Emerson 51000 - Manual
Emerson 51000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Instruction; Baumann
- Page 4 – Table 1. BODY ASSEMBLY PART NUMBERS
- Page 5 – DO NOT TIGHTEN AT THIS; each part is seated properly.; Install packing rings over the stem one at a time.; DO NOT OVER TIGHT EN THE PACKING
- Page 6 – Table 4. TYPE 16 ACTUATOR PART NUMBERS
- Page 7 – Table 5. DIMENSIONS AND WEIGHTS, BODY SUBASSEMBLY
- Page 8 – Table 6. WEIGHTS, ACTUATOR AND INSTRUMENTS ONLY
1
Baumann
™
51000 Series Instructions
Instruction
51.LF:IM
April 2007
INTRODUCTION
The Baumann 51000 series control valve is optimally
designed for demanding low fl ow control and is a
perfect fi t where space is at a premium. This compact
package provides the connection integrity of fl anged
body globe valves while being signifi cantly lighter and
easier to install.
SCOPE OF MANUAL
T h i s i n s t r u c t i o n m a n u a l i n c l u d e s i n s t a l l a t i o n ,
maintenance, and parts information for the 51000
series control valve and type 16 actuator.
No person may install operate or maintain a 51000
series control valve without fi rst being fully trained and
qualifi ed in valve, actuator and accessory installation,
operation and maintenance, and carefully reading and
understanding the contents of this manual. If you have
any questions about these instructions contact your
Fisher
®
sales offi ce before proceeding.
CONTENTS
Introduction.................................................................1
Scope......................................................................1
Safety Precautions..................................................1
Maintenance...............................................................2
Installation...................................................................3
Actuator Removal....................................................3
Plug and Packing Replacement..............................3
Disassembly of Valve..............................................3
Reassembly of Valve...........................................3
Body Assembly Part Numbers...............................4
Type 16 Actuator Part Numbers...........................6
Dimensions and Weights............................................7, 8
Always wear protective gloves,
clothing, and eye wear when
performing any installation operations
to avoid personal injury.
Personal injury or property damage
caused by sudden release of pressure
or bursting of pressure retaining parts
may result if service conditions exceed
those for which the product was
intended. To avoid injury or damage,
provide relief valve for over pressure
protection as required by government
or accepted industry codes and good
engineering practices.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
If installing into an existing application,
also refer to the WARNING at the
beginning of the Maintenance section
in this instruction manual.
This valve is intended for a specifi c
range of pressures, temperatures
and other application specifi cations.
Applying different pressures and
temperatures to the valve could
result in parts damage, malfunction
of the control valve or loss of control
of the process. Do not expose this
product to service conditions or
variables other than those for which
the product was intended. If you
are not sure what these conditions
are you should contact your Fisher
sales offi ce for more complete
specifi cations. Provide the product
serial numbers (shown on the
nameplate) and all other pertinent
information.
NOTE
Neither Emerson
®
, Emerson Process
Management, Fisher
®
, nor any of
their affi liated entities assumes
responsibility for the selection, use
and maintenance of any product.
Responsibility for the selection, use
and maintenance of any product
remains with the purchaser and end-
user.
Baumann
™
51000 Series Low Flow
Control Valve Instructions
:$51,1*
:$51,1*
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Instruction 51.LF:IM April 2007 Baumann ™ 51000 Series Instructions If you move or work on an actuator installed on a valve with loading pressure applied, keep your hands and tools away from the stem travel path to avoid personal injury. Be especially careful when removing the stem connector to re...
4 Instruction 51.LF:IM April 2007 Baumann ™ 51000 Series Instructions KEY NO. DESCRIPTION QTY PART NUMBER 0.25" SS 0.25" N10276 Nickel Alloy 0.5" SS Integral Seat 0.5" N10276 Nickel Alloy Integral Seat 0.5" SS Screwed Seat 0.5" N10276 Nickel Alloy Screwed Seat 1 Body 1 51102 ...
5 Baumann ™ 51000 Series Instructions Instruction 51.LF:IMApril 2007 bonnet - confi rm correct orientation - then secure with hex nuts (7). DO NOT TIGHTEN AT THIS POINT. 6. Install stem guide (8) and packing kit (9) on the plug stem (4) in the proper order as shown in fi gure 3, page 6. 7. Carefully...