Emerson 369P - Manual
Emerson 369P – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Instruction Sheet; A pH glass electrode does have a limited shelf life of one year.; Note
- Page 3 – July 2013; ORP Calibration; Remove the sensor from the buffer, rinse, and install in the process.; Maintenance for ORP Electrode; pH 4 Solution; Installation; Figure 1. Dimensional Drawing
- Page 4 – Figure 2. Flow Through and Insertion Installation
- Page 5 – Figure 5. Wiring 81 through Remote Junction Box
- Page 7 – Figure 10. Wiring 2081 through Remote Junction Box
- Page 9 – Figure 14. Wiring 54 through Remote Junction Box
- Page 36 – Figure 67. Wiring Details of 396PVP Gray Cable for use with 6081
- Page 39 – Part; Accessories
Instruction Sheet
TUpH 396P and 396PVP Sensors
LIQ_MAN_ABR_396P_396PVP
July 2013
Submersion/Insertion pH/ORP Sensors
Specifications
Sensor Type:
TUpH 396P, 396 PVP; GPLR hemi or
flat glass
Range:
*pH: 0–14
ORP:
-1500 to 1500 mv
Percent Linearity*
pH Range
GPLR hemi bulb
GPLR flat bulb
0 – 2 pH
94%
–
2 – 12 pH
97%
98%
12 – 13 pH
98%
95%
13 – 14 pH
98%
–
Pressure Range-Hemi bulb:
100–1136 kPa [abs]
(0–150 psig)
Temperature Range
: 0–100 °C (32-212 °F)
Pressure Range-Flat bulb:
100–790 kPa [abs]
(0–100 psig)
Minimum Conductivity:
75 µS/cm, min; 100 µS/cm
nominal
Flow Rate:
up to 2 ft/sec
Wetted Materials:
Titanium, Polypropylene, EPDM,
glass; platinum (ORP only)
Process Connection:
1 in. MNPT front and rear
facing threads
Integral Cable:
396P: (-01) -25 ft; (02) -15 ft coaxial
VP8 Cable:
use PN 24281-00 15ft VP8 cable
Preamplifier Options:
396P: Remote or Integral SMART (-01)
396PVP: Remote or Integral SMART (-70)
Weight/Shipping Weight:
0.45 kg/0.9 kg (1 lb/2 lb)
WARNING
Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process
temperature is lowered to a safe level!
WARNING
Glass electrode must be wetted at all times (in storage and in line) to maximize sensor life.
CAUTION
SENSOR/PROCESS APPLICATION COMPATIBILITY
The wetted sensor materials may not be compatible with process com position and operating conditions. Application
compat ibility is entirely the responsibility of the user.
CAUTION
The buffer in the protective boot may cause skin or eye irritation.
ATEX DIRECTIVE
Special Conditions for safe use
1. All pH/ORP sensors have a plastic enclosure which must only be cleaned with a damp cloth to avoid the danger due to a
build up of an electrostatic charge.
2. All pH/ORP sensor Models are intended to be in contact with the process fluid and may not meet the 500V r.m.s. a.c. test
to earth. This must be taken into consideration at installation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 TUpH 396P and 396PVP Sensors Instruction Sheet July 2013 LIQ_MAN_ABR_396P_396PVP Storage 1. It is recommended that electrodes be stored in their original shipping containers until needed. 2. Do not store at temperatures below -5 °C (23 °F). 3. Electrodes should be stored with a protective cap cont...
3 Instruction Sheet TUpH 396P and 396PVP Sensors LIQ_MAN_ABR_396P_396PVP July 2013 ORP Calibration 1. After making an electrical connection between the sensor and the instrument, obtain a standard solution of saturated quinhydrone. This can also be made quite simply by adding a few crystals of quinh...
4 TUpH 396P and 396PVP Sensors Instruction Sheet July 2013 LIQ_MAN_ABR_396P_396PVP Figure 2. Flow Through and Insertion Installation Figure 3. Wiring for 81 Figure 4. Wiring for 1181