Emerson ADTS - Manual

Emerson ADTS

Emerson ADTS – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
Page: / 13

Table of Contents:

  • Page 2 – Catalog Number Identification
  • Page 3 – Wiring Diagram
  • Page 4 – INSTALLATION; Controller Ground; When normal
  • Page 5 – Do these checks in the order presented; – Manual Operation Test; for maintenance purposes only; OPEN
  • Page 8 – Verify that the maintenance handle has been; Now continue to; – Voltage Checks
  • Page 9 – Verify that the feeders have been; Refer to Section 3 of the Group 5 Controller; Lamp Test; button to verify that all five
  • Page 10 – Be sure to close the enclosure door; User Controls Locked; How to unlock the User Controls; Transfer Test
  • Page 11 – SECTION 2 TESTING & SERVICE; TRANSFER TEST; Electrical Operation Transfer; PREVENTIVE MAINTENANCE; In the United States; DISCONNECTING THE CONTROLLER
  • Page 12 – MANUAL LOAD TRANSFER; Manual Operation
  • Page 13 – INDEX; Controller User’s Guide
Loading the manual

381333–272 B

50 Hanover Road, Florham Park, New Jersey 07932–1591 USA

For sales or service call 1 800 800–2726 (ASCO) www.ascopower.com

ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3

telephone 519 758–8450, fax 519 758–0876, for service call 1 888 234–2726 (ASCO) www.asco.ca

Operator’s

Manual

4000 Series ADTS

Automatic Delayed–Transition Transfer Switches

J–design 150–600A, H–design 800–1200A,

G–design 1600–3000A, F–design 4000A

DANGER is used in this manual to warn of high

voltages capable of causing shock, burns, or death.

WARNING is used in this manual to warn

of possible personal injury.

CAUTION is used in this manual to warn

of possible equipment damage.

Refer to the outline and wiring drawings provided

with your 4000 Series ADTS for all installation and

connection details and accessories.

Refer to

Group 5 Controller User’s Guide

381333–126

for ATS status display messages, time delays, pickup

& dropout settings, and adjustments.

An ex perienced licensed electrician must install the ACTS.

Rating Label

Each automatic closed–transition transfer switch contains a

rating label to define the loads and fault circuit withstand /

closing ratings. Refer to the label on the transfer switch for

specific values.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury

or serious equipment damage.

Nameplate

The Transfer Switch nameplate includes data for each

specific 4000 Series ADTS. Use the switch only within the

limits shown on this nameplate. A typical Catalog Number

is shown on the next page with its elements explained.

TABLE OF CONTENTS

section-page

INSTALLATION

1-1

. . . . . . . . . . . . . . . . . . . . . . . .

Mounting and Line Connections

1-1

. . . . . . . . .

Auxiliary Circuits and Harness

1-2

. . . . . . . . . . .

Engine Starting Contacts

1-2

. . . . . . . . . . . . . . .

Functional Test

1-3 through 1-8

. . . . . . . . . . . . . .

TESTING & SERVICE

2-1

. . . . . . . . . . . . . . . . . .

Transfer Test

2-1

. . . . . . . . . . . . . . . . . . . . . . . . . .

Preventive Maintenance

2-1

. . . . . . . . . . . . . . . .

Disconnecting the Controller

2-1

. . . . . . . . . . . .

Manual Load Transfer

2-2

. . . . . . . . . . . . . . . . . .

Trouble-Shooting

2-2

. . . . . . . . . . . . . . . . . . . . . .

INDEX

back cover

. . . . . . . . . . . . . . . . . . . . . . . . .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Catalog Number Identification

Catalog Number Identification Typical 4000 Series catalog no. for J–design, 2 pole, 260 amp, 240 V, ADTS in Type 1 enclosure: 4ADTS A 2 260 F 5 C Phase Poles Neutral A – solid Amperes Voltage Controller Enclosure B – switched 5X – if accessoriesordered 5 – standard G – type 4 C – type 1 F – type 3R ...

Page 3 - Wiring Diagram

SECTION 1 INSTALLATION 1 --- 1 ASCO 4000 Series Automatic Delayed–Transition Trans-fer Switches are factory wired and tested. Field installa-tion simply requires mounting and connection of servicecables, and auxiliary control circuits (if required). Remove the Shipping Skid For large switches, open ...

Page 4 - INSTALLATION; Controller Ground; When normal

INSTALLATION (continued) 1 --- 2 Controller Ground A grounding wire must be connected to the controller’slower left mounting stud. Because the controller ismounted on the enclosure door, a conductive strap mustbe used between the enclosure and the door. Thisconnection provides proper grounding which...

Other Emerson Models