Emerson 5081-P-FF/FI - Manual
Emerson 5081-P-FF/FI – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SPECIFICATIONS; SPECIFICATIONS - GENERAL
- Page 3 – WIRING; SENSOR WIRING AND SET-UP; NOTE: REF wire covered with
- Page 4 – FIGURE 3. Wiring Diagram — Sensor with Preamplifier
- Page 5 – WIRING THROUGH A JUNCTION BOX WITH REMOTE PREAMPLIFIER; FIGURE 4. Wiring diagram — sensor Model 381+ with preamplifier
- Page 6 – INSTALLATION; UNPACKING AND INSPECTION
- Page 8 – allation; HAZARDOUS AREA INSTALLATION
- Page 9 – FIGURE 9. FM Intrinsically Safe Inst
- Page 15 – TEX Intrinsically Safe Inst
- Page 17 – Uni; LABEL
- Page 18 – EXP PRO; SCH; WI
- Page 21 – Unil
- Page 23 – ROSEMOUNT ANALYTICAL; II
- Page 25 – INFRARED REMOTE CONTROLLER; Infrared Remote Controller.; and; I R C - I N F R A R E D R E M O T E C O N T R O L
- Page 26 – START-UP CONFIGURATION AND CALIBRATION — pH; To perform a two-point buffer calibration, follow these steps:; MENU; PROMPT; FIGURE 14. Menu Tree for pH; SoFt; DIAGNOSE; SLOPE
- Page 27 – START-UP CONFIGURATION AND CALIBRATION — ORP; To perform a one point standardization, follow these steps.; FIGURE 15. Menu Tree for ORP
- Page 28 – MENU MNEMONICS; MANUAL TEXT; PROGRAM MENU MNEMONICS; ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE; Specifications subject to change without notice.; Emerson Process Management
Model 5081-P-FF/FI
F
OUNDATION
®
Fieldbus Two-Wire pH/ORP
Transmitter
Instruction Sheet
PN 51A-5081P-FF-FI/rev.E
January 2011
ESSENTIAL INSTRUCTIONS
READ THIS PAGE BEFORE PROCEEDING!
Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your
particular application. These instruments have been designed, and tested to meet many national and interna-
tional standards. Experience indicates that its performance is directly related to the quality of the installation
and knowledge of the user in operating and maintaining the instrument. To ensure their continued operation to
the design specifications, personnel should read this manual thoroughly before proceeding with installation,
commissioning, operation, and maintenance of this instrument. If this equipment is used in a manner not speci-
fied by the manufacturer, the protection provided by it against hazards may be impaired.
• Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life;
personal injury; property damage; damage to this instrument; and warranty invalidation.
• Ensure that you have received the correct model and options from your purchase order. Verify that this man-
ual covers your model and options. If not, call 1-800-854-8257 or 949-757-8500 to request correct manual.
• For clarification of instructions, contact your Rosemount representative.
• Follow all warnings, cautions, and instructions marked on and supplied with the product.
• Use only qualified personnel to install, operate, update, program and maintain the product.
• Educate your personnel in the proper installation, operation, and maintenance of the product.
• Install equipment as specified in the Installation section of this manual. Follow appropriate local and national
codes. Only connect the product to electrical and pressure sources specified in this manual.
• Use only factory documented components for repair. Tampering or unauthorized substitution of parts and
procedures can affect the performance and cause unsafe operation of your process.
• All equipment doors must be closed and protective covers must be in place unless qualified personnel are
performing maintenance.
• If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against
hazards may be impaired.
For additional information, please visit our website
at
www.emersonprocess.com/raihome/liquid/
.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MODEL 5081-P-FF/FI SPECIFICATIONS SPECIFICATIONS - GENERAL Housing: Cast aluminum with epoxy coating. NEMA 4X (IP65) and NEMA 7B. Neoprene O-ring cover seals. Dimensions: 6.3 in. x 6.9 in. x 6.4 in. (160 mm x 175 mm x 161 mm); diameter 6.1 in (155 mm) Conduit Openings: 3/4 in. FNPT Reference Impedan...
3 MODEL 5081-P-FF/FI WIRING SENSOR WIRING AND SET-UP Wire sensor per Figure 1. Refer to the sensor instructionmanual for more details. If your sensor has an integral preamplifier or you are usinga remote preamplifier, you will need to change the pream-plifier location in the program menu. Please see...
4 MODEL 5081-P-FF/FI WIRING FIGURE 2. Exploded View of Model 5081-P-FF/FI FIGURE 3. Wiring Diagram — Sensor with Preamplifier DWG. NO. REV. 45081P30 A