Emerson 2625NS- User Manual
Emerson 2625NS– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Specifications
- Page 3 – Instruction Manual; Educational Services
- Page 4 – Installation; WARNING; Mounting
- Page 5 – Pressure Connections
- Page 6 – Diagnostic Connections; CAUTION
- Page 7 – Exhaust Ports; Operating Information; Principle of Operation
- Page 8 – Maintenance; Diaphragm Assembly Replacement
- Page 9 – Valve Assembly Replacement
- Page 10 – Installation of Diagnostic Connections
- Page 11 – Parts Ordering; Parts Kits
www.Fisher.com
Fisher
r
2625 and 2625NS Volume Boosters
Contents
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Educational Services
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Connections
. . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Connections
. . . . . . . . . . . . . . . . . . . . . .
Supply Pressure
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exhaust Ports
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Information
. . . . . . . . . . . . . . . . . . . . . . . . .
Principle of Operation
. . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diaphragm Assembly Replacement
. . . . . . . . . . . . .
Valve Assembly Replacement
. . . . . . . . . . . . . . . . . .
Installation of Diagnostic Connections
. . . . . . . . .
Parts Ordering
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Kits
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts List
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. Fisher 2625 Volume Booster
W4727-1
Introduction
Scope of Manual
This instruction manual provides installation, operation, maintenance, and parts information for Fisher 2625 and
2625NS volume boosters (figure 1). Refer to separate instruction manuals for information regarding the valve body,
actuator, and other accessories.
Do not install, operate, or maintain a 2625 or 2625NS volume booster without being fully trained and qualified in
valve, actuator, and accessory installation, operation, and maintenance.
To avoid personal injury or property damage,
it is important to carefully read, understand, and follow all of the contents of this manual, including all safety cautions
and warnings.
If you have any questions regarding these instructions contact your Emerson Process Management sales
office before proceeding.
Description
The 2625 is certified for use in Safety Instrumented System (SIS) applications. Certification is by EXIDA Consulting LLC,
a global provider of functional safety and control system security. SIS certification is identified on the product by the
EXIDA logo on the 2625 nameplate.
The 2625 and 2625NS volume boosters are used in conjunction with a positioner on a throttling control valve to
increase stroking speed. The booster has a fixed deadband (controlled by the seat‐to‐seat dimension of the supply and
Instruction Manual
D100348X012
2625 and 2625NS Volume Booster
January 2015
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instruction Manual D100348X012 2625 and 2625NS Volume Booster January 2015 2 exhaust plugs) which is factory set during assembly and testing. In addition, the booster incorporates soft‐seatconstruction and an integral bypass restriction to eliminate positioner saturation problems that can occur with...
Instruction Manual D100348X012 2625 and 2625NS Volume Booster January 2015 3 Table 1. Specifications Port Diameters (1) Supply Port: J 9.5 mm (0.375 inch) or J 12.7 mm (0.5 inch) Exhaust Port: J 2.4 mm (0.094 inch), J 9.5 mm (0.375 inch) or J 12.7 mm (0.5 inch) Input Signal Positioner output Maximum...
Instruction Manual D100348X012 2625 and 2625NS Volume Booster January 2015 4 Table 2. Maximum Flow Coefficients PORT SIZE COMBINATIONS SUPPLY PORT COEFFICIENTS EXHAUST PORT COEFFICIENTS Supply Port Exhaust Port mm Inch mm Inch C v C v 9.5 0.375 2.49.5 12.7 0.0940.375 0.5 3.743.743.74 0.232.293.40 12...