  • Page 3 – Catalog Number Identification; Typical 7000 Series ATB catalog no. for overlapping
  • Page 5 – SECTION 1 INSTALLATION; Remove the Shipping Skid; To prevent serious damage, remove 3 shipping; remove 3 or 4 shipping brackets ( L–angles)
  • Page 6 – INSTALLATION; Wiring Diagram
  • Page 7 – Functional Test; Wiring Diagrams; Section 3; – Voltage Checks; Use extreme caution when using a meter
  • Page 8 – – Electrical Operation; Transfer Test; Isolation Handle
  • Page 9 – SECTION 2 TESTING & SERVICE; TRANSFER TEST; Electrical Operation – Transfer; PREVENTIVE MAINTENANCE; Return to Service
  • Page 10 – MANUAL LOAD TRANSFER; CLOSED; MAINTENANCE HANDLE
  • Page 11 – SECTION 3 BYPASSING & ISOLATING; You can only bypass to the same source; To Bypass Normal Source*; ISOLATING
  • Page 12 – BYPASSING & ISOLATING; ISOLATING THE ATS; BYPASSING; TEST
  • Page 13 – Drawout procedure
  • Page 14 – RETURN TO SERVICE; NOTE
  • Page 15 – To Un–Bypass Normal Source*
  • Page 16 – INDEX; Controller User’s Guide
Loading the manual

381333–132 F

50 Hanover Road, Florham Park, New Jersey 07932–1591 USA

For sales or service call 1 800 800–2726 (ASCO) www.ascopower.com

ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3

Operator’s

Manual

7000 Series 7ATB

Automatic Transfer &

Bypass–Isolation Switches

G design 1000 through 4000 amp. sizes

DANGER is used in this manual to warn of high

voltages capable of causing shock, burns, or death.

WARNING is used in this manual to

warn of possible personal injury.

CAUTION is used in this manual to

warn of possible equipment damage.

4000 amp. size

Refer to the outline and wiring drawings provided

with your 7000 Series ATB for all installation and

connection details and accessories.

Refer to

Group 5 Controller User’s Guide

381333–126

for ATS status display messages, time delays, pickup

& dropout settings, and adjustments.

An experienced licensed electrician must install the

7ATB.

Rating Label

Each 7000 Series 7ATB contains a rating label to

define the loads and fault circuit withstand/closing

ratings. Refer to the label on the Transfer Switch for

specific values.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury

or serious equipment damage.

Nameplate

The Transfer Switch nameplate includes data for each

specific 7000 Series ATB. Use the switch only within the

limits shown on this nameplate. A typical Catalog

Number is shown below with its elements explained:

TABLE OF CONTENTS

section-page

INSTALLATION
Mounting

1-1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Power Connections

1-2

. . . . . . . . . . . . . . . . . . . .

Engine Starting & Auxiliary Circuits

1-2

. . . . . .

Functional Test

1-3, 1-4

. . . . . . . . . . . . . . . . . . . . .

TESTING & SERVICE
Transfer Test

2-1

. . . . . . . . . . . . . . . . . . . . . . . . . .

Preventive Maintenance

2-1

. . . . . . . . . . . . . . . .

Disconnecting the Controller

2-1

. . . . . . . . . . . .

Manual Load Transfer

2-2

. . . . . . . . . . . . . . . . . .

Trouble-Shooting

2-2

. . . . . . . . . . . . . . . . . . . . . .

BYPASSING & ISOLATING
Bypassing the ATS

3-1

. . . . . . . . . . . . . . . . . . . .

Isolating the ATS

3-2

. . . . . . . . . . . . . . . . . . . . . .

Return to Service

3-3, 3-4

. . . . . . . . . . . . . . . . . . .

INDEX

back cover

. . . . . . . . . . . . . . . . . . . . . . . . .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Catalog Number Identification; Typical 7000 Series ATB catalog no. for overlapping

Catalog Number Identification Typical 7000 Series ATB catalog no. for overlapping neutral, 3 pole, 4000 amp., 480 V, in Type 1 enclosure: G7ATB C 3 4000 N 5 C Phase Poles Neutral A – solid Amperes Voltage Controller Enclosure B – switching 5X – if accessoriesordered 5 – standard G – type 4 C – type ...

Page 5 - SECTION 1 INSTALLATION; Remove the Shipping Skid; To prevent serious damage, remove 3 shipping; remove 3 or 4 shipping brackets ( L–angles)

1 --- 1 SECTION 1 INSTALLATION The ASCO 7000 Series Automatic Transfer &Bypass–Isolation Switch (ATB) consists of an upperbypass–isolation switch, a lower transfer switch, amonitoring and transfer controller, and door–mountedcontrols. The ATB is factory wired and tested.Installation requires rem...

Page 6 - INSTALLATION; Wiring Diagram

INSTALLATION (continued) 1 --- 2 De–energize the conductors before making any line or auxiliary circuitry connections. Be sure that Normal and Emergency line connections are in proper phase rotation. Place engine gen- erator starting control in the OFF position. Make sure engine generator is not in ...