AE4-1395 Application Engineering B U L L E T I N Safety Instructions Copeland Scroll ™ compressors are manufactured according to the latest U.S. and European Safety Standards. Particular emphasis has been placed on the user's safety. ...
3 © 2012 Emerson Climate Technologies, Inc. Printed in the U.S.A. AE4-1395 Application Engineering B U L L E T I N ELECTRICAL SHOCK HAZARD • Disconnect and lock out power before servicing. • Discharge all capacitors before servicing. • Use compressor with grounded system only. • Molded electrical pl...
5 © 2012 Emerson Climate Technologies, Inc. Printed in the U.S.A. AE4-1395 Application Engineering B U L L E T I N Compressor operation during the loaded state should always be inside of the envelope. The envelopes represent allowable operation of the compressor with 20F° suction superheat at rated ...