Emerson 54ea - Manual

Emerson 54ea

Emerson 54ea – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
Page: / 114

Table of Contents:

  • Page 2 – ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!; WARNING; About This Document; Date
  • Page 4 – MODEL 54eA ANALYZER/CONTROLLER; TABLE OF CONTENTS
  • Page 5 – Section
  • Page 6 – LIST OF FIGURES; LIST OF TABLES
  • Page 7 – SPECIFICATIONS; FEATURES AND APPLICATIONS
  • Page 10 – ORDERING INFORMATION
  • Page 11 – INSTALLATION; UNPACKING AND INSPECTION
  • Page 14 – WIRING; NOTE; Be sure to turn off power to the analyzer before wiring the sensor.
  • Page 22 – DISPLAY AND OPERATION; GENERAL DESCRIPTION; ppm
  • Page 23 – SOFTWARE CONFIGURATION
  • Page 30 – CHANGING ALARM SETPOINTS; Alarm setpoints
  • Page 31 – RANGING THE OUTPUTS; Output 1 setpoints
  • Page 32 – Setpoint
  • Page 33 – TESTING OUTPUTS AND ALARMS; Output setpoints; S i m u l a t i n g o u t p u t 1; Test alarm 1; S i m u l a t i n g a l a r m 1
  • Page 34 – Configure; CHOOSING DISPLAY OPTIONS; Display
  • Page 36 – CHANGING OUTPUT PARAMETERS; Output 1 control
  • Page 37 – Ctrl mode
  • Page 38 – Hold feature setup
  • Page 39 – CHANGING ALARM PARAMETERS; Alarm 1 control
  • Page 40 – Activate
  • Page 42 – Feed limit; F e e d l i m i t a l a r m 1
  • Page 43 – Timer; Interval timer
  • Page 44 – CONFIGURING THE pH MEASUREMENT; pH sensor
  • Page 45 – Diagnostics
  • Page 46 – Temp coeff; Temperature coeff
  • Page 47 – TEMPERATURE COMPENSATION AND TEMPERATURE UNITS; pH
  • Page 48 – Noise rejection; Temperature
  • Page 49 – MAIN SENSOR CALIBRATION PARAMETERS
  • Page 50 – Bar meas; BAROMETRIC PRESSURE
  • Page 51 – Lock all
  • Page 52 – CONTROLLER MODE PRIORITY; TABLE 5-2. Controller Mode Priority Chart
  • Page 53 – CALIBRATION - TEMPERATURE
  • Page 54 – TEMPERATURE CALIBRATION; Adjust temp
  • Page 55 – CALIBRATION - DISSOLVED OXYGEN
  • Page 56 – ZEROING THE SENSOR; Calibrate main sensor
  • Page 57 – CALIBRATING THE SENSOR IN AIR
  • Page 59 – CALIBRATING THE SENSOR AGAINST A STANDARD INSTRUMENT; Calibrate
  • Page 60 – CALIBRATING BAROMETRIC PRESSURE; mm Hg; Standardize
  • Page 61 – CALIBRATION - FREE CHLORINE
  • Page 62 – ZEROING THE SENSOR
  • Page 63 – FULL SCALE CALIBRATION
  • Page 64 – DUAL SLOPE CALIBRATION; Adjust temperature; Calibrate low point
  • Page 65 – Low point
  • Page 66 – CALIBRATION - TOTAL CHLORINE
  • Page 67 – ZEROING THE SENSOR
  • Page 68 – FULL SCALE CALIBRATION
  • Page 69 – DUAL SLOPE CALIBRATION
  • Page 71 – CALIBRATION - MONOCHLORAMINE
  • Page 72 – ZEROING THE SENSOR
  • Page 73 – FULL SCALE CALIBRATION
  • Page 75 – ZEROING THE SENSOR
  • Page 76 – FULL SCALE CALIBRATION
  • Page 78 – Autocal buffer 1
  • Page 79 – Autocal buffer 2
  • Page 80 – Calibrate point 1
  • Page 81 – Calibrate point 2
  • Page 82 – Standardize pH
  • Page 83 – pH SLOPE ADJUSTMENT
  • Page 84 – CALIBRATION - CURRENT OUTPUTS; TRIMMING THE OUTPUTS; Output trim; Trim output 1; Cal point
  • Page 85 – PID AND TPC CONTROL
  • Page 89 – TIME PROPORTIONAL CONTROL
  • Page 90 – TROUBLESHOOTING; TROUBLESHOOTING WHEN A FAULT MESSAGE IS SHOWING
  • Page 92 – TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - OXYGEN
  • Page 98 – TROUBLESHOOTING WHEN NO ERROR MESSAGE IS SHOWING —
  • Page 101 – TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - OZONE
  • Page 103 – TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - pH
  • Page 106 – TROUBLESHOOTING NOT RELATED TO MEASUREMENT PROBLEMS
  • Page 107 – SIMULATING INPUTS - OTHER AMPEROMETRIC MEASUREMENTS
  • Page 109 – SIMULATING TEMPERATURE
  • Page 110 – MEASURING REFERENCE VOLTAGE
  • Page 111 – MAINTENANCE
  • Page 112 – RETURN OF MATERIAL
Loading the manual

Model 54eA

Amperometric HART

®

Analyzer/Controller

Instruction Manual

51-54eA/rev.I
April 2005

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!; WARNING; About This Document; Date

ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products tomeet many national and international standards. Because these instru-ments are sophisticated technical products, you must properly install, use,and maintain them to ensure th...

Page 4 - MODEL 54eA ANALYZER/CONTROLLER; TABLE OF CONTENTS

MODEL 54eA TABLE OF CONTENTS MODEL 54eA ANALYZER/CONTROLLER TABLE OF CONTENTS Section Title Page 1.0 SPECIFICATIONS ................................................................................................... 1 1.1 Features and Applications .......................................................

Page 5 - Section

9.0 CALIBRATION - TOTAL CHLORINE ..................................................................... 60 9.1 Introduction .............................................................................................................. 60 9.2 Zeroing the Sensor ...........................................

Other Emerson Models