Emerson 1F82-0261 - Manual
Emerson 1F82-0261 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
EMERSON BLUE 2
”
THERMOSTATS
BLUE 2" THERMOSTATS - 2 SQ. IN. DISPLAY
Heat Pump or Single Stage Models, easy to see Display Characters
Offering a Step up from 70 Series.
FEATURES
• Heat Pump or Single Stage models.
• Programmable, 5/1/1 Day, 24 Hour, 0-Day or Non-Programmable.
• Gas, Oil, Electric, mV.
• Cool Savings™ saves energy during peak A/C demand periods.
• Lighted display for easier low light viewing.
• Dual power - hardwired and/or battery powered.
• Fits horizontal junction box.
• Air filter change indicator option.
SPECIFICATIONS
Electrical Rating:
Hardwire
. . . . . . . . . . . . . . . . . . . . . . .
20-30 VAC, NEC Class II 50/60Hz
Battery Power
. . . . . . . . . . . . . . . . . . . .
mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Terminal Load
. . . . . . . . . . . . . . . . . . . .
1.0 A per terminal,
1.5 A maximum all terminals combined
Setpoint Range
. . . . . . . . . . . . . . . . . . .
45 to 90°F (7 to 32°C)
Rated Differentials, Universal Models: Fast
Med.
Slow
Heat (Single Stage)
. . . . . . . . . . . . . . .
0.8°F
1.2°F
Cool (Single Stage)
. . . . . . . . . . . . . . .
1.2°F
1.7°F
Heat Pump . . . . . . . . . . . . . . . . . . . . . .
1.2°F
1.7°F
Aux./Emer Heat
. . . . . . . . . . . . . . . . . .
0.8°F
1.2°F
Rated Differentials, Single Stage Models: Fast
Med.
Slow
Heat . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.6°F
0.8°F
1.2°F
Cool . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2°F
1.7°F
Heat Pump . . . . . . . . . . . . . . . . . . . . . .
0.8°F
1.2°F
Operating Ambient
. . . . . . . . . . . . . . . .
32 to +105°F (0 to +41°C)
Operating Humidity. . . . . . . . . . . . . . . .
90% non-condensing max.
Shipping Temperature Range
. . . . . . . .
-4 to +150°F (-20 to +65°C)
Dimension. . . . . . . . . . . . . . . . . . . . . . .
3
3
/
4
”
H x 4
3
/
4
”
W x 1
1
/
2
”
D
PARTS AND ACCESSORIES
See end of this section for additional parts and accessories
• F61-2634 — Wallplate 6½
”
W X 5
”
H, for use with or without horizontal junction box
• F61-2648 — Wallplate (6 pack of F61-2634 above)
• Thermostat Guards — see pages 24-25 for quick selection
1F82-0261
1F86-0244
1F86EZ-0251
(coming soon)
1F89EZ-0251
(coming soon)
THERMOST
ATS
www.white-rodgers.com