- Page 3 – Nameplate; The Transfer Switch nameplate includes data for; Catalog Number Identification; A typical Catalog Number is shown below with its
- Page 5 – NOTICE
- Page 6 – INSTALLATION; Engine Starting Contacts; When normal; Auxiliary Circuits; Section 5, Control Features; Connections to Controller
- Page 7 – – Manual Operation Test; ATS Position; – Voltage Checks
- Page 8 – First check nameplate on transfer switch rated voltage; Use extreme caution when using a meter to; * If necessary, adjust voltage regulator on the; – Electrical Operation
- Page 9 – Close the transfer switch enclosure door and; Transfer Test; automatic
- Page 10 – Figure 2–1. Membrane controls and indicator lights.; SECTION 2 SEQUENCE OF OPERATION; Transfer To Emergency
- Page 11 – SECTION 3 TESTING & SERVICE; PREVENTIVE MAINTENANCE; Operate the switch at least once a month; Transfer Switch Test; Checklist for Yearly Inspection; Hazardous voltage capable of causing shock,; Clean the enclosure; De–energize all sources,; Check the transfer switch contacts; DISCONNECTING THE CONTROLLER; Disconnecting the Plugs; Section 1; Bypass Time Delay
- Page 12 – MANUAL LOAD TRANSFER; Manual Operation Test; Section 5; PROBLEM; Trouble-Shooting the Motor Load Transfer Feature
- Page 13 – SECTION 4 ADJUSTMENTS; Time Delay Adjustment; Shaded DIP switches are standard factory settings).
- Page 14 – ADJUSTMENTS; How to Change a Setting; off; Close the transfer switch enclosure door.
- Page 15 – SECTION 5 CONTROL FEATURES – ENGINE EXERCISERS; push button is pressed (and; Shaded DIP switches are standard factory settings.; Select below either; NOTE
- Page 16 – CONTROL FEATURES; Optional Accessory 11BG – SOURCE AVAILABILITY SIGNAL; Source; Programmable Engine Exerciser
- Page 17 – Every
- Page 18 – INPHASE MONITOR; Note; LOAD DISCONNECT FEATURE; Delay After Transfer*; REMOTE CONTROL FEATURES
- Page 19 – Turn the thermostat’s dial to required setting as shown.; AVAILABLE KITS; Controls
- Page 20 – INDEX; see
381333–289 C
50 Hanover Road, Florham Park, New Jersey 07932–1591 USA
For sales or service call 1 800 800–2726 (ASCO) www.ascopower.com
ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3
Operator’s
Manual
Series 300
Automatic Transfer Switches
J–design, 600 A
DANGER is used in this manual to warn of a
hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING is used in this manual to warn of a
hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION is used in this manual to warn of a
hazardous situation which, if not avoided, could
result in minor or moderate injury.
Refer to the outline and wiring drawings provided with
your ASCO Series 300 ATS for all installation details.
Rating Label
Each automatic transfer switch contains a rating label to
define the loads and fault circuit withstand / closing ratings.
Refer to the label on the transfer switch for specific values.
Do not exceed the values on the rating label.
Exceeding the rating can cause personal injury or
serious equipment damage.
An experienced licensed electrician must install the
Automatic Transfer Switch (ATS).
TABLE OF CONTENTS
section-page
INSTALLATION
1-1
. . . . . . . . . . . . . . . . . . . . . . . .
Mounting and Line Connections
1-1
. . . . . . . . .
Engine Starting Contacts
1-2
. . . . . . . . . . . . . . .
Input / Output Label
1-2
. . . . . . . . . . . . . . . . . . . .
Functional Test
1-3, 1-4, 1-5
. . . . . . . . . . . . . . . . .
SEQUENCE OF OPERATION
2-1
. . . . . . . . . . .
TESTING & SERVICE
3-1
. . . . . . . . . . . . . . . . . .
Preventive Maintenance
3-1
. . . . . . . . . . . . . . . .
Transfer Test
3-1
. . . . . . . . . . . . . . . . . . . . . . . . . .
Disconnecting the Controller
3-1
. . . . . . . . . . . .
Manual Load Transfer
3-2
. . . . . . . . . . . . . . . . . .
Trouble-Shooting
3-2
. . . . . . . . . . . . . . . . . . . . . .
ADJUSTMENTS
4-1
. . . . . . . . . . . . . . . . . . . . . . .
Time Delay and Sensor Adjustments
4-1
. . . . .
How to Change a Setting
4-2
. . . . . . . . . . . . . . .
CONTROL FEATURES
5-1
. . . . . . . . . . . . . . . . .
Engine Exercisers
5-1, 5-2, 5-3
. . . . . . . . . . . . . .
Motor Load Transfer
5-4
. . . . . . . . . . . . . . . . . . .
Load Disconnect & Remote Control
5-4
. . . . . .
INDEX
back of manual
. . . . . . . . . . . . . . . . . . . . .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Nameplate The Transfer Switch nameplate includes data for each specific ASCO Series 300 ATS. Use the ATS only within the limits shown on this nameplate. Catalog Number Identification A typical Catalog Number is shown below with its elements explained. The example is for a Series 300 ATS with switche...
SECTION 1 INSTALLATION 1 --- 1 Series 300 Automatic Transfer Switches are factory wired and tested. Installation requires skid removal then securing the enclosure to the supportingfoundation. Remove the Shipping Skid Open the front door and remove the four lag screws (2 in front, 2 in rear) securing...
terminal block for engine start and auxiliary circuit connections left side of transfer switch COMMON FEATURE 7 closes to start FEATURE 8 opens to start COMMON FEATURE 14B closed on emergency FEATURE 14A closed on normal COMMON FEATURE 14BA closed on emergency FEATURE 14AA closed on normal Engine St...