Emerson 7000 SERIES 7ADTB - Manual

Emerson 7000 SERIES 7ADTB

Emerson 7000 SERIES 7ADTB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Remove the Shipping Skid; To prevent serious damage, remove three; remove 3 shipping
  • Page 3 – INSTALLATION; Wiring Diagram
  • Page 4 – Functional Test; Wiring Diagrams; Section 3; – Voltage Checks; Use extreme caution when using a meter
  • Page 5 – – Electrical Operation; Transfer Test; automatic; Isolation Handle; TEST; Retransfer Delay Bypass; CONN; Bypass Handle
  • Page 6 – SECTION 2 TESTING & SERVICE; TRANSFER TEST; Engine Control; Auto; Electrical Operation – Transfer; PREVENTIVE MAINTENANCE; lubrication kit; REPLACEMENT PARTS; Return to Service
  • Page 7 – MANUAL LOAD TRANSFER; CLOSED; MAINTENANCE HANDLE
  • Page 8 – SECTION 3 BYPASSING & ISOLATING; You can only bypass to the same source; To Bypass Normal Source*; ISOLATING
  • Page 9 – BYPASSING & ISOLATING; ISOLATING THE ATS; BYPASSING
  • Page 10 – RETURN TO SERVICE; To change the position of transfer switch; NOTE
  • Page 11 – To Un–Bypass Normal Source*
  • Page 12 – INDEX; Controller User’s Guide
Loading the manual

381333–140 B

50 Hanover Road, Florham Park, New Jersey 07932–1591 USA

For sales or service call 1 800 800–2726 (ASCO) www.ascopower.com

ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3

telephone 519 758–8450, fax 519 758–0876, for service call 1 888 234–2726 (ASCO) www.asco.ca

Operator’s

Manual

7000 Series 7ADTB

Automatic Delayed–Transition Transfer

& Bypass–Isolation Switches

G design 1000 through 3000 amp. sizes

DANGER is used in this manual to warn of high

voltages capable of causing shock, burns, or death.

WARNING is used in this manual to warn

of possible personal injury.

CAUTION is used in this manual to warn

of possible equipment damage.

TABLE OF CONTENTS

section-page

INSTALLATION
Mounting

1-1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Power Connections

1-2

. . . . . . . . . . . . . . . . . . . .

Engine Starting & Auxiliary Circuits

1-2

. . . . . .

Functional Test

1-3, 1-4

. . . . . . . . . . . . . . . . . . . . .

TESTING & SERVICE
Transfer Test & Preventive Maintenance

2-1

. .

Trouble-Shooting

2-2

. . . . . . . . . . . . . . . . . . . . . .

BYPASSING & ISOLATING
Bypassing the ATS

3-1

. . . . . . . . . . . . . . . . . . . .

Isolating the ATS

3-2

. . . . . . . . . . . . . . . . . . . . . .

Return to Service

3-3, 3-4

. . . . . . . . . . . . . . . . . . .

INDEX

back cover

. . . . . . . . . . . . . . . . . . . . . . . . .

Refer to the outline and wiring drawings provided

with your 7000 Series ADTB for all installation and

connection details and accessories.

Refer to

Group 5 Controller User’s Guide

381333–126

for ATS status display messages, time delays, pickup

& dropout settings, and adjustments.

An experienced licensed electrician must install the

7ADTB.

Rating Label

Each 7000 Series 7ADTB contains a rating label to

define the load and fault circuit withstand/closing

ratings. Refer to the label on the Transfer Switch for

specific values.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury

or serious equipment damage.

Nameplate

The Transfer Switch nameplate includes data for each

specific 7000 Series 7ADTB Use the switch only

within the limits shown on this nameplate. A typical

Catalog Number is shown below with its elements

explained:

Catalog Number Identification

Typical 7000 Series ADTB catalog no. for switching

neutral, 3 pole, 1600 amp., 480 V, in Type 1 enclosure:

G7ADTB

B

3

1600

N

5

C

Phase Poles

Neutral

A

– solid

Amperes

Voltage

Controller

Enclosure

B

– switching

5X

– if

accessories
ordered

5

– standard

G

– type 4

C

– type 1

F

– type 3R

L

– type 12

3

– three Ø

2

– single Ø

B

120

D

220

A

115

C

208

E

230

K

415

M

460

J

400

L

440

N

480

G

277

F

240

H

380

Q

575

P

550

R

600

1200

2000

1000

1600

blank – none

blank – open type

3000

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Remove the Shipping Skid; To prevent serious damage, remove three; remove 3 shipping

SECTION 1 INSTALLATION 1 --- 1 The ASCO 7000 Series Automatic Delayed–TransitionTransfer & Bypass–Iolation Switch (ADTB) consists ofan upper bypass–isolation switch, a transfer switch, amonitoring and transfer control panel, and door–mounted controls. The ADTB is factory wired andtested. Install...

Page 3 - INSTALLATION; Wiring Diagram

INSTALLATION (continued) 1 --- 2 De–energize the conductors before making any line or auxiliary circuitry connections. Be sure that Normal and Emergency line connections are in proper phase rotation. Place engine gen- erator starting control in the OFF position. Make sure engine generator is not in ...

Page 4 - Functional Test; Wiring Diagrams; Section 3; – Voltage Checks; Use extreme caution when using a meter

INSTALLATION (continued) 1 --- 3 RED RED GREEN GREEN observe these lights AMBER Figure 1-3. Standard controls and indicators. Functional Test Read all instructions on the Wiring Diagrams and labels affixed to the ADTB. Note the control features that areprovided and review their operation before proc...

Other Emerson Models