Table of Contents:
- Page 2 – Specifications
- Page 3 – Description; Principle of Operation; system changes. Simultaneously, the pilot amplifies
- Page 4 – Installation; Only personnel qualified through training and; WARNING
- Page 5 – Overpressure Protection; Startup and Adjustment; Startup; Make final pilot control spring adjustments; Adjustment
- Page 6 – Shutdown; Maintenance; as the disk assembly, orifice, and diaphragm must; Body Area Maintenance Procedures; The disk assembly and orifice can be inspected,
- Page 7 – Replacing the Disk Assembly or Orifice; Note; Inspect and, if necessary, remove the orifice; Replacing the Stem Assembly; evenly to square up the orifice (key 2) and disk; Diaphragm and Spring Case Area
- Page 8 – Pilot; Trim Parts
- Page 9 – Diaphragm Parts; Parts Ordering; When corresponding with your local Sales Office or; Parts List
Type 627F
D101545X012
Instruction Manual
Form 5282
April 2012
www.fisherregulators.com
Type 627F Pilot-Operated
Pressure Reducing Regulator
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion
and/or fire causing property damage and
personal injury or death.
Fisher
®
regulators must be installed,
operated, and maintained in
accordance with federal, state, and
local codes, rules and regulations,
and Emerson Process Management
Regulator Technologies, Inc. (Regulator
Technologies) instructions.
If the regulator vents gas or a leak
develops in the system, service to the
unit may be required. Failure to
correct trouble could result in a
hazardous condition.
Call a gas service person to service
the unit. Only a qualified person must
install or service the regulator.
Introduction
Scope of the Manual
This manual provides instructions for installation,
adjustment, maintenance, and parts ordering
information for the Type 627F regulator.
Figure 1.
Type 627F Pilot-Operated Pressure Reducing Regulators
W5607
W5641
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Type 627F 2 1. The pressure/temperature limits in this Instruction Manual or any applicable standard limitation should not be exceeded. Specifications The Specifications section gives some general specifications for the Type 627F regulator. The nameplates give detailed information for a particular r...
Type 627F 3 Description The Type 627F pilot-operated (Type 6351F pilot) pressure reducing regulator (Figure 1) provides economical, accurate pressure control in a wide variety of applications using pressure factor measurement (fixed factor billing). The regulator can be used with natural gas, air, o...
Type 627F 4 When downstream pressure increases due to lowered demand, greater pressure is registered on the pilot diaphragm and the lever side of the main regulator diaphragm. The pilot closes, and the excess loading pressure bleeds off to downstream, through the pilot restriction. With the lower lo...