Emerson 400A - Manual

Emerson 400A

Emerson 400A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 3 – Nameplate and Catalog Number Identification
  • Page 5 – Supporting Foundation; NOTICE; Line Connections; ampere transfer switches.; Testing Power Conductors
  • Page 6 – INSTALLATION; Engine Starting Contacts; When normal source; Controller Ground; Section 5, Control Features; Connections to Controller for other Control Features
  • Page 7 – – Manual Operation Test; – Voltage Checks; Figure 1-4. Removable maintenance handle on
  • Page 8 – Use extreme caution when using a meter to; – Electrical Operation
  • Page 9 – Close the transfer switch enclosure door and; Transfer Test; automatic
  • Page 10 – Figure 2–1. Membrane controls and indicator lights.; SECTION 2 SEQUENCE OF OPERATION; Transfer To Emergency
  • Page 11 – SECTION 3 TESTING & SERVICE; PREVENTIVE MAINTENANCE; Operate the switch at least once a month; Transfer Switch Test; Checklist for Yearly Inspection; Hazardous voltage capable of causing shock,; Clean the enclosure; Check the transfer switch contacts; DISCONNECTING THE CONTROLLER; Disconnecting the Plugs; Section 1; Bypass Time Delay
  • Page 12 – MANUAL LOAD TRANSFER; Manual Operation Test; Section 5; PROBLEM; Trouble-Shooting the Motor Load Transfer Feature
  • Page 13 – SECTION 4 ADJUSTMENTS; Time Delay Adjustment; Shaded DIP switches are standard factory settings).
  • Page 14 – ADJUSTMENTS; How to Change a Setting; off; Close the transfer switch enclosure door.
  • Page 15 – SECTION 5 CONTROL FEATURES – ENGINE EXERCISERS; push button is pressed (and; Shaded DIP switches are standard factory settings.; Select below either; NOTE
  • Page 16 – CONTROL FEATURES; Optional Accessory 11BG – SOURCE AVAILABILITY SIGNAL; Source; Programmable Engine Exerciser
  • Page 17 – Every
  • Page 18 – INPHASE MONITOR; Note; LOAD DISCONNECT FEATURE; Delay After Transfer*; REMOTE CONTROL FEATURES
  • Page 19 – Turn the thermostat’s dial to required setting as shown.; AVAILABLE KITS; Controls
  • Page 20 – INDEX; see
Loading the manual

381333–067 K

50 Hanover Road, Florham Park, New Jersey 07932–1591 USA

For sales or service call 1 800 800–2726 (ASCO) www.ascopower.com

ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3

Operator’s

Manual

Series 300

Automatic Transfer Switches

E–design, 260 and 400 A

DANGER is used in this manual to warn of a

hazardous situation which, if not avoided, will

result in death or serious injury.

WARNING is used in this manual to warn of a

hazardous situation which, if not avoided, could

result in death or serious injury.

CAUTION is used in this manual to warn of a

hazardous situation which, if not avoided, could

result in minor or moderate injury.

Refer to the outline and wiring drawings provided with

your ASCO Series 300 ATS for all installation details.

Rating Label

Each automatic transfer switch contains a rating label to

define the loads and fault circuit withstand / closing ratings.

Refer to the label on the transfer switch for specific values.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury or

serious equipment damage.

An experienced licensed electrician must install the

Automatic Transfer Switch (ATS).

TABLE OF CONTENTS

section-page

INSTALLATION

1-1

. . . . . . . . . . . . . . . . . . . . . . . .

Mounting and Line Connections

1-1

. . . . . . . . .

Engine Starting Contacts

1-2

. . . . . . . . . . . . . . .

Input / Output Label

1-2

. . . . . . . . . . . . . . . . . . . .

Functional Test

1-3, 1-4, 1-5

. . . . . . . . . . . . . . . . .

SEQUENCE OF OPERATION

2-1

. . . . . . . . . . .

TESTING & SERVICE

3-1

. . . . . . . . . . . . . . . . . .

Preventive Maintenance

3-1

. . . . . . . . . . . . . . . .

Transfer Test

3-1

. . . . . . . . . . . . . . . . . . . . . . . . . .

Disconnecting the Controller

3-1

. . . . . . . . . . . .

Manual Load Transfer

3-2

. . . . . . . . . . . . . . . . . .

Trouble-Shooting

3-2

. . . . . . . . . . . . . . . . . . . . . .

ADJUSTMENTS

4-1

. . . . . . . . . . . . . . . . . . . . . . .

Time Delay and Sensor Adjustments

4-1

. . . . .

How to Change a Setting

4-2

. . . . . . . . . . . . . . .

CONTROL FEATURES

5-1

. . . . . . . . . . . . . . . . .

Engine Exercisers

5-1, 5-2, 5-3

. . . . . . . . . . . . . .

Motor Load Transfer

5-4

. . . . . . . . . . . . . . . . . . .

Load Disconnect & Remote Control

5-4

. . . . . .

INDEX

back of manual

. . . . . . . . . . . . . . . . . . . . .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Nameplate and Catalog Number Identification

Nameplate and Catalog Number Identification The Transfer Switch nameplate includes data for each specific ASCO Series 300 ATS. Use the ATS only within the limits shown on this nameplate. A typical Catalog Number is shown below with its elements explained.The example is for a Series 300 ATS with swit...

Page 5 - Supporting Foundation; NOTICE; Line Connections; ampere transfer switches.; Testing Power Conductors

SECTION 1 INSTALLATION 1 --- 1 Series 300 Automatic Transfer Switches are factory wired and tested. Installation requires skid removal then secur- ing the enclosure to the supporting foundation. Supporting Foundation The supporting foundation for the enclosure must belevel and straight. Refer to the...

Page 6 - INSTALLATION; Engine Starting Contacts; When normal source; Controller Ground; Section 5, Control Features; Connections to Controller for other Control Features

INSTALLATION (continued) 1 --- 2 Engine Starting Contacts The engine control contact connections are located onthe transfer switch. Connect signal wires to appropriate term– inals as specified in Table A, shown in Figure 1–2. Table A. Engine start connections. When normal source fails Terminals on t...